- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT01169493
Pacing Affects Cardiovascular Endpoints in Patients With Right Bundle-Branch Block (The PACE-RBBB Trial) (PACE-RBBB)
1 sierpnia 2016 zaktualizowane przez: Duke University
Heart failure (HF) affects 5 million Americans and is responsible for more health-care expenditure than any other medical diagnosis.
Approximately half of all HF patients have electrocardiographic prolongation of the QRS interval and ventricular dyssynchrony, a perturbation of the normal pattern of ventricular contraction that reduces the efficiency of ventricular work.
Ventricular dyssynchrony is directly responsible for worsening HF symptomatology in this subset of patients.
Resynchronization of ventricular contraction is usually achieved through simultaneous pacing of the left and right ventricles using a biventricular (BiV) pacemaker or implantable cardioverter-defibrillator.
Clinical trial evidence supporting the use of BiV pacing in patients with prolonged QRS duration was obtained almost exclusively in patients with a left bundle-branch block (LBBB) electrocardiographic pattern.
Recent evidence suggests that resynchronization of ventricular contraction in patients with LBBB can be obtained by univentricular left ventricular pacing with equal or superior clinical benefits compared to BiV pacing.
Animal studies suggest that ventricular resynchronization can be obtained in subjects with right bundle-branch block (RBBB) through univentricular right ventricular pacing.
No clinical trial evidence exists to support the use of BiV pacing in patients with RBBB.
Thousands of patients with symptomatic HF and RBBB currently have univentricular ICDs in place for the prevention of sudden cardiac death.
Most of these devices are currently programmed to avoid RV pacing.
We aim to determine if ventricular resynchronization delivered through univentricular RV pacing improves symptoms in patients with RBBB and moderate to severe HF who have previously undergone BiV ICD implantation for symptomatic heart failure.
We further aim to determine if ventricular resynchronization improves myocardial performance and ventricular geometry as detected by echocardiographic measures and quality of life for patients with HF and RBBB.
We hypothesize that RV univentricular pacing delivered with an atrio-ventricular interval that maximizes ventricular synchrony is equivalent to BiV pacing for improvement in cardiac performance, HF symptoms, and positive ventricular remodeling in patients with HF and RBBB.
Przegląd badań
Status
Zakończony
Interwencja / Leczenie
Typ studiów
Interwencyjne
Zapisy (Rzeczywisty)
16
Faza
- Nie dotyczy
Kontakty i lokalizacje
Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.
Lokalizacje studiów
-
-
North Carolina
-
Durham, North Carolina, Stany Zjednoczone, 27710
- Duke University Medical Center
-
Durham, North Carolina, Stany Zjednoczone, 27710
- Durham VA Medical Center
-
-
Kryteria uczestnictwa
Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.
Kryteria kwalifikacji
Wiek uprawniający do nauki
18 lat i starsze (Dorosły, Starszy dorosły)
Akceptuje zdrowych ochotników
Nie
Płeć kwalifikująca się do nauki
Wszystko
Opis
Inclusion Criteria:
- Cardiomyopathy of either idiopathic or ischemic etiology
- NYHA class III, or IV symptoms
- Sinus rhythm
- QRS complex duration > 130 msec in ≥ 2 surface ECG leads with RBBB
- PR interval > 150 msec and < 240 msec
- Prior implantation of dual chamber BiV ICD with apical RV lead location
Exclusion Criteria:
- Myocardial infarction, major surgical procedure, or acute cardiac failure crisis requiring inotropes within 6 months of entry into the study
- Atrial fibrillation or flutter lasting >12 hours within the last 6 months
- Sick sinus syndrome, complete heart block, or other arrhythmias requiring pacemaker support
- Pregnancy
- Any other known condition other than heart failure that could limit exercise time or survival to < 6 months
Plan studiów
Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Zadanie krzyżowe
- Maskowanie: Potroić
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
---|---|
Eksperymentalny: VVI-40 to RV DDD-40 to Bi-V DDD-40
Period 1: Participants assigned to VVI-40 Participants will then Crossover to Period 2. Period 2: Participants assigned to RV DDD-40 Participants will then Crossover to Period 3. Period 3: Participants assigned to Bi-V DDD-40
|
Pacing mode set to VVI-40, RV only pacing
ICD programmed to DDD-40, RV only pacing with aan AV interval producing QRS fusion on surface EKG.
