Screening of Cardiac Arrhythmias With Wrist-worn Aino ECG Cardiac Monitor
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Részletes leírás
The study consists of monitoring voluntary subjects with PulseOn Arrhythmia Monitoring System for the period of two weeks. The subjects are recruited mainly through newspaper advertisements. The study is executed in Tampere and Helsinki areas, Finland.
During the two week monitoring time, the subjects are instructed to wear the wrist device continuously, except when taking the device off e.g. for going to sauna or swimming, and for charging. The subjects are instructed to perform a 35-second ECG measurement (recording) in three cases:
- Scheduled recording four times a day
- In case of suspecting arrhythmic event, i.e. feeling symptoms
- In case the wrist device instructs to perform a recording by vibrating and showing an LED light
The data collected in the study is analysed post-hoc. In the post-hoc analysis, the cardiac rhythm assessed automatically from the ECG measurements is visually confirmed by a cardiologist.
Tanulmány típusa
Beiratkozás (Várható)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi kapcsolat
- Név: Antti Vehkaoja, DSc (tech)
- Telefonszám: +358407393181
- E-mail: antti.vehkaoja@pulseon.fi
Tanulmányi helyek
-
-
-
Tampere, Finnország
- Toborzás
- Tampere Heart Hospital
-
Kapcsolatba lépni:
- Research coordinator at Heart Hospital
- Telefonszám: +358417306125
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria for the main study group:
- At least 65 years of age
- Self-assessed ability to use the study devices
- Ability to give informed consent
- Volunteering for the study
Inclusion criteria for the active endurance athlete group:
- Minimum of 10 years of active training of endurance sport (e.g. long distance running, skiing, cycling, triathlon…) and currently an average amount of training of at least 10 hours a week.
- Age: ≥ 50 years
- Self-assessed ability to use the study devices
- Ability to give informed consent
- Volunteering for the study
Exclusion Criteria for both groups:
- Cardiac pacemaker
- Earlier diagnosis of atrial fibrillation
- Inability to give informed consent
- Denial
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Szűrés
- Kiosztás: Nem véletlenszerű
- Beavatkozó modell: Párhuzamos hozzárendelés
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
---|---|
Kísérleti: Main study group
Normal subjects of at least 65 years of age
|
Wearing of the wrist device for a period of two weeks
|
Kísérleti: Endurance athlete group
Group consists of active endurance athletes of at least 50 years of age
|
Wearing of the wrist device for a period of two weeks
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
---|---|---|
Diagnostic performance improvement with continuous optical measurement
Időkeret: Duration of patient measurement, i.e. two weeks
|
Percentual improvement in the performance of detecting previously undiagnosed atrial fibrillation in the study population by the continuous PPG-based heartbeat interval monitoring when compared with relying only on scheduled and symptom -based ECG measurements.
Cardiac rhythm assessed by a cardiologist from the ECG measurements that are made as a result of PPG-based arrhythmia notifications is compared with rhythm assessments made only from the scheduled and symptom-based ECG measurements.
It is evaluated whether more subjects can be diagnosed having atrial fibrillation with the help of continuous PPG-based rhythm monitoring.
|
Duration of patient measurement, i.e. two weeks
|
Validation of the clinical performance of PulseOn Arrhythmia Monitor System in general population by showing the adequacy of the obtained ECG data for clinical decision making.
Időkeret: Duration of patient measurement, i.e. two weeks
|
Data recorded by the study subjects during the two-week study time is assessed by a cardiologist and subjects are classified as having: "no observed arrhythmias", "atrial fibrillation episode(s)", "other potential arrhythmia", or "unconfident assessment" (due to the quality or lack of data).
The percentage of "unconfident assessment" shall be less than 20% of the subjects.
|
Duration of patient measurement, i.e. two weeks
|
Validation of the clinical performance of PulseOn Arrhythmia Monitor System in general population by showing sufficient patient convenience for using the device for the intended duration of two weeks
Időkeret: Duration of patient measurement, i.e. two weeks
|
The feedback from the subjects should show at least grade 3 in a scale of 1-5 for the "comfortability of using the wrist device".
|
Duration of patient measurement, i.e. two weeks
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
---|---|---|
Showing the benefit of the combined wrist-worn PPG and ECG solution in detecting other cardiac arrhythmias than atrial fibrillation.
Időkeret: Duration of patient measurement, i.e. two weeks
|
The visual ECG-based rhythm annotation made by a cardiologist is compared with simultaneous PPG-algorithm alarm state.
The incidence of notifications for other arrhythmias than atrial fibrilation is reported.
|
Duration of patient measurement, i.e. two weeks
|
Evaluation of the necessity of performing scheduled ECG measurements in addition to ECG measurements triggered by PPG-based arrhythmia notifications for detecting atrial fibrillation.
Időkeret: Duration of patient measurement, i.e. two weeks
|
Evaluation is done by comparing the atrial fibrillation detection outcome when considering only the PPG-triggered and symptom-based ECG measurements or when considering also the scheduled ECG measurements.
The outcome parameter is the number of subjects that would have been left undetected if the scheduled ECG measurements were not taken.
|
Duration of patient measurement, i.e. two weeks
|
Feedback about the usability of the evaluated solution from study subjects.
Időkeret: At the end of the 2-week measurement period
|
Feedback questions in scale of 1-5 and open-ended feedback.
Easiness of use of the wrist device, understandability of the user interface, suitability of the user materials, and unobtrusiveness.
|
At the end of the 2-week measurement period
|
Feedback about the usability of the evaluated solution from study personnel.
Időkeret: At the end of the study i.e. the end of 2022.
|
Feedback questions in scale of 1-5 and open-ended feedback.
Easiness of use of the data management service, suitability of the user materials.
|
At the end of the study i.e. the end of 2022.
|
Quality of the measured ECG signals
Időkeret: Duration of patient measurement, i.e. two weeks
|
Percentage of the ECG measurements classified as inadequate quality for rhythm assessment either an ECG analysis algorithm or by a doctor.
|
Duration of patient measurement, i.e. two weeks
|
Assessment of the subjects' adherence in using the solution.
Időkeret: Duration of patient measurement, i.e. two weeks
|
Analysis of how well the participants will follow the study protocol and do the participants register their ECG in correlation with the wrist device notification.
The outcome parameter is the percentage of scheduled and PPG-based notifications to take an ECG measurement and the variation of the percentage between the subjects.
|
Duration of patient measurement, i.e. two weeks
|
Benefit of optical measurement for the speed of detecting atrial fibrillation
Időkeret: Duration of patient measurement, i.e. two weeks
|
Comparison of the time to the first detection of atrial fibrillation or other arrhythmia when considering PPG-triggered ECG measurements or when considering the scheduled ECG measurements.
|
Duration of patient measurement, i.e. two weeks
|
Evaluation of the accuracy of automatic ECG analysis algorithms when comparing with manual annotations by a cardiologist.
Időkeret: Duration of patient measurement, i.e. two weeks
|
The automated assessment done for the 30-second ECG recordings is compared with the visual assessment to calculate the sensitivity and specificity for each rhythm category.
|
Duration of patient measurement, i.e. two weeks
|
Együttműködők és nyomozók
Szponzor
Nyomozók
- Kutatásvezető: Vesa Virtanen, PhD (med), Heart Hospital of Tampere University Hospital
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
Elsődleges befejezés (Várható)
A tanulmány befejezése (Várható)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- AinoScreening
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .
Klinikai vizsgálatok a Pitvarfibrilláció
-
Assiut UniversityVisszavontASD2 (Secundum Atrial Septal Defect)