Feasibility of Confocal Laser Microscopy (CLM)in the Computed Tomography-guided Needle Biopsy of Pulmonary and Mediastinal Lesions

May 12, 2014 updated by: Dr. Tiberiu Shulimzon MD, Sheba Medical Center

Feasibility of Confocal Laser Microscopy CLM in the Computed Tomography-guided Needle Biopsy of Pulmonary and Mediastinal Lesions

The hypothesis of this proposal is that needle confocal laser microscopy (nCLM) may improve the yield of trans thoracic needle biopsy (TTNB) of lung or mediastinal lesions by differentiating between viable and necrotic tissue. This may reduce the number of biopsy attempts and eventually the complication rate of the procedure.

Study Overview

Detailed Description

CT guided needle biopsy (TTNB - trans thoracic needle biopsy ) of pulmonary lesions is a well established diagnosis technique in pulmonology. It is most suitable for peripheral lung lesions with a diameter greater than 2 cm and for the diagnosis of a mediastinal mass. In these situations the diagnosis yield may reach up to 90% . However in smaller or "non homogenous" lesions (as to CT imaging) the yield lowers to only 60% .As usually there is no rapid onsite specimen pathologic examination (ROSE) a number of attempts (passages) are performed in order to receive a good quality sample. The complication rate of TTNB (pneumothorax or bleeding) is relatively high ( up to 15% and 5% respectively). Necrosis is a common feature of rapid growing tumors and may significantly impair the histopathological diagnosis and thus lowering the TTNB yield. Optimization of the needle position into a viable tissue area of the lesion is imperative as to improve the yield of the TTNB technique.

CLM is an emergent technique in which a low power laser excites the autofluorescence or the induced fluorescence (by intravenous. administration) of tissues. . CLM is capable of to provide the examiner with near histopathological quality tissue imaging serving as an "optical biopsy". The technique is well established in dermatology and gastroenterology (via endoscopes) and serves in distinguishing cellular abnormalities in inflammatory, premalignant and malignant disorders. Recently pulmonary applications were described allowing for alveolar real time vision (alveoscopy) . While used through the working channel of different endoscopes it is named probe CLE ( probe confocal laser endomicroscopy).

Needle based confocal laser endomicroscopy (nCLE) was studied in the diagnostic of pancreatic masses and celiac/mediastinal lymph nodes .A probe CLE was introduced through a 19 G needle biopsy by endoscopic guidance into the lesion. Imaging started following intravenous administration of fluorescein .Preliminary results showed good quality of imaging and also a remarkable positive predictive value of pictures details in normal versus disease tissue .

The CLM probe has a diameter of 0,85 mm and may be introduced through a 19 G trans thoracic biopsy needle by replacing the stylet. Its field of view is of 320 µm , lateral resolution 3,5 µm , depth of 50 µm and length of 4 m. the TTNB will be performed according to the standard protocol at the Interventional Radiology Department at Sheba, following the intravenous administration of fluorescein. This protocol is described further .

After receiving consent, the patient lies on the CT table and the skin over the chest lesion is cleaned and draped in the usual sterile fashion. Local anesthesia is delivered with Lidocaine 2% to the skin and pleura and a 19G introducer needle is advanced to the lesion border under CT vision. Via this introducer a 20G core biopsy needle is advanced and 3-6 biopsies are performed. Following the procedure another CT scan is performed to evaluate for any immediate complications and the patient is transferred to a recovery room for 2 hours observation. Before discharge a chest radiography is performed to evaluate for possible pneumothorax or bleeding.

The use of fluorescein in pulmonary medicine was described in CLM through bronchoscope.The protocol consists of the injection of 10 ml of 0,25% of sodium fluorescein solution through a venous catheter and immediate rinsing with 10 ml saline solution 0,9%. This differs from ophthalmologic or gastroenterologic protocols as using a diluted solution. Imaging may start 1 minute following the injection and last up to 10 minutes. We expect lower side effects from fluorescein use as those described in retinal angiography. Fluorescein stains the microvasculature, extracellular matrix and cytoplasmic component (but not cell nuclei) of epithelium and diffuses across capillaries into extravascular spaces. CLM with fluorescein can be used to diagnose neoplasia by presenting abnormal vessels (increased size and arborization) . Increased leakage owing to neovascularization may also be diagnosed. On site rapid cytological examination (ROSE) will be the standard for biopsy quality.

Study Type

Interventional

Enrollment (Anticipated)

10

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 80 years (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • patients aged between 18 and 80 referred for TTNB due to lung or mediastinal lesions. Both genders will be enrolled with new diagnosed mediastinal or lung masses by chest imaging (chest radiography or computed tomographyCT)

Exclusion Criteria:

  • known allergy to anesthetic medication, known allergy to fluorescein, inability to lie on the CT bed examination or cardiovascular instability as decided by the principal investigator.Pregnant women' children or debilitated patients will not be included

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: DIAGNOSTIC
  • Allocation: NA
  • Interventional Model: SINGLE_GROUP
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
EXPERIMENTAL: One arm ; CLM use in TTNB
  1. to determine the feasibility of using the CLM in performing TTNB of thoracic and mediastinal lesions
  2. to obtain imaging criteria for distinguishing viable from non viable (necrotic) tissue and normal versus abnormal (inflammatory/malignant) lesions. On site rapid cytological examination (ROSE) will be the standard of biopsy quality.
  3. the results will be compared to historic data of standard biopsies as to yield and quality of sampling
Other Names:
  • CT guided trans thoracic needle biopsy with confocal laser microscopy assisstance

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
The presence of viable tissue at CLM as a marker of accurate histological diagnosis
Time Frame: 24 months
The presence of necrotic tissue in lung or mediastinal biopsies impare the quality of histological diagnosis. CLM may help in distinguishing between viable and necrotic tissue in real time.
24 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Tiberiu R Shulimzon, Interventional Pulmonology The Pulmonary Institute Sheba Medical Center

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

January 1, 2014

Primary Completion (ANTICIPATED)

December 1, 2015

Study Completion (ANTICIPATED)

December 1, 2015

Study Registration Dates

First Submitted

October 27, 2013

First Submitted That Met QC Criteria

November 7, 2013

First Posted (ESTIMATE)

November 8, 2013

Study Record Updates

Last Update Posted (ESTIMATE)

May 13, 2014

Last Update Submitted That Met QC Criteria

May 12, 2014

Last Verified

May 1, 2014

More Information

Terms related to this study

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Pulmonary and Mediastinal Lesions

3
Subscribe