GRX With ReMOTE: First in Human in India
CorPath GRX With ReMOTE Proof of Principle (POP): First in Human in India
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Gujarat
-
Ahmedabad, Gujarat, India, 380054
- Apex Heart Institute
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Age ≥18 years;
- Patients with coronary artery disease with clinical indication for PCI;
- Patient deemed appropriate for robotic-assisted PCI; and
- The subject has been informed of the nature of the study, agrees to its provisions and has provided written informed consent.
Angiographic Inclusion:
- Study lesion is a single de novo native coronary artery lesion (i.e. a coronary lesion not previously treated).
- The lesion reference vessel diameter is between 2.50 mm and 4.0 mm by visual estimate.
- Study lesion length less or equal to 20 mm by visual estimate.
- The study lesion length can be treated with one stent. The stent should be able to cover the whole length of the lesion with at least 2 mm of normal segments on proximal and distal edges of the lesion.
- Study lesion diameter showing significant stenosis of at least 50% by visual estimate.
Exclusion Criteria:
- Failure/inability/unwillingness to provide informed consent; or
- The investigator determines that the patient or the coronary anatomy is not suitable for robotic-assisted PCI.
Angiographic Exclusion:
- Target lesion that cannot be fully covered by a single stent.
- Subject requires treatment of multiple lesions
- Any previous stent placement within 5 mm (proximal or distal) of the target lesion
- The study lesion requires planned treatment with DCA, laser, rotational atherectomy, or any device except for balloon dilatation prior to stent placement
- The study vessel has evidence of intraluminal thrombus or moderate to severe tortuosity (> 90°) proximal to the target lesion
The study lesion has any of the following characteristics:
- Total occlusion
- Within 2mm of a side branch > 2.0 mm vessel diameter
- Not ostial in location
- Is located at ≥ 45° bend in the vessel
- Is severely tortuous
- Is severely calcified
- Severe calcification at the part of the vessel proximal to target lesion
- Target lesion that is located in a native vessel distal to an anastomosis with a saphenous vein graft or a left/right internal mammary artery (LIMA/RIMA) bypass and is approached through the by-pass graft
- Unprotected left main coronary artery disease (an obstruction greater than 50% diameter stenosis in the left main coronary artery)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Interventional Model: Sequential Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: Remote treatment of PCI.
5 sequential subjects presenting for remote PCI who have signed informed consent.
|
To evaluate the safety and performance of CorPath GRX POP System, in the ReMOTE (location outside hospital) delivery and manipulation of coronary guidewires and stent/balloon catheters, and manipulation of guide catheters during PCI procedures.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Device Technical Success
Time Frame: Measured from guide catheter in time through procedure end time (or guide catheter out time).
|
Defined as completing the robotic PCI entirely with the CorPath GRX POP System.
|
Measured from guide catheter in time through procedure end time (or guide catheter out time).
|
|
In-hospital MACE
Time Frame: Measured from Sheath in time to discharge or 48 hours, whichever occurs first.
|
Recording any MACE event that occurred from the time the sheath was inserted through 48 hours post procedure or hospital discharge, whichever of the two occurred first.
|
Measured from Sheath in time to discharge or 48 hours, whichever occurs first.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Clinical Procedural Success
Time Frame: Measured from guide catheter in time through procedure end time (or guide catheter out time).
|
Number of patients with a residual stenosis (visual estimate, less than 30%) post PCI in the lesion(s) treated with the CorPath GRX POP System.
|
Measured from guide catheter in time through procedure end time (or guide catheter out time).
|
|
All Serious Adverse Events
Time Frame: Measured from Sheath in time to discharge or 48 hours, whichever occurs first.
|
Recording any SAE that occurred measured from the sheath insertion time through 48 hours post procedure or hospital discharge, whichever occurred first.
|
Measured from Sheath in time to discharge or 48 hours, whichever occurs first.
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Tejas Patel, MD, Apex Heart Institute
Publications and helpful links
General Publications
- Madder RD, VanOosterhout SM, Jacoby ME, Collins JS, Borgman AS, Mulder AN, Elmore MA, Campbell JL, McNamara RF, Wohns DH. Percutaneous coronary intervention using a combination of robotics and telecommunications by an operator in a separate physical location from the patient: an early exploration into the feasibility of telestenting (the REMOTE-PCI study). EuroIntervention. 2017 Jan 20;12(13):1569-1576. doi: 10.4244/EIJ-D-16-00363.
- Pugin F, Bucher P, Morel P. History of robotic surgery: from AESOP(R) and ZEUS(R) to da Vinci(R). J Visc Surg. 2011 Oct;148(5 Suppl):e3-8. doi: 10.1016/j.jviscsurg.2011.04.007. Epub 2011 Oct 4. No abstract available.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 104-07972
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Percutaneous Coronary Intervention
-
NCT00870038UnknownTo Achieve an Early Reendothelialization at the Expense of Low Restenosis: The EREMUS Study (EREMUS)Percutaneous Coronary Intervention | Angioplasty, Transluminal, Percutaneous Coronary
-
NCT05340998CompletedPercutaneous Coronary Intervention | Coronary Angiography
-
NCT06502938Not yet recruitingPercutaneous Coronary Intervention
-
NCT03809273CompletedPercutaneous Coronary Intervention
-
NCT04103086UnknownPercutaneous Coronary Intervention
-
NCT04047199UnknownPercutaneous Coronary Intervention
-
NCT02691819UnknownPercutaneous Coronary Intervention
-
NCT04664140CompletedPercutaneous Coronary Intervention | Coronary Physiology
-
NCT05981859CompletedPercutaneous Coronary Intervention
-
NCT00751231CompletedPercutaneous Coronary Intervention
Clinical Trials on Remote treatment of PCI.
-
NCT07314879Completed
-
NCT01866033Completed
-
NCT05550103Recruiting
-
NCT04291638Completed
-
NCT04332003Withdrawn
-
NCT03930940CompletedIntracerebral Hemorrhage
-
NCT03045055Not yet recruiting
-
NCT06638944RecruitingStroke | Parkinson Disease | Dysphagia