- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05704426
Arrythmia Burden in Cardiac Contractility Modulation (CCM) (ABC)
Arrhythmia Burden in Patients With Impulse Dynamics Optimizer Cardiac Contractility Modulation (CCM) Device Implantation: Retrospective and Prospective Evaluation
The Impulse Dynamics Optimizer Device is a Food and Drug Administration (FDA) approved; commercially available device indicated for patients with heart failure with reduced ejection fraction (HFrEF). Many candidates of this device have a previously implanted cardiovascular implantable electronic device (CIED)- internal cardioverter defibrillator (ICD) or permanent pacemaker (PM). Patients with heart failure are at high risk for both atrial and ventricular cardiac arrhythmias.
The aim of this study is to evaluate patients for Atrial fibrillation (AF) burden episode data obtained from interrogation of their CIED 8 months or greater after Optimizer implant and compare arrhythmia burden 6 months before Optimizer Cardiac Contractility Modulation (CCM) device insertion to 8 months or greater after Optimizer insertion (after 2 month blanking period).
Study Overview
Status
Conditions
Intervention / Treatment
Study Type
Enrollment (Anticipated)
Contacts and Locations
Study Contact
- Name: Sameer Jamal, MD
- Phone Number: 5519965870
- Email: sameer.jamal@hmhn.org
Study Locations
-
-
New Jersey
-
Hackensack, New Jersey, United States, 07601
- Recruiting
- Hackensack Univeristy Medical Center
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- 1%≤AF burden≤99% in the 6 month period prior to Optimizer implant as documented the patient's CIED
- 18 years of age or older on day of signing consent
- Any gender
- Functional pacemaker or ICD and using remote follow-up for their CEID
- Not scheduled for planned catheter ablation or cardioversion
- Ability to sign consent in English or Spanish
Exclusion Criteria:
- Permanent atrial fibrillation
- Pregnancy (in prospective arm only)
- Expected survival <1 year
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Other
Cohorts and Interventions
Group / Cohort |
Intervention / Treatment |
---|---|
Retrospective
Patients with available data for 6 months before the implantation of the Optimizer implantation and at least 8 months after the implantation of the optimizer at the time the study is initiated and patients with available data for 6 months before the implantation of the Optimizer implantation, but less than 8 months of follow up after Optimizer implantation at the time of the study initiation.
|
The Impulse Dynamics Optimizer is indicated for patients with New York Heart Association (NYHA) class III congestive heart failure (CHF) with left ventricular ejection fraction (LVEF) between 25 and 45% who are not candidates for cardiac resynchronization therapy.
The Optimizer device requires a minimally invasive implant by a cardiac electrophysiologist with two transvenous pacemaker wires implanted into the right ventricular septum and attached to a generator in an infraclavicular region, much like a pacemaker.
The Optimizer device provides CCM through improved calcium handling and has been shown to reverse the negative remodeling of the left ventricle seen in HFrEF and improve left ventricular contractile strength.
|
Prospective
Patients prior to the implantation of the Optimizer that will take place as per standard of care.
|
The Impulse Dynamics Optimizer is indicated for patients with New York Heart Association (NYHA) class III congestive heart failure (CHF) with left ventricular ejection fraction (LVEF) between 25 and 45% who are not candidates for cardiac resynchronization therapy.
The Optimizer device requires a minimally invasive implant by a cardiac electrophysiologist with two transvenous pacemaker wires implanted into the right ventricular septum and attached to a generator in an infraclavicular region, much like a pacemaker.
The Optimizer device provides CCM through improved calcium handling and has been shown to reverse the negative remodeling of the left ventricle seen in HFrEF and improve left ventricular contractile strength.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Change in Atrial fibrillation (AF) burden
Time Frame: 8 months post optimizer implantation
|
Compare the AF burden noted 6 months pre Optimizer implant to 6 post Optimizer months (post Optimizer months 3-8), after 2 month blanking period
|
8 months post optimizer implantation
|
Collaborators and Investigators
Sponsor
Collaborators
Investigators
- Principal Investigator: Sameer Jamal, MD, Hackensack Meridian Health
Publications and helpful links
General Publications
- Healey JS, Connolly SJ, Gold MR, Israel CW, Van Gelder IC, Capucci A, Lau CP, Fain E, Yang S, Bailleul C, Morillo CA, Carlson M, Themeles E, Kaufman ES, Hohnloser SH; ASSERT Investigators. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med. 2012 Jan 12;366(2):120-9. doi: 10.1056/NEJMoa1105575. Erratum In: N Engl J Med. 2016 Mar 10;374(10):998.
- Lardizabal JA, Deedwania PC. Atrial fibrillation in heart failure. Med Clin North Am. 2012 Sep;96(5):987-1000. doi: 10.1016/j.mcna.2012.07.007. Epub 2012 Aug 17.
