Placement Of Cardiac PacemaKer Trial (POCKET)-RCT (POCKET-RCT)

October 11, 2016 updated by: Peter Magnusson, Region Gävleborg

Aim: To compare patient satisfaction with intramuscular placement of a pacemaker pocket to subcutaneous placement.

Patients will be randomized (approximately half i each group) to receive the pacemaker device either subcutaneously (current practise) or intramuscular)

Study Overview

Detailed Description

Background: Implantation of a cardiac pacemaker may be indicated in patients with a significant bradycardia according to current guidelines.1 Annually, around 691 pacemakers per million inhabitants are implanted in Sweden.2 A pacemaker system consist of one or two leads connected to a device that is implanted beneath the collarbone.3,4 Vessel access is typically on the left side through the cephalic, axillary or subclavian vein. The pacemaker is inserted into a pocket. Routinely this pocket is just above the pectoral fascia (subcutaneously) or sometimes in skinny patients with a small amount of subcutaneous fat between the pectoral muscular layer (intramuscular). Even though technical developments have diminished the size of pacemakers markedly over time, complications due to superficial implants still do occur.5,6 Occasionally the device erode the skin and a complete extraction of the system is necessary. More frequently patients complain about the device being too superficial which sometimes require surgical repositioning of the device.5,6 The device may create discomfort, pain, and unsightly.5,6 The lateral corner of the device may disturb the shoulder movement, sleep and the leads can be turned within the pocket (Twiddler's syndrome). Minor branches from the supraclavicular nerves may result in discomfort. When vessels from the subcutaneous adipose tissue are distorted, extensive bruising may be bothersome and a large hematoma is a known risk of infection. The perfusion in the operation area is diminished and the amount of fat over device may be reduced to an extent that was unexpected at first implant. The change of device due to battery depletion can result in even less surrounding tissue. An alternative approach is an intramuscular placement of the device.7,8 This has been advocated by Kistler et al based on personal experience but there are neither systematic observational studies nor randomized controlled studies to support this approach.6 To the knowledge of the investigators no randomized controlled trial have addressed the question about the optimal placement of a bradycardia pacemaker.

Aim: To compare patient satisfaction with intramuscular placement of a pacemaker pocket to subcutaneous placement.

Research questions: Primary outcome: Is there a different in patient overall satisfaction (on a Visual Analog Scale (VAS)-scale between 0-10) with the pocket between patients with intramuscular placement of a pacemaker pocket and patients with subcutaneous placement at 24 months after implant? Secondary outcomes: Complications (revision of pocket, dislodgement, hematoma requiring surgery, infection (local/systemic). Patient reported satisfaction at 1, 12, 24 months (overall satisfaction, pain, discomfort, degree of unsightly look, movement problems due to device, and sleep problems due to device). Pacemaker nurse judgement of unsightly look of the pacemaker pocket (month 1, 12, and 24). Picture of pocket (1, 12, 24 months) judged by an experienced implanting physician who is blinded to the group allocation and has not operated on the patient.

Method: Power analysis: the investigators performed a power analysis based on expectations and clinical experience of the research group. Figure 1 shows two hypothetical truncated lognormal distributions of patient overall satisfaction with the pacemaker, where median overall satisfaction of the intramuscular and the subcutaneous group are assumed to be 2.4 and 4, respectively. Monte Carlo-simulations from these distributions showed that a total of 200 patients, 100 in each arm, would yield a statistical power of 90% for Mann-Whitney U-test at a significance level of 0.05.

In total, 200 consecutive patients with indication of are expected to be randomized in the study (100 patients in each arm, intramuscular vs subcutaneously). In Region Gavleborg , the annual primary implant volume of bradycardia pacemakers is approximately 220.

Figure 1. Assumed distributions of patient overall satisfaction in the power analysis, as measured by an visual analogue scale where 0 means "very satisfied" and 10 means "very dissatisfied". The intramuscular group is assumed to follow a lognormal distribution with mean 1.5 and standard deviation of 1, on the logarithmic scale. The subcutaneous patients are assumed to follow a lognormal distribution with mean 1.5 and standard deviation of 1, on the logarithmic scale.

Randomization: At the time of implant 1:1 randomization (100 patients in each group) to either subcutaneous (usual care) or intramuscular implant, in blocks with random block sizes. The randomization is performed by a statistician with no insight in the ongoing clinical work and patients' group allocation is revealed for implanting physician by the assistant nurse at the start of the surgical procedure. Randomization procedure: stratification (age strata: ≤65 years and >65 years) and sex (female, male); totally 4 strata). Consecutive group allocations will be stored in sealed opaque envelopes that will be opened at the time of starting the implant procedure.

Inclusion: Indication of a bradycardia pacemaker (DDDR, VVIR). Exclusion: Cardiac Resynchronisation Therapy Pacemaker (CRTP), Cardiac Resynchronisation Therapy Defibrillator (CRTD), implantable cardioverter defibrillator (ICD). Very skinny patient deemed as such by implanting physician to clearly benefit from intramuscular implant.

Surgical procedure: Standard procedure and vascular access by each operator's preference. Blunt dissection of the pocket.