ICD programmed to BiV pacing at a lower rate of 40
|
Eksperymentalny: VVI-40 to Bi-V DDD-40 to RV DDD-40
Period 1: Participants assigned to VVI-40 Participants will then Crossover to Period 2. Period 2: Participants assigned to Bi-V DDD-40 Participants will then Crossover to Period 3. Period 3: Participants assigned to RV DDD-40
|
Pacing mode set to VVI-40, RV only pacing
ICD programmed to DDD-40, RV only pacing with aan AV interval producing QRS fusion on surface EKG.
ICD programmed to BiV pacing at a lower rate of 40
|
Eksperymentalny: Bi-V DDD-40 to VVI-40 to RV DDD-40
Period 1: Participants assigned to Bi-V DDD-40 Participants will then Crossover to Period 2. Period 2: Participants assigned to VVI-40 Participants will then Crossover to Period 3. Period 3: Participants assigned to RV DDD-40
|
Pacing mode set to VVI-40, RV only pacing
ICD programmed to DDD-40, RV only pacing with aan AV interval producing QRS fusion on surface EKG.
ICD programmed to BiV pacing at a lower rate of 40
|
Eksperymentalny: Bi-V DDD-40 to RV DDD-40 to VVI-40
Period 1: Participants assigned to Bi-V DDD-40 Participants will then Crossover to Period 2. Period 2: Participants assigned to RV DDD-40 Participants will then Crossover to Period 3. Period 3: Participants assigned to VVI-40
|
Pacing mode set to VVI-40, RV only pacing
ICD programmed to DDD-40, RV only pacing with aan AV interval producing QRS fusion on surface EKG.
ICD programmed to BiV pacing at a lower rate of 40
|
Eksperymentalny: RV DDD-40 to VVI-40 to Bi-V DDD-40
Period 1: Participants assigned to RV DDD-40 Participants will then Crossover to Period 2. Period 2: Participants assigned to VVI-40 Participants will then Crossover to Period 3. Period 3: Participants assigned to Bi-V DDD-40
|
Pacing mode set to VVI-40, RV only pacing
ICD programmed to DDD-40, RV only pacing with aan AV interval producing QRS fusion on surface EKG.
ICD programmed to BiV pacing at a lower rate of 40
|
Eksperymentalny: RV DDD-40 to Bi-V DDD-40 to VVI-40
Period 1: Participants assigned to RV DDD-40 Participants will then Crossover to Period 2. Period 2: Participants assigned to Bi-V DDD-40 Participants will then Crossover to Period 3. Period 3: Participants assigned to VVI-40
|
Pacing mode set to VVI-40, RV only pacing
ICD programmed to DDD-40, RV only pacing with aan AV interval producing QRS fusion on surface EKG.
ICD programmed to BiV pacing at a lower rate of 40
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Ramy czasowe |
---|---|
The Primary Endpoint of the Trial Will be a Comparison of the Proportion of Patients in Each of the Three Treatment Groups Who Demonstrate Positive LV Remodeling, Defined as a Decrease in LV End Systolic Diameter of >5mm.
Ramy czasowe: 6 months
|
6 months
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
---|---|---|
Frakcja wyrzutowa lewej komory (LVEF)
Ramy czasowe: 6 miesięcy
|
6 miesięcy
|
|
Secondary Echocardiographic Endpoints
Ramy czasowe: 6 months
|
Comparisons of the derived velocity-time integral calculated on the aortic continuous wave Doppler-spectrogram, RV end-diastolic size, RV EF, mitral and tricuspid regurgitation severity, and estimated RV systolic pressure.
|
6 months
|
Arrhythmic Events
Ramy czasowe: 6 months
|
To determine if pacing mode impacts the frequency of ventricular arrhythmias, the incidence of ventricular tachyarrhythmia episodes on device interrogation will be compared between treatment group assignments.
An episode will be considered ventricular arrhythmia if it lasts longer than 30 seconds or requires anti-tachycardia pacing or high voltage device therapy for termination.
|
6 months
|
Minnesota Quality of Life Questionnaire
Ramy czasowe: 6 months
|
This is a standardized method for assessing quality of life in patients with heart failure.
