- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT05574218
Effect of a Maintenance Protocol After Surgical Treatment of Peri-implantitis
Effect of a Maintenance Protocol Based on the Surgical Treatment of Peri-implantitis and Implant Surface Decontamination With Glycine Powder Air-polishing
Studieöversikt
Status
Betingelser
Intervention / Behandling
Detaljerad beskrivning
Study design:
This study was designed as a 12-month, two arms, RCT to evaluate the efficacy of a SPIC protocol. Thirty patients were randomized, six months after access-flap surgery, in two different SPIT groups. After ultrasonic debridement, the affected implant surfaces of the test group were treated with glycine powder air-polishing, while implants in the control group a rubber cup and polishing paste was used. Maintenance visits were carried every 3 months and clinical, radiological, microbiological and biochemical variables were registered at baseline (6 months after surgery) and after a follow-up period of 12 months (18 months after surgery).
Interventions:
At the 6-month evaluation after the surgery, the baseline data for the present study were obtained and patients were randomised using a computerized block randomization protocol to one of the following SPIC protocols. In the test group, implant surfaces were treated with glycine powder air-polishing after ultrasonic instrumentation; the specific nozzle was activated subgingivally and circumferentially around the implant for 1 minute. In the control group, implants were cleaned with a rubber cup and polishing paste after ultrasonic instrumentation. This SPIC visits were carried out at 6 (baseline visit), 9, 12, 15 and 18 months after surgery.
Studietyp
Inskrivning (Faktisk)
Fas
- Inte tillämpbar
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
- Barn
- Vuxen
- Äldre vuxen
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
- Presence of at least one implant with peri-implantitis, defined as: radiographic evidence of bone loss >2 mm, inflammation of the peri-implant mucosa as defined by positive BoP and/or suppuration, and at least one site with PD ≥ 5 mm.
- Based on the radiographic examination, the affected implant should not have a vertical peri-implant defect. Positive selection was based on the presence of pe-ri-implant lesions wider than 4 mm, with an angle greater than 35 º.
- In patients with a history of periodontitis, periodontal therapy should have been provided at least 6 months prior to the initiation of the study.
Exclusion Criteria:
- Presence of relevant medical conditions and/or systemic medications that would contraindicate the surgical procedure or modify the tissue response after therapy.
- Patients requiring antibiotic prophylaxis.
- Heavy smokers (> 10 cigarettes/day).
- Pregnant or lactating women
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Behandling
- Tilldelning: Randomiserad
- Interventionsmodell: Parallellt uppdrag
- Maskning: Enda
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
---|---|
Experimentell: Glycine - Test
Polishing treatment with glycine powder air-polishing after ultrasonic plaque debridement.
|
Every 3 months, ultrasonic instrumentation was carried out with an specific implant tip coated with Polyether Ether Ketone (PEEK), activated subgingivally and circumferentially around the implant.
Then, the implants were treated with glycine powder air-polishing.
|
Aktiv komparator: Rubber cup - Control
Polishing treatment with a rubber cup and polishing paste after ultrasonic debridement
|
Every 3 months, ultrasonic instrumentation was carried out with an specific implant tip coated with Polyether Ether Ketone (PEEK), activated subgingivally and circumferentially around the implant.
Then, the implants were treated with rubber cup and a polishing paste.
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
---|---|---|
Probing Pocket Depth
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Changes in Probing Pocket Depth measured in milimeters with a manual periodontal probe
|
Baseline, 6 and 18 months after the surgical procedure
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
---|---|---|
Distance of Gingival Recession
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Recession distance of the mucosal margin relative to the restoration margin (REC) at the implant (6 sites/implant) measured in milimeters with a manual periodontal probe
|
Baseline, 6 and 18 months after the surgical procedure
|
Bleeding on Probing index
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Rate of Presence / absence Bleeding on Probing at the implant (6 sites/implant)
|
Baseline, 6 and 18 months after the surgical procedure
|
Plaque Index
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Rate of Presence / absence of Plaque at the implant (6 sites/implant)
|
Baseline, 6 and 18 months after the surgical procedure
|
Suppuration Index
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Rate of Presence / absence of suppuration at the implant (6 sites/implant)
|
Baseline, 6 and 18 months after the surgical procedure
|
Radiographic bone loss distance measured from the prosthetic connection platform to the bottom of the intraosseous defect
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Intraoral standardised radiographs of the site of interest measured in digital intraoral radiographs using an image-processing software
|
Baseline, 6 and 18 months after the surgical procedure
|
Concentration of the selected cytokines measured in pg/ml (IL1B; Il-6; IL-8; Tumoral Necrosis Factor Alpha)
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Samples taken from the gingival crevicular fluid (GCF) were taken from each included implant from the deepest PD site with positive BoP, at baseline and at the final evaluation, always prior to microbiological sampling.
Samples were taken using the filter paper technique.
After isolation of the area with cotton rolls and gentle cleaning with air and a gauze to remove supragingival biofilm deposits and potential saliva contamination, a paper strip of standard length and height was inserted into the peri-implant pocket, until mild resistance was felt and left in place for 30 seconds.
The soaked volume of GCF was measured using the Periotron 8000® device.
Subsequently, the paper strips were inserted in micro-centrifuge plastic tubes and immediately stored at -80°C until further processing.
Analyses were carried out using a Luminex System (Luminex® 200, Luminex Corporation, Austin, TX, USA) to determine volume of the following biomarkers: IL-1β, IL-6, IL-8 and TNF-α.
|
Baseline, 6 and 18 months after the surgical procedure
|
Presence of putative periodontal pathogens
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Sample from the deepest site in the evaluated implant using two consecutive sterile paper-points kept in place for 10 seconds and then transferred into a screw-capped vial, containing 1.5 mL of reduced transport fluid (RTF).
