Research on a NTHF to Improve Pulmonary Function in Patients With Respiratory Failure

June 27, 2022 updated by: Shenzhen Second People's Hospital

Research on a New Nursing Model of New High-flow Oxygen Inhalation Device to Improve Pulmonary Function in Patients With Respiratory Failure

Patients with respiratory failure have high morbidity and mortality. Long-term mechanical ventilation causes a high medical burden and cannot cure respiratory failure. Therefore, in-depth research on early weaning and oxygen therapy nursing mode is needed. Currently, studies on artificial airway high-flow oxygen therapy are limited. Studies have reported that oxygen inhalation devices that increase expiratory resistance produce flow-dependent positive airway pressure and lung volume effects that improve oxygenation and ventilation. It means that the innovation of oxygen therapy device may be a change The key to improving lung function and reducing mechanical ventilation in patients with respiratory failure.

The project team is committed to the innovation of high-flow oxygen therapy devices and the research on oxygen therapy care. In the early stage, the "New Artificial Airway High Flow Oxygen Therapy Device" was designed (NTHF), in 2018, the new technology and new projects were declared and approved to solve the problem of the flow rate of oxygen therapy devices. In the pre-test, 78 tracheotomy patients were observed using NTHF and respiratory humidification therapy device (AIRVOTM2 ) with high-flow oxygen therapy. As a result, NTHF was superior to AIRVOTM2 in improving airway humidification, oxygenation effect and cost, and published an article, which was approved in 2019 "Non-inferiority of humidification performance of a novel high-flow oxygen therapy device in oxygen therapy for tracheostomy-off-weaned patients. In 2021, it will be approved for the promotion of appropriate technologies for health and health in Guangdong Province. Relying on the high-level clinical key specialties of Guangdong Province, support with scientific research technology and financial support conditions.

Research hypothesis: NTHF has the physiological effects of increasing the positive expiratory pressure of artificial airway, alveolar ventilation, and humidification, and can improve the lung function of patients with respiratory failure after tracheotomy.

Study Overview

Status

Not yet recruiting

Detailed Description

1.1 Patients with respiratory failure have high morbidity and mortality. Long-term mechanical ventilation causes a high medical burden and cannot cure respiratory failure. Therefore, it is necessary to In-depth study of daily off-line and oxygen therapy nursing mode. Currently, studies on artificial airway high-flow oxygen therapy are limited. Studies have reported that increased expiratory resistance Oxygen inhalation devices produce flow-dependent positive airway pressure and lung volume effects that improve oxygenation and ventilation. It means that the innovation of oxygen therapy device may be a change.The key to improving lung function and reducing mechanical ventilation in patients with respiratory failure.

1.2 The project team is committed to the innovation of high-flow oxygen therapy devices and research on oxygen therapy care. In the early stage, the "New Artificial Airway High Flow Oxygen Therapy Device" was designed (NTHF), in 2018, the new technology and new projects were declared and approved to solve the flow rate problem of oxygen therapy devices ,observing 78 tracheotomized patients using NTHF and respiratory humidification therapy device (AIRVOTM2) Perform high-flow oxygen therapy. As a result, NTHF was superior to AIRVOTM2 in improving airway humidification, oxygenation, and cost, and published an article. Approved in 2019 "New high-flow oxygen therapy device in tracheotomy Non-inferiority study of humidification performance in oxygen therapy for weaned patients" (funded 150,000 yuan, China Clinical Research Registry, ChiCTR1900023421). 2021 , it was approved to promote the "Artificial Airway High Flow Oxygen Therapy Airtight Suction Technology" in Guangdong Province for Health and Health Appropriate Technology . Relying on Guangdong Province High-level clinical key specialties,support with scientific research technology and financial support condition.

1.3 Scientific assumption: NTHF has the physiological effects of increasing positive expiratory pressure of artificial airway, alveolar ventilation, and humidification, and can improve respiratory failure trachea,The patient's lung function was incised.

2 goals 2.1 To evaluate the effect of NTHF on improving pulmonary ventilation, ventilation and defense function in patients with respiratory failure artificial airway.

2.2 Obtain evidence that NTHF improves pulmonary function in patients with respiratory failure, and establish a new model of oxygen therapy nursing for patients with artificial airway in respiratory failure.

3 Research content 3.1 In a randomized parallel control method, NTHF and AIRVOTM2 were used in two groups of patients with respiratory failure artificial airway, and the two groups of patients were observed for 7 days.

The oxygenation index, respiratory rate, and mechanical ventilation time were analyzed, and the improvement of oxygenation in patients with respiratory failure by two oxygen therapy devices was analyzed.

3.2 Comparing the results of pulmonary function tests and microbial metagenomic testing of the two groups of patients before treatment and after 7 days of treatment, to explore the effect of NTHF on improving pulmonary function and patient comfort in patients with mild and moderate respiratory failure, and to explore the effect of NTHF in patients with respiratory failure caused by different diseases. A new model of oxygen therapy care.

4 Key issues to be addressed 4.1 To verify the effect of the new high-flow oxygen therapy device in improving oxygenation, ventilation and humidification of patients with respiratory failure artificial airway.

4.2 To explore whether the new high-flow oxygen therapy device can improve the lung function of patients with respiratory failure artificial airway, and establish a new model of oxygen therapy nursing.

5 Expected results 5.1 Academic indicators: Establish a personalized weaning scheme for patients with respiratory failure and a new nursing model for tracheotomy and high-flow humidified oxygen therapy. Published papers 1-2Participate in academic exchange conferences.

5.2 Talent training: train 1-2 respiratory therapists and graduate students. 5.3 Social and economic benefits: reduce the time of mechanical ventilation in patients with respiratory failure,Shorten the days of hospitalization, reduce costs, and reduce the burden on families and society.

