Thyroid Ultrasound Elasticity (TrUE) Imaging
Multi-Angle Compound Shear Wave Elasticity Imaging for the Characterization of Thyroid Nodules
Обзор исследования
Статус
Статус
Условия
Условия
Вмешательство/лечение
Вмешательство/лечение
Подробное описание
Thyroid ultrasound is a first-line procedure to assess patients with thyroid nodules. Unfortunately, standard ultrasound has low sensitivity, and thus low positive predictive value, for malignancy and many patients with thyroid nodules are referred for additional imaging studies or biopsy. Shear wave elasticity imaging (SWEI) is a non-invasive ultrasound technology that allows clinicians to assess the stiffness of tissues. In many solid tumors, increased stiffness is highly specific for underlying malignancy, and preliminary studies have shown this to be true for thyroid malignancies. Both standard sonography and SWEI can be performed on the same ultrasound equipment and within the same imaging session. Therefore, integrating SWEI into standard thyroid diagnostic workflow is a logical approach towards improving the positive predictive value of these first-line sonographic studies. Other studies have demonstrated the ability of SWEI techniques to differentiate benign from malignant thyroid nodules. However, shear wave techniques still need to overcome challenges before they can be successfully integrated into the clinical paradigm. These techniques still struggle to accurately classify follicular carcinomas and few have been validated in patients with multiple thyroid lesions, a scenario which is clinically common. The researchers believe that a multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging. To this end, this study will perform proof-of-concept studies of MAC-SWEI in thyroid patients undergoing standard ultrasound scans and compare the results of shear wave images to results from corresponding pathology.
Study participants will undergo a single SWEI session within their normally-scheduled preadmission testing during which both standard b-mode and shear images of the thyroid nodule(s) will be acquired. The 36 patients will be randomized to receive MAC-SWEI, standard SWEI, and ultrasound, or only standard SWEI and ultrasound.
Тип исследования
Тип исследования
Регистрация (Действительный)
Регистрация
Контакты и местонахождение
Места учебы
-
-
Georgia
-
Atlanta, Georgia, Соединенные Штаты, 30308
- Emory Univeristy Hospital Midtown
-
-
Критерии участия
Критерии приемлемости
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Метод выборки
Исследуемая популяция
Описание
Inclusion Criteria:
- Age ≥ 18 years old
- Scheduled to undergo a thyroid biopsy, thyroidectomy, or cervical node biopsy
Exclusion Criteria:
- None
Учебный план
Как устроено исследование?
Детали дизайна
Количество групп / когорт
Когорты и вмешательства
Группа / когортаГруппа / когорта |
Вмешательство/лечениеВмешательство/лечение |
|---|---|
|
MAC-SWEI, standard SWEI, ultrasound
Participants in this group will receive all three imaging techniques
|
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system.
During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session.
The generation of shear wave images consists of two important steps called "pushing" and "tracking".
First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing.
In the "tracking" mode, shear wave propagation is observed and recorded.
Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Другие имена:
The multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging.
To assess the MAC-SWEI technique, shear wave images will be used to generate estimates of the relative stiffness of lesions via their normalized Young's modulus.
Другие имена:
|
|
Standard SWEI, ultrasound
Participants in this group will receive two imaging techniques
|
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system.
During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session.
The generation of shear wave images consists of two important steps called "pushing" and "tracking".
First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing.
In the "tracking" mode, shear wave propagation is observed and recorded.
Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Другие имена:
|
Что измеряет исследование?
Первичные показатели результатов
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Determination of Malignancy by SWEI Imaging
Временное ограничение: Pre-operative visit (within 24 hours before surgery, on average)
|
As part of the pre-operative visit, participants will have imaging of their thyroid nodules.
Established SWEI and MAC-SWEI techniques will be performed to identify malignant thyroid tissue.
|
Pre-operative visit (within 24 hours before surgery, on average)
|
|
Determination of Malignancy by Pathological Proof
Временное ограничение: Post-surgery (within 10 days after surgery, on average)
|
Tissue samples obtained during the participant's thyroid biopsy, thyroidectomy, or cervical node biopsy will be submitted to the pathology lab as part of the clinical standard of care.
The pathology report will specify whether or not malignant cells were found in the tissue sample.
|
Post-surgery (within 10 days after surgery, on average)
|
Вторичные показатели результатов
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Accuracy of differentiating benign from malignant lesions between SWEI techniques
Временное ограничение: Pre-operative visit (within 24 hours before surgery, on average)
|
The ability of MAC-SWEI to differentiate benign from malignant lesions will be compared to the ability of standard SWEI to make this differentiation.
|
Pre-operative visit (within 24 hours before surgery, on average)
|
Соавторы и исследователи
Спонсор
Спонсор
Следователи
Следователи
- Главный следователь: Stanislav Emelianov, PhD, Emory University
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Начало исследования
Первичное завершение (Действительный)
Первичное завершение
Завершение исследования (Действительный)
Завершение исследования
Даты регистрации исследования
Первый отправленный
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Первый опубликованный
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее опубликованное обновление
Последнее отправленное обновление, отвечающее критериям контроля качества
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
Другие идентификационные номера исследования
- IRB00092785
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
продукт, произведенный в США и экспортированный из США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .
Клинические исследования Рак, щитовидная железа
-
NCT06808412Рекрутинг
-
NCT02847780ЗавершенныйОбъективная оценка движения голосовых связок с помощью видеоларингоскопа C-Mac в сравнении с ультразвуковым исследованием дыхательных путей в Ca Thyroid
-
NCT06855849Еще не набираютRAS/BRAF DILE-TYPE Advanced Corelectal Cancer Pement
Клинические исследования Ultrasound
-
NCT07042984Еще не набираютЛимфатические метастазы | Новообразования щитовидной железы | Папиллярная карцинома щитовидной железы | Рет-прото-инкогена мутация
-
NCT06892405Еще не набираютОсложнение дыхательных путей при анестезии
-
NCT05620290Рекрутинг
-
NCT07178080Запись по приглашениюУзел щитовидной железы | Узлы щитовидной железы
-
NCT04431648Рекрутинг
-
NCT06036550ЗавершенныйДопплеровское измерение маточной артерии
-
NCT07048691Активный, не рекрутирующий
-
NCT07431138ЗавершенныйАртропластика, Замена, Хип | Послеоперационная оценка
-
NCT06876805РекрутингОчаговое поражение печени