このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

The Application of a Wireless Sensor Technology for Vital Statistics in CHILDREN AND ADULTS

2020年9月1日 更新者:Naveen Poonai、Lawson Health Research Institute
The primary outcome for this project will be the development of a small, non-invasive wireless sensor that is linked to a conventional computer that can be used in health care for monitoring of acute and chronic health problems. The advantages of developing this technology are threefold. First, monitoring can be conducted for a fraction of the cost of a bedside nurse. Second, monitoring can be done in real time and stored so that we can diagnose and manage critical events in a more timely manner. Lastly, many patients can be monitored simultaneously. The wireless sensors will be fitted to healthy volunteers of various ages. The data gathered from the sensor with respect to their vital signs will be compared to that of conventional tools such as nursing assessments and pulse oximetry.

調査の概要

研究の種類

介入

入学 (予想される)

500

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

  • 名前:Naveen Poonai, MD
  • 電話番号:52011 5196858500
  • メールpoonai@hotmail.com

研究場所

    • Ontario
      • London、Ontario、カナダ、N6A2V5
        • Children's Hospital London Health Sciences Center
        • コンタクト:

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Adults with controlled and non-controlled hypertension (hypertension defined as > 130/90 on two separate occasions and history of hypertension)
  • Adults with known chronic obstructive pulmonary disease in respiratory distress with oxygen saturations < 90%
  • Febrile adults (temp at triage > 38 C) with no significant co-morbidities
  • Elderly (>70 years) patients with no significant co-morbidities
  • Obese adults (BMI > 30)
  • Febrile (temp at triage > 38 C) and non-febrile children (age < 18 yrs)
  • Obese children (BMI > 30)
  • Neonates (age < 6 weeks)
  • Children with corrected cyanotic congenital heart disease
  • Children in respiratory distress that present with oxygen saturations < 90%

Exclusion Criteria:

-Subjects with unstable vital signs will be excluded.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:診断
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Wireless pressure transducer
Following informed consent, each subject will be fitted with a wireless sensor attached to a conventional laptop computer. The sensors fit around the participant's chest and work as transducers.
Following informed consent, each subject will be fitted with a wireless sensor attached to a conventional laptop computer. The sensors fit around the participant's chest and work as transducers.
アクティブコンパレータ:Cardiorespiratory Monitor
Following informed consent, each subject will be also be fitted with ECG leads (five), and an oxygen saturation monitor. This information as well as blood pressure and temperature will be recorded at 5-minute intervals by a nurse.
Subjects will also be fitted with conventional monitoring devices as per the standard of care (3 or 5 lead ECG, pulse oximeter, blood pressure cuff) and will have vital statistics obtained by a trained research assistant at regular 5-minute intervals including blood pressure, heart rate, temperature, and respiratory rate using the standard cardiorespiratory bedside monitor's cycling protocol. The same parameters will be obtained from the wireless sensor at identical time points for a duration of 2 hours. Data obtained from both conventional and study sources will be entered into an encrypted USB device for later analysis.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
The primary outcome is the level of agreement between cardiorespiratory monitor and sensor information for heart rate.
時間枠:2 hours
The primary outcome is the level of agreement between conventional methods and sensor information for heart rate.
2 hours
Level of agreement between cardiorespiratory monitor and sensor information for blood pressure
時間枠:2 hours
The primary outcome is the level of agreement between conventional methods and sensor information for blood pressure.
2 hours
Level of agreement between cardiorespiratory monitor and sensor information for temperature
時間枠:2 hours
The primary outcome is the level of agreement between conventional methods and sensor information for temperature.
2 hours
Level of agreement between cardiorespiratory monitor and sensor information for oxygen saturation
時間枠:2 hours
The primary outcome is the level of agreement between conventional methods and sensor information for oxygen saturation.
2 hours

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (予想される)

2021年12月1日

一次修了 (予想される)

2023年9月1日

研究の完了 (予想される)

2023年12月1日

試験登録日

最初に提出

2013年4月25日

QC基準を満たした最初の提出物

2013年5月1日

最初の投稿 (見積もり)

2013年5月3日

学習記録の更新

投稿された最後の更新 (実際)

2020年9月3日

QC基準を満たした最後の更新が送信されました

2020年9月1日

最終確認日

2020年9月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • 2166

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

Wireless pressure sensorの臨床試験

3
購読する