Study Type

Interventional

Enrollment (Anticipated)

138

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

    • Guangdong
      • Shenzhen, Guangdong, China, 518000
        • Shenzhen Second People's Hospital
        • Contact:

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Patient who ≥18 years old and meets the diagnostic criteria for respiratory failure
  2. Have an artificial airway, ready or have been released from the ventilator
  3. The circulation is basically stable, and there are no shocks of various types that are difficult to correct (mean arterial pressure remains unchanged under the condition of vasoactive drugs).

    <65mmHg)

  4. Consciousness and ability to cooperate with clinical treatment

Exclusion Criteria:

  1. Pregnancy and end-stage cancer patients
  2. History of airway injury, pulmonary trauma, and lung surgery
  3. Central respiratory failure or status asthmaticus caused by neurological diseases
  4. Refusing to cooperate with treatment or to participate in the researcher

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Supportive Care
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: new type of tracheotomy high-flow oxygen therapy (NTHF)
NTHF (connect the oxygen suction tube, Venturi, Fisher & Paykel MR850 heated humidifier, RT308 breathing tube with humidification tank, airtight suction tube and tracheotomy in sequence from the output end of the automatic pressure-adjustable oxygen flow meter Catheter), adjust the MR850 to invasive automatic transmission, the temperature sensor automatically adjusts and maintains the gas temperature at the inlet of the tracheostomy catheter at 37°C according to the feedback temperature, and adjusts according to the gas outflow from the exhalation port of the patient's inspiratory phase. The gas flow rate of the oxygen therapy device is 40-60L/min. According to the monitored pulse oxygen saturation (SpO 2 ), the concentration of the venturi valve and the corresponding oxygen flow rate are adjusted to maintain the SpO 2 between 94% and 100%.
From the output end of the automatic pressure-adjustable oxygen flow meter, connect the oxygen suction tube, Venturi, Fisher & Paykel MR850 heated humidifier, RT308 breathing tube with humidification tank, closed sputum suction tube and tracheostomy tube), Adjust the MR850 to invasive automatic transmission, the temperature sensor automatically adjusts and maintains the gas temperature at the inlet of the tracheostomy tube at 37°C according to the feedback temperature, and adjusts the oxygen therapy device according to the gas outflow from the exhalation port of the patient's inspiratory phase. The gas flow rate is 40-60L/min. According to the monitored pulse oxygen saturation (SpO 2 ), the concentration of the venturi valve and the corresponding oxygen flow rate are adjusted to maintain the SpO 2 between 94% and 100%.
Active Comparator: Respiratory Humidification Treatment( AIRVO TM 2)
AIRVOTM 2 (Fisher & Paykel, Auckland, New Zealand), connect the special breathing circuit, tracheostomy joint and tracheostomy tube in sequence from the output end of the oxygen flow meter. The gas outflow from the mouth is the standard, adjust the output gas flow rate of the therapy device to 40-60L/min, adjust the oxygen concentration according to the monitored pulse oxygen saturation (SpO 2 ), and maintain the SpO 2 between 94% and 100%. .
From the output end of the automatic pressure-adjustable oxygen flow meter, connect the oxygen suction tube, Venturi, Fisher & Paykel MR850 heated humidifier, RT308 breathing tube with humidification tank, closed sputum suction tube and tracheostomy tube), Adjust the MR850 to invasive automatic transmission, the temperature sensor automatically adjusts and maintains the gas temperature at the inlet of the tracheostomy tube at 37°C according to the feedback temperature, and adjusts the oxygen therapy device according to the gas outflow from the exhalation port of the patient's inspiratory phase. The gas flow rate is 40-60L/min. According to the monitored pulse oxygen saturation (SpO 2 ), the concentration of the venturi valve and the corresponding oxygen flow rate are adjusted to maintain the SpO 2 between 94% and 100%.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Level of oxygenation
Time Frame: 24hours after start of high flow oxygen therapy
Oxygenation is assessed by arterial blood gas sample
24hours after start of high flow oxygen therapy
Level of oxygenation
Time Frame: 48 hours after start of high flow oxygen therapy
Oxygenation is assessed by arterial blood gas sample
48 hours after start of high flow oxygen therapy
Level of oxygenation
Time Frame: 7th days after start of high flow oxygen therapy
Oxygenation is assessed by arterial blood gas sample
7th days after start of high flow oxygen therapy

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
level of sputum viscosity
Time Frame: 24th, 48th and 7th days after start of high flow oxygen therapy
sputum viscosity is assessed with a sputum viscometer
24th, 48th and 7th days after start of high flow oxygen therapy
Patient satisfaction scoreg greater than or equal to 90
Time Frame: the 7th day after start of high flow oxygen therapy
Using Hospital Designated Satisfaction Questionnaire which include comfort, bloating, dry mouth, ability to hear and speak(Total score is 100 points)
the 7th day after start of high flow oxygen therapy

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Study Chair: MEI YANGMEI, Shenzhen Second People's Hospital

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Anticipated)

July 1, 2022

Primary Completion (Anticipated)

August 1, 2022

Study Completion (Anticipated)

June 30, 2024

Study Registration Dates

First Submitted

May 14, 2022

First Submitted That Met QC Criteria

June 27, 2022

First Posted (Actual)

June 28, 2022

Study Record Updates

Last Update Posted (Actual)

June 28, 2022

Last Update Submitted That Met QC Criteria

June 27, 2022

Last Verified

April 1, 2022

More Information

Terms related to this study

Other Study ID Numbers

  • A2022088

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

No

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Respiratory Insufficiency

Clinical Trials on high-flow oxygen therapy device for tracheotomized patients

3
Subscribe