Statistical methods: For comparisons between groups: Mann-Whitney U-test. For test of changes in VAS-estimations between 1, 12, and 24 months: pair-wise Wilcoxon signed-rank test.

Informed consent: Written and oral information by nurse/physician before implant.

Ethical approval: Approved by Uppsala Regional Committee. Clinical Trial Registration: Registration before start of study.

Variables:

Clinical variables: age, sex, coronary artery disease, open-heart surgery, diabetes, kidney disease Pacemaker system: (VVIR, DDDR), brand, model (lead(s) and device. Vascular access: (cephalic, axillary, subclavian vein), fluro-time, procedure time Periprocedural analgetics (dosage): alfentanil, morphine, diazepam, paracetamol Pre och post-operative anticoagulant medication (dosage and withdrawal with respect to procedure: acetylic acid, clopidogrel, ticagrelor, dual oral anticoagulants, warfarin, low-molecular weight heparin) Preoperative current medication: (psychoactive drugs, betablockers, corticosteroids, inflammatory modulating drugs Outcome measurements: Patient satisfaction (overall, chronic pain, discomfort, degree of unsightly look, movement disorder due to device, sleep problems due to device) scale 0-10 (10 worst) Paper questionnaire at 1,12,and 24 months. Patient knowledge if device was intramuscular or subcutaneously implanted at 24 months.

Pacemaker nurse judgement: unsightly look (0-10, 10 worst). Physician evaluation (blinded to the patient and not operator in the study): photo of pocket (1, 12, 24 months) scale 0-10 (10 worst).

Complications requiring surgery: pocket revision, dislodgment, hematoma requiring surgery, infection (local, systemic), pneumothorax, pericardial effusion requiring drainage, other.

Clinical perspectives: The surgical approach to the pacemaker pocket needs to be evaluated. The optimal approach including patient reported outcomes may result in more long-term satisfaction and may reduce the need for pocket revisions.

Study Type

Interventional

Enrollment (Anticipated)

200

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Child
  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Indication of a bradycardia pacemaker (DDDR, VVIR).

Exclusion Criteria:

  • CRTP, CRTD, ICD.
  • Very skinny patient deemed as such by implanting physician to clearly benefit from intramuscular implant.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: subcutaneous pacemaker
The patients who are randomized to receive a subcutaneously implanted pacemaker
During implant of a pacemaker the device is either implanted subcutaneously or intramuscular
Active Comparator: intramuscular pacemaker
The patients who are randomized to receive an intramuscular implanted pacemaker
During implant of a pacemaker the device is either implanted subcutaneously or intramuscular

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
patient overall satisfaction
Time Frame: 24 months
Is there a different in patient overall satisfaction (on a VAS-scale between 0-10) with the pocket between patients with intramuscular placement of a pacemaker pocket and patients with subcutaneous placement at 24 months after implant?
24 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
complications due to pacemaker procedure
Time Frame: 24 months
Complications (revision of pocket, dislodgement, hematoma requiring surgery, infection (local/systemic). Measurement: number of each event (n)
24 months
pain problems due to pacemaker device
Time Frame: 24 months
Patient reported pain at 1, 12 and 24 months on a VAS-scale 0-10.
24 months
discomfort due to pacemaker device
Time Frame: 24 months
Patient reported discomfort at 1, 12, 24 months on a VAS-scale 0-10.
24 months
Patient own judgement of degree of unsightly look due to pacemaker device
Time Frame: 24 months
Patient reported satisfaction at 1, 12, 24 months on a VAS-scale 0-10.
24 months
movement problems due to device
Time Frame: 24 months
Patient reported satisfaction at 1, 12, 24 months on a VAS-scale 0-10.
24 months
sleep problems due to device
Time Frame: 24 months
Patient reported satisfaction at 1, 12, 24 months on a VAS-scale 0-10.
24 months
Pacemaker nurse judgement of unsightly look of the pacemaker pocket
Time Frame: 24 months
Pacemaker nurse judgement of unsightly look of the pacemaker pocket (month 1, 12, and 24) on a VAS-scale 0-10.
24 months
Picture of pocket
Time Frame: 24 months
Picture of pocket (1, 12, 24 months) judged by an experienced implanting physician who is blinded to the group allocation and has not operated on the patient on a VAS-scale 0-10.
24 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Per Liv, Ph.D, Centre for Research and Development Gavleborg/Uppsala University

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

October 1, 2016

Primary Completion (Anticipated)

December 1, 2017

Study Completion (Anticipated)

June 1, 2019

Study Registration Dates

First Submitted

October 1, 2016

First Submitted That Met QC Criteria

October 11, 2016

First Posted (Estimate)

October 13, 2016

Study Record Updates

Last Update Posted (Estimate)

October 13, 2016

Last Update Submitted That Met QC Criteria

October 11, 2016

Last Verified

October 1, 2016

More Information

Terms related to this study

Other Study ID Numbers

  • 2016371

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

Yes

IPD Plan Description

IPD will be available (without identification of each individual) upon request by the journal (i.e Supplement file)

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.