- Verma A, Kalman JM, Callans DJ. Treatment of Patients With Atrial Fibrillation and Heart Failure With Reduced Ejection Fraction. Circulation. 2017 Apr 18;135(16):1547-1563. doi: 10.1161/CIRCULATIONAHA.116.026054.
- Mosterd A, Cost B, Hoes AW, de Bruijne MC, Deckers JW, Hofman A, Grobbee DE. The prognosis of heart failure in the general population: The Rotterdam Study. Eur Heart J. 2001 Aug;22(15):1318-27. doi: 10.1053/euhj.2000.2533.
- Saltzman HE. Arrhythmias and heart failure. Cardiol Clin. 2014 Feb;32(1):125-33, ix. doi: 10.1016/j.ccl.2013.09.005. Epub 2013 Oct 18.
- Kuschyk J, Falk P, Demming T, Marx O, Morley D, Rao I, Burkhoff D. Long-term clinical experience with cardiac contractility modulation therapy delivered by the Optimizer Smart system. Eur J Heart Fail. 2021 Jul;23(7):1160-1169. doi: 10.1002/ejhf.2202. Epub 2021 May 17.
- Piccini JP, Dufton C, Carroll IA, Healey JS, Abraham WT, Khaykin Y, Aleong R, Krueger SK, Sauer WH, Wilton SB, Rienstra M, van Veldhuisen DJ, Anand IS, White M, Camm AJ, Ziegler PD, Marshall D, Bristow MR, Connolly SJ; Genotype-Directed Comparative Effectiveness Trial of Bucindolol and Toprol-XL for Prevention of Atrial Fibrillation/Atrial Flutter in Patients with Heart Failure Trial Investigators*. Bucindolol Decreases Atrial Fibrillation Burden in Patients With Heart Failure and the ADRB1 Arg389Arg Genotype. Circ Arrhythm Electrophysiol. 2021 Aug;14(8):e009591. doi: 10.1161/CIRCEP.120.009591. Epub 2021 Jul 16.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Anticipated)
Study Completion (Anticipated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
- Pro2022-0954
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Atrial Fibrillation
-
Ablacon, Inc.CompletedArrhythmias, Cardiac | Atrial Fibrillation, Persistent | Persistent Atrial Fibrillation | Longstanding Persistent Atrial FibrillationGermany
-
Ablacon, Inc.RecruitingAtrial Fibrillation | Arrhythmias, Cardiac | Arrhythmia | Atrial Flutter | Atrial Fibrillation, Persistent | Atrial Tachycardia | Atrial Arrhythmia | Atrial Fibrillation Paroxysmal | Atrial Fibrillation, Paroxysmal or PersistentUnited States, Belgium, Netherlands, Czechia
-
Barts & The London NHS TrustAtriCure, Inc.Not yet recruitingAtrial Fibrillation, Persistent | Persistent Atrial Fibrillation | Atrial Arrhythmia | Atrium; FibrillationUnited Kingdom
-
AtriCure, Inc.Active, not recruitingPersistent Atrial Fibrillation | Atrial Fibrillation (AF) | Longstanding Persistent Atrial FibrillationUnited States
-
Maastricht University Medical CenterRWTH Aachen UniversityUnknownAtrial Fibrillation (Paroxysmal) | Atrial Fibrillation Recurrent | Atrial Fibrillation Common Gene VariantsNetherlands
-
Adagio MedicalRecruitingAtrial Fibrillation | Atrial Flutter | Paroxysmal Atrial Fibrillation | Persistent Atrial FibrillationNetherlands, Germany, Belgium
-
Vivek ReddyEnrolling by invitationAtrial Fibrillation and Flutter | Atrial Flutter Typical | Atrial Fibrillation, Paroxysmal or PersistentUnited States
-
Fundació Institut de Recerca de l'Hospital de la...RecruitingAtrial Arrhythmia | Atrial Fibrillation and Flutter | Atrial Fibrillation RecurrentSpain
-
Abbott Medical DevicesRecruitingAtrial Fibrillation | Paroxysmal Atrial Fibrillation | Persistent Atrial Fibrillation | Atrial ArrhythmiaUnited States, Australia, Belgium, Germany, Spain, Netherlands, France, Austria, Canada, Czechia, Italy, United Kingdom
-
St. George's Hospital, LondonRecruitingAtrial Fibrillation | Atrial Fibrillation, Persistent | Persistent Atrial Fibrillation | Atrial ArrhythmiaUnited Kingdom
Clinical Trials on Impulse Dynamics Optimizer Device
-
Luzerner KantonsspitalMedtronic - MITG; Orthofix Inc.Completed
-
National University of Ireland, Galway, IrelandIrish Research Council; Galway ClinicCompleted
-
National University of Ireland, Galway, IrelandIrish Research Council; Galway ClinicCompleted
-
Johns Hopkins UniversityTerminatedThrombophiliaUnited States