Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Thyroid Ultrasound Elasticity (TrUE) Imaging

1. Dezember 2019 aktualisiert von: Stanislav Emelianov, Emory University

Multi-Angle Compound Shear Wave Elasticity Imaging for the Characterization of Thyroid Nodules

In this study the researchers will scan the thyroid nodules of patients scheduled for surgical removal of these nodules. During their preadmission testing, but prior to their surgery, the researchers will perform standard ultrasound and shear wave elasticity imaging (SWEI) scans of the thyroid nodules in these patients. Both images can be generated by the same ultrasound scanner and within the same imaging session without having to switch out any equipment. The results of the SWEI scans will be compared to the definitive diagnosis from pathology obtained after pathologists have examined the removed nodules post-operatively.

Studienübersicht

Status

Abgeschlossen

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

Thyroid ultrasound is a first-line procedure to assess patients with thyroid nodules. Unfortunately, standard ultrasound has low sensitivity, and thus low positive predictive value, for malignancy and many patients with thyroid nodules are referred for additional imaging studies or biopsy. Shear wave elasticity imaging (SWEI) is a non-invasive ultrasound technology that allows clinicians to assess the stiffness of tissues. In many solid tumors, increased stiffness is highly specific for underlying malignancy, and preliminary studies have shown this to be true for thyroid malignancies. Both standard sonography and SWEI can be performed on the same ultrasound equipment and within the same imaging session. Therefore, integrating SWEI into standard thyroid diagnostic workflow is a logical approach towards improving the positive predictive value of these first-line sonographic studies. Other studies have demonstrated the ability of SWEI techniques to differentiate benign from malignant thyroid nodules. However, shear wave techniques still need to overcome challenges before they can be successfully integrated into the clinical paradigm. These techniques still struggle to accurately classify follicular carcinomas and few have been validated in patients with multiple thyroid lesions, a scenario which is clinically common. The researchers believe that a multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging. To this end, this study will perform proof-of-concept studies of MAC-SWEI in thyroid patients undergoing standard ultrasound scans and compare the results of shear wave images to results from corresponding pathology.

Study participants will undergo a single SWEI session within their normally-scheduled preadmission testing during which both standard b-mode and shear images of the thyroid nodule(s) will be acquired. The 36 patients will be randomized to receive MAC-SWEI, standard SWEI, and ultrasound, or only standard SWEI and ultrasound.

Studientyp

Beobachtungs

Einschreibung (Tatsächlich)

31

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Georgia
      • Atlanta, Georgia, Vereinigte Staaten, 30308
        • Emory Univeristy Hospital Midtown

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Probenahmeverfahren

Nicht-Wahrscheinlichkeitsprobe

Studienpopulation

Study participants will be recruited from patients of the Emory Healthcare system who are scheduled to have a thyroid biopsy, thyroidectomy, or cervical node biopsy.

Beschreibung

Inclusion Criteria:

  • Age ≥ 18 years old
  • Scheduled to undergo a thyroid biopsy, thyroidectomy, or cervical node biopsy

Exclusion Criteria:

  • None

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

Kohorten und Interventionen

Gruppe / Kohorte
Intervention / Behandlung
MAC-SWEI, standard SWEI, ultrasound
Participants in this group will receive all three imaging techniques
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system. During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session. The generation of shear wave images consists of two important steps called "pushing" and "tracking". First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing. In the "tracking" mode, shear wave propagation is observed and recorded. Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Andere Namen:
  • SWEI
The multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging. To assess the MAC-SWEI technique, shear wave images will be used to generate estimates of the relative stiffness of lesions via their normalized Young's modulus.
Andere Namen:
  • MAC-SWEI
Standard SWEI, ultrasound
Participants in this group will receive two imaging techniques
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system. During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session. The generation of shear wave images consists of two important steps called "pushing" and "tracking". First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing. In the "tracking" mode, shear wave propagation is observed and recorded. Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Andere Namen:
  • SWEI

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Determination of Malignancy by SWEI Imaging
Zeitfenster: Pre-operative visit (within 24 hours before surgery, on average)
As part of the pre-operative visit, participants will have imaging of their thyroid nodules. Established SWEI and MAC-SWEI techniques will be performed to identify malignant thyroid tissue.
Pre-operative visit (within 24 hours before surgery, on average)
Determination of Malignancy by Pathological Proof
Zeitfenster: Post-surgery (within 10 days after surgery, on average)
Tissue samples obtained during the participant's thyroid biopsy, thyroidectomy, or cervical node biopsy will be submitted to the pathology lab as part of the clinical standard of care. The pathology report will specify whether or not malignant cells were found in the tissue sample.
Post-surgery (within 10 days after surgery, on average)

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Accuracy of differentiating benign from malignant lesions between SWEI techniques
Zeitfenster: Pre-operative visit (within 24 hours before surgery, on average)
The ability of MAC-SWEI to differentiate benign from malignant lesions will be compared to the ability of standard SWEI to make this differentiation.
Pre-operative visit (within 24 hours before surgery, on average)

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Ermittler

  • Hauptermittler: Stanislav Emelianov, PhD, Emory University

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

23. Oktober 2017

Primärer Abschluss (Tatsächlich)

13. Juli 2018

Studienabschluss (Tatsächlich)

13. Juli 2018

Studienanmeldedaten

Zuerst eingereicht

3. Oktober 2017

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

6. Oktober 2017

Zuerst gepostet (Tatsächlich)

12. Oktober 2017

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

3. Dezember 2019

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

1. Dezember 2019

Zuletzt verifiziert

1. Dezember 2019

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • IRB00092785

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Ja

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Ja

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Ultrasound

Suchen Sie nach ähnlichen Studien