Samples were transferred to the microbiological laboratory within 2 hours and homogenized by vortexing for 30 seconds and serially diluted in phosphate buffer saline (PBS).
Then, 0.1 mL of each dilution was plated manually on the specific medium Dentaid-1, for the detection of Aggregatibacter actinomycetemcomitans, and incubated for 3 days in air with 5% CO2 at 37ºC.
Samples were also plated into a non-selective blood agar plate, supplemented with haemine (5 mg/l), menadione (1 mg/l) and 5% sterile horse blood, with 7-14 days of anaerobic incubation.
|
Baseline, 6 and 18 months after the surgical procedure
|
Frequency of detection of putative periodontal pathogens
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Sample from the deepest site in the evaluated implant using two consecutive sterile paper-points kept in place for 10 seconds and then transferred into a screw-capped vial, containing 1.5 mL of reduced transport fluid (RTF).
Samples were transferred to the microbiological laboratory within 2 hours and homogenized by vortexing for 30 seconds and serially diluted in phosphate buffer saline (PBS).
Then, 0.1 mL of each dilution was plated manually on the specific medium Dentaid-1, for the detection of Aggregatibacter actinomycetemcomitans, and incubated for 3 days in air with 5% CO2 at 37ºC.
Samples were also plated into a non-selective blood agar plate, supplemented with haemine (5 mg/l), menadione (1 mg/l) and 5% sterile horse blood, with 7-14 days of anaerobic incubation.
|
Baseline, 6 and 18 months after the surgical procedure
|
Proportions of putative periodontal pathogens
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Sample from the deepest site in the evaluated implant using two consecutive sterile paper-points kept in place for 10 seconds and then transferred into a screw-capped vial, containing 1.5 mL of reduced transport fluid (RTF).
Samples were transferred to the microbiological laboratory within 2 hours and homogenized by vortexing for 30 seconds and serially diluted in phosphate buffer saline (PBS).
Then, 0.1 mL of each dilution was plated manually on the specific medium Dentaid-1, for the detection of Aggregatibacter actinomycetemcomitans, and incubated for 3 days in air with 5% CO2 at 37ºC.
Samples were also plated into a non-selective blood agar plate, supplemented with haemine (5 mg/l), menadione (1 mg/l) and 5% sterile horse blood, with 7-14 days of anaerobic incubation.
|
Baseline, 6 and 18 months after the surgical procedure
|
Counts of putative periodontal pathogens
Tidsram: Baseline, 6 and 18 months after the surgical procedure
|
Sample from the deepest site in the evaluated implant using two consecutive sterile paper-points kept in place for 10 seconds and then transferred into a screw-capped vial, containing 1.5 mL of reduced transport fluid (RTF).
Samples were transferred to the microbiological laboratory within 2 hours and homogenized by vortexing for 30 seconds and serially diluted in phosphate buffer saline (PBS).
Then, 0.1 mL of each dilution was plated manually on the specific medium Dentaid-1, for the detection of Aggregatibacter actinomycetemcomitans, and incubated for 3 days in air with 5% CO2 at 37ºC.
Samples were also plated into a non-selective blood agar plate, supplemented with haemine (5 mg/l), menadione (1 mg/l) and 5% sterile horse blood, with 7-14 days of anaerobic incubation.
|
Baseline, 6 and 18 months after the surgical procedure
|
Samarbetspartners och utredare
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- EMS/MTO
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .
Kliniska prövningar på Peri-implantit
-
Cynosure, Inc.AvslutadPeri-orala rynkor | Peri-orbitala rynkorFörenta staterna
-
Ulthera, IncAvslutadPeri-orala rynkor | Peri-orbitala rynkorFörenta staterna
-
University of ZagrebHar inte rekryterat ännuPeri-implantat mukosit | Peri-implantit och peri-implantat mukosit | Peri-implantat hälsa | Periimplantat sjukdomar | Periimplantat benförlust
-
Tuğba ŞAHİNAvslutadPeri-implantit, peri-implantat mukositKalkon
-
Proed, Torino, ItalyAvslutad
-
PolyPid Ltd.MIS Implant Technologies, LtdAvslutad
-
University of ManitobaOkändPeri implantitKanada
-
Universitaire Ziekenhuizen KU LeuvenDentsply Sirona Implants and ConsumablesAvslutad
-
Ramón Pons CalabuigRekryteringPeri-implantit | Peri-implantat mukosit | Peri-implantat hälsaSpanien
-
Hams Hamed AbdelrahmanAvslutad
Kliniska prövningar på Glycine air powder
-
University of Roma La SapienzaAvslutad
-
Massachusetts General HospitalAvslutadPerinatal asfyxi | Asphyxia Neonatorum | Asfyxi vid födseln
-
CIBA VISIONAvslutadPresbyopi | Astigmatism | Myopi
-
ResMedAvslutadSömnapné, obstruktivFörenta staterna
-
Right-AirUniversity of PennsylvaniaOkändKronisk obstruktiv lungsjukdom | KOLFörenta staterna
-
air up GmbHCitruslabsRekrytering
-
ResMedAvslutad
-
Massachusetts General HospitalMbarara University of Science and TechnologyAnmälan via inbjudanLunginflammation | Förorening; Exponering | Pediatriska luftvägssjukdomar | Lungfunktion minskad | Kronisk luftvägssjukdom | Lungor; UtvecklingsstörningUganda
-
University of Medicine and Dentistry of New JerseyAvslutadHuvudvärkFörenta staterna
-
National Health and Medical Research Council, AustraliaDoris Duke Charitable Foundation; Cancer Council Tasmania; Duke Institute... och andra samarbetspartnersAvslutad