It asks 21 questions and measures the impact HF has on a subject's life.
Each question is rated 0-5.
The total score for the 21 items can range from 0 to 105.
Higher scores indicate more burden of disease on quality of life.
|
6 months
|
6-minute Walk Distance
Ramy czasowe: 6 months
|
6-minute walk distance was the distance that a participant could walk in 6 minutes.
|
6 months
|
NYHA Function Class
Ramy czasowe: 6 months
|
The New York Heart Association (NYHA) Functional Classification places patients in one of four categories based on how much they are limited during physical activity.
Class I means there is no limitation of physical activity and Class IV means a person is unable to carry on any physical activity without discomfort/symptoms of heart failure at rest.
|
6 months
|
Left Ventricular End-diastolic Size
Ramy czasowe: 6 months
|
6 months
|
Współpracownicy i badacze
Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.
Sponsor
Współpracownicy
Śledczy
- Główny śledczy: Brett D Atwater, MD, Duke University
Daty zapisu na studia
Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.
Główne daty studiów
Rozpoczęcie studiów
1 stycznia 2011
Zakończenie podstawowe (Rzeczywisty)
1 sierpnia 2014
Ukończenie studiów (Rzeczywisty)
1 sierpnia 2014
Daty rejestracji na studia
Pierwszy przesłany
22 lipca 2010
Pierwszy przesłany, który spełnia kryteria kontroli jakości
22 lipca 2010
Pierwszy wysłany (Oszacować)
26 lipca 2010
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
23 września 2016
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
1 sierpnia 2016
Ostatnia weryfikacja
1 sierpnia 2016
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- Pro00025144
- 10CRP3630033 (Inny numer grantu/finansowania: American Heart Association)
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Niewydolność serca
-
Region SkaneRejestracja na zaproszenieNiewydolność serca Klasa II według New York Heart Association (NYHA). | Niewydolność serca Klasa III według New York Heart Association (NYHA).Szwecja
-
Medical University of BialystokInstitute of Cardiology, Warsaw, Poland; Medical University of Lodz; Poznan University... i inni współpracownicyJeszcze nie rekrutacjaNiewydolność serca, skurcz | Niewydolność serca ze zmniejszoną frakcją wyrzutową | Niewydolność serca Klasa IV według New York Heart Association | Niewydolność serca Klasa III według New York Heart AssociationPolska
-
University of WashingtonAmerican Heart AssociationZakończonyNiewydolność serca, zastoinowa | Zmiana mitochondrialna | Niewydolność serca Klasa IV według New York Heart AssociationStany Zjednoczone
Badania kliniczne na VVI-40
-
Federico II UniversityNieznanyNiewydolność serca | Tolerancja ćwiczeńWłochy
-
Azienda Ospedaliera Cardinale G. PanicoZakończonyMigotanie przedsionków | Dysfunkcja lewej komoryWłochy
-
Unity Health TorontoApplied Health Research Centre; Biotronik Canada IncAktywny, nie rekrutującyChoroby układu krążenia | Wszczepialne kardiowertery-defibrylatory | Zaburzenia rytmu serca | Migotanie i trzepotanie przedsionkówKanada
-
Federal State Budgetary Institution, V. A. Almazov...ZakończonyNiewydolność sercaFederacja Rosyjska
-
Azienda Ospedaliero Universitaria Maggiore della...ZakończonyNiewydolność serca ze zmniejszoną frakcją wyrzutową | Blok prawej odnogi pęczka Hisa | Stymulacja dwuogniskowaWłochy
-
University Medical Centre LjubljanaZakończonyBlok przedsionkowo-komorowy | Dyssynchronia przedsionkowo-komorowaSłowenia
-
Aarhus University Hospital SkejbyAarhus University Hospital; Biotronik SE & Co. KGZakończonyOmdlenie wazowagalneDania
-
Region Örebro CountyRekrutacyjnyMechaniczna wentylacja | Niedodma | Dystrybucja wentylacjiSzwecja
-
Yonsei UniversityNieznanyChoroba zwyrodnieniowa stawu kolanowegoRepublika Korei
-
Breas Medical S.A.R.L.WycofaneZespół hipowentylacji otyłościFrancja