STUDY OBJECTIVES The primary objective of this clinical study is to assess the value of low-dose CEDEM in comparison with CE-MRI. The diagnostic accuracy in breast cancer detection of low dose CEDEM will be evaluated.
Investigator plans to explore the diagnostic quality of 4 standard view bilateral dual energy subtracted images compared to CE-MRI in a blinded reader study. A goal is to evaluate, whether sensitivity and specificity of low-dose CEDEM are comparable with breast MRI.
Subjects will be asked before diagnostic workup to participate in this clinical study. Approximately 80 subjects scheduled for a diagnostic CE-MRI (i.e., based on screening mammography classified as BI-RADS® 0, 4 or 5), will be eligible to participate in this study and will undergo a follow up 4 view bilateral low dose contrast enhanced mammography procedure.
Radiologically, subjects included in the study population will have even distribution of masses, clusters of microcalcifications, and architectural distortions as given by the nature of breast cancer development.
The study population will include all breast compositions. Diagnostic CE-MRI Examination If eligible, subjects with a positive or incomplete screening mammogram (BI-RADS 0, 4 or 5) will undergo a CE-MRI of the breast. MRI examinations will be performed on a 3 Tesla scanner (Tim trio, Siemens) with a dedicated 16 channel breast coil. A combination of high temporal and high spatial resolution imaging protocol will be used. All patients will be examined in the prone position and contrast agent (0.2mmol / body weight, GD-DOTA) will be administered i.v. as a bolus followed by a 20 ml saline flush.
Both exams (CEDEM and CE-MRI) will be scheduled in the second week of the menstrual cycle in premenopausal women. Each suspicious lesion will undergo needle or surgical biopsy (after completion of the CEDEM+PRIME procedure). Imaging findings will be compared with findings of histology.
Diagnostic CEDEM+PRIME If eligible, subjects with a completed MRI procedure will undergo a 4 standard view (CC, MLO) bilateral CEDEM examination. Due to use of the grid-less PRIME acquisition technology the AGD is limited and lies in the range of a standard mammogram. The high energy images will be acquired with the titanium filter. All acquired images - including the unprocessed images - will be collected. Recombined CEDEM images will be created offline. Contrast agent is injected as a bolus of 2 ml/kg body weight of non-ionic iodine contrast media with a power injector at a rate of 3.5ml/s followed by a 25ml saline flush.
The CEDEM diagnostic procedure will be performed not later than 7 days and at least 24 hours after the CE-MRI procedure.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Wien, Austria, 1090
- Allgemeines Krankenhaus Wien
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Females at least 21 years of age or older
- A screening mammogram classified as BI-RADS® 0, 4 or 5 followed by a diagnostic CE-MRI and a histological verification of a given lesions either by needle biopsy or open surgery
- Signed informed consent after receiving a verbal and written explanation of the purpose and nature of this clinical study
Exclusion Criteria:
- Pregnant or possible pregnant as well as lactating women
- Have mammographic evidence of previous breast surgery, prior radiation to the breast, needle projection or pre-biopsy markings are evident on the mammogram
- Breast implants
- Patients who will undergo neo-adjuvant chemotherapy (BI-RADS 6)
- Inmates or mentally disabled patient.
- Renal insufficiency or contrast agent allergy
- Patients who participated in other clinical studies within the last 12 months
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
---|---|
Other: CEDEM
diagnostic contrast enhanced Dual Energy mammograms after Iodine based contrast media administration compared to CE MRI
|
The CEDEM application requires the intravenous injection of iodide contrast agents.
For each projection view (CC, MLO) a low and a high energy x-ray image will be acquired after Iodine based contrast medium administration.
Patient will undergo CE MRI procedure.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Diagnostic accuracy of contrast enhanced dual energy mammography for breast cancer diagnosis
Time Frame: 24 months
|
Difference in accuracy of 11% comparing a 4-view contrast-enhanced dual energy imaging to CE-MRI assuming 11% discordant rate in the diagnosis
|
24 months
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
sensitivity, specificity and the lesion-level ROC area.
Time Frame: 24 months
|
The ROC area will be estimated from the BI-RADSS scores assigned by the readers to each suspicious lesion.
The BI-RADS scores assigned by the readers in the interpretation of a CEDEM lesion will be used for the CEDEM+PRIME ROC area; the BI-RADS scores assigned by the readers in the interpretation of a CE-MRI case per lesion will be used for the CE-MRI ROC area.
A receiver operating characteristic (ROC), or ROC curve, is a graphical plot that illustrates the performance of a binary classifier system as its discrimination threshold is varied.
The curve is created by plotting the true positive rate (TPR) against the false positive rate (FPR) at various threshold settings
|
24 months
|
Collaborators and Investigators
Sponsor
Collaborators
Study record dates
Study Major Dates
Study Start
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimate)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- C00215154
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Breast Cancer Diagnosis
-
Institut Paoli-CalmettesRecruiting
-
RenJi HospitalNot yet recruitingBreast Cancer | Breast Cancer Diagnosis
-
Sidney Kimmel Comprehensive Cancer Center at Johns...Terminated
-
McMaster UniversityCompletedBreast Cancer Screening | Breast Cancer Diagnosis | MRI Guided Breast BiopsyCanada
-
Peking Union Medical College HospitalRecruitingBreast Cancer Screening | Breast Cancer DiagnosisChina
-
University of MichiganCompleted
-
AB-CT - Advanced Breast-CT GmbHCRO Dr. med. Kottmann GmbH; RQM+ (Germany) GmbHRecruitingBreast Cancer DiagnosisNetherlands, Germany
-
University of Southern CaliforniaNational Cancer Institute (NCI)Not yet recruitingBreast CarcinomaUnited States
-
Koning CorporationCompletedBreast Cancer Diagnosis
-
Ankara Education and Research HospitalCompletedDiagnosis | Axilla; BreastTurkey
Clinical Trials on CONTRAST ENHANCED DUAL ENERGY (CEDEM)
-
University of Southern CaliforniaNational Cancer Institute (NCI)CompletedBreast CarcinomaUnited States
-
American College of RadiologyGE Healthcare; Breast Cancer Research FoundationRecruitingBreast CancerUnited States
-
Memorial Sloan Kettering Cancer CenterGE HealthcareCompletedBreast CancerUnited States
-
University of Alabama at BirminghamCompleted
-
University of Maryland, BaltimoreRecruiting
-
University Hospital, Strasbourg, FranceTerminatedFor Oncologic Patients | Potentially Operable Lung Tumor | With a Recent (Less Than 1 Month) VQ Scan | For Lung Transplant Recipients | Single of Bilateral Lung Transplant | From 5 Months Onwards | With Recent (Less Than 1 Month) Respiratory Functional ExplorationsFrance
-
Thomas Jefferson UniversityCompletedBreast NeoplasmsUnited States
-
Rigshospitalet, DenmarkNot yet recruitingTomography, X-Ray Computed | Bowel; Ischemic, Chronic | Dual-energy CT
-
UNC Lineberger Comprehensive Cancer CenterCompletedKidney CancerUnited States
-
Sameer AvasaralaRecruiting