Mini Incision Dynamic Hip Screw Technique (MIDHST)

February 28, 2017 updated by: Issa, Abdulhamid Sayed, M.D.
Femoral cervical fractures fixation with DHS plate throw 3 cm incision and minimum surgical trauma.

Study Overview

Status

Completed

Detailed Description

This technique is the same of AO Dynamic Hip Screw (DHS) technique using 4 holes plate or smaller, in this case it is enough to make just a 3 cm skin incision over the guide wire that is inserted parallel to the anteversion wire by using the 135° guide fixed on the T-handle; (step 2-2), and continuing AO technique steps, until step 3-4, for the plate assembling we remove the guide wire, and insert the plate sliding it through the skin cut over the femur shaft under the muscles using the plate for dissection the soft tissue above the bone surface non using any tool as periosteal elevator but the plate itself by holding it from its DHS screw canal and in 180 degree rotation position in axial aspect (transvers aspect) using the plate end for soft tissue gentle dissection over the bone, then turning the plate 180 degree over the bone shaft to the right position and sliding the DHS screw plat canal over the DHS screw using the measuring bar. Two skin stitches are enough.

Technique

Step 1-reduction

In many cases the traction table is used. The reduction is done on this table and before the patient is draped. Important also is to guarantee smooth access of the image intensifier in both planes; AP and lateral.

Step 2-guide wire insertion

  1. The anteversion of the femoral neck is determined with a long K-wire inserted with the blunt end first. An alternative is to use a long, non-threaded K-wire.
  2. Under X-ray control, the guide wire is inserted parallel to the anteversion wire by using the 135° guide fixed on the T-handle.

Step 3-screw insertion

  1. The length of the screw must be measured/determined with the guide wire. Note that the screw must be 10 mm shorter than the length of the guide wire. The surgeon will deduct 10 mm of the measured length to determine the screw length.
  2. Set the triple reamer to 10 mm shorter than the measured length. The hole is drilled over the guide wire.
  3. Tapping is only required in young patients with dense bone.
  4. For the plate assembling we remove the guide wire, and insert the plate sliding it through the skin cut over the femur shaft under the muscles using the plate for dissection the soft tissue above the bone surface non using any tool as periosteal elevator but the plate itself by holding it from its DHS screw canal and in 180 degree rotation position in axial aspect (transvers aspect) using the plate end for soft tissue gentle dissection over the bone, then turning the plate 180 degree over the bone shaft to the right position.

    • The plate is slid over the wrench.
    • The DHS screw is attached to the coupling wrench.
    • The sleeve is assembled over the wrench.

Step 4-plate fixation

Impact the plate in order to have best contact with the femur. The plate is fixed with conventional 4.5 mm screws:

  • Drill bit 3.2 mm with sleeve
  • Measuring
  • Tap (when no self-tapping screws are used)
  • Insertion of screw

Study Type

Interventional

Enrollment (Actual)

65

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

21 years to 75 years (Adult, Older Adult)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Patients presented with intertrochanteric hip fractures

Exclusion Criteria:

  • not operative patients

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Abdulhai
One show man technique, it is the same of AO Dynamic Hip Screw (DHS) technique using 4 holes plate or smaller, in this case it is enough to make just a 3 cm skin incision.
This technique is the same of AO Dynamic Hip Screw (DHS) technique using 4 holes plate or smaller, in this case it is enough to make just a 3 cm skin incision over the guide wire that is inserted parallel to the anteversion wire by using the 135° guide fixed on the T-handle; (step 2-2), and continuing AO technique steps, until step 3-4, for the plate assembling we remove the guide wire, and insert the plate sliding it through the skin cut over the femur shaft under the muscles using the plate for dissection the soft tissue above the bone surface non using any tool as periosteal elevator but the plate itself by holding it from its DHS screw canal and in 180 degree rotation position in axial aspect (transvers aspect) using the plate end for soft tissue gentle dissection over the bone, then turning the plate 180 degree over the bone shaft to the right position and sliding the DHS screw plat canal over the DHS screw using the measuring bar. Two skin stitches are enough.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Proportion of patients with post surgical trauma
Time Frame: 12 -14 days for soft tissue healing
mini incision
12 -14 days for soft tissue healing

Secondary Outcome Measures

Outcome Measure
Time Frame
Proportion of patients with cosmetic scar
Time Frame: Up to 6 weeks
Up to 6 weeks

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

June 1, 2010

Primary Completion (Actual)

January 1, 2017

Study Completion (Actual)

January 1, 2017

Study Registration Dates

First Submitted

February 18, 2017

First Submitted That Met QC Criteria

February 28, 2017

First Posted (Actual)

March 3, 2017

Study Record Updates

Last Update Posted (Actual)

March 3, 2017

Last Update Submitted That Met QC Criteria

February 28, 2017

Last Verified

February 1, 2017

More Information

Terms related to this study

Other Study ID Numbers

  • Abdulhai's Technique

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

YES

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Intratrochontric Fracture

Clinical Trials on Mini Incision Dynamic Hip Screw Technique

3
Subscribe