Optimizing Volunteer Comfort for Transcranial Electrical Stimulation (TES): An Assessment (TES)

Optimizing Volunteer Comfort for Transcranial Electrical Stimulation (TES): An Assessment of Sensor (Electrode) Preparations - PARTS A, B and C

Transcranial electrical stimulation (TES) utilizing weak electrical fields (<5 milliamps of current - as proposed in the present pilot study) is an extremely safe therapeutic technique in use for over 40 years. During that time, TES has never been associated with a serious adverse event in a research setting nor a serious reported adverse event in a clinical setting. The main side effect associated with TES is irritation of the skin beneath the electrodes (as is commonly found from similar preparations used for polysomnography). The purpose of this pilot study is to identify the type of electrode preparation that maximizes subject comfort during transdermal/transcranial electrical stimulation (TES) using the NeuroConn DC Plus Stimulator.

Study Overview

Status

Enrolling by invitation

Detailed Description

In this study, volunteers will be divided into groups based on the nature of the stimulation waveform utilized (DC 0.75 Hz, modified AC 0.75 Hz, AC sinusoidal 3.0 Hz or pulsed stimulation of up to 500 ms duration). These waveforms were chosen based on the physiology of slow-wave sleep (SWS). Ultimately, the goal is to use TES during sleep to enhance the slow-wave activity (SWA) of sleep. Slow-wave sleep is characterized by two main frequency bands with differing underlying physiologies: (1) slow oscillation activity with a peak of 0.75 Hz, and (2) delta activity with a peak of approximately 3.0 Hz. Therefore, in future studies, the plan is to stimulate at one or both of these frequencies. The endogenous slow activity of the brain consists of electrical fields of "alternating current" with periods of relative cellular depolarization and periods of relative cellular hyperpolarization. The goal is to enhance this endogenous behavior with transcranial electrical stimulation at the two major slow- wave frequencies (0.75 Hz, 3.0 Hz), or using a pulsed stimulation paradigm to induce slow wave activity.

Study Type

Interventional

Enrollment (Anticipated)

75

Phase

  • Not Applicable

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 39 years (ADULT)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

All

Description

Inclusion criteria - healthy adult men and non-pregnant, non-lactating women aged 18-39 years, inclusive.

Exclusion criteria - The following exclusion criteria apply to all volunteers, are consistent with those used in our other sleep studies, and are applied in this protocol in order to obtain a sample of volunteers who are likely to be representative of future study populations:

  • Self-reported habitual nightly sleep amounts outside the target range of 6-9 hours (i.e., less than 6 hours per night or more than 9 hours per night, on average):
  • Nighttime lights-out times earlier than 2100 hours on average during weeknights (Sunday through Thursday) for the past month
  • Morning wake-up times later than 0900 on average during weekdays (Monday through Friday) for the past month.
  • History of cardiovascular disease (to include but not limited to arrhythmias, valvular heart disease, congestive heart failure, history of sudden cardiac death or myocardial infarction)
  • Reported habitual napping (> 3 times a week in conjunction with normal sleep habits)
  • Resting blood pressure above 140/90
  • Resting pulse > 110
  • Neurologic disorder (to include but not limited to epilepsy or another seizure disorder, amnesia for any reason, hydrocephalus, MS, narcolepsy or other sleep disorders)
  • Kidney disease
  • History of psychiatric disorder requiring hospitalization or psychiatric medication for any length of time
  • Beck Depression Inventory score of 14 or above
  • Underlying pulmonary disease requiring daily inhaler use
  • Regular nicotine use (or addiction) (defined as more than 1 cigarette or equivalent per week) within the last 1 year
  • Positive nicotine/cotinine screen as determined by NicCheck™ I test strips
  • Heavy alcohol use to be determined by the PI or his/her representative (minimum limit to define heavy alcohol use is 14 drinks per week)
  • Use of other illicit drugs (to include but not limited to benzodiazepines, amphetamines, cocaine, marijuana)
  • Known liver disease or liver abnormalities as determined by a laboratory test
  • Self-reported history of caffeine use in excess of 400 mg (approximately 8 caffeinated sodas or 3-4 cups of coffee) per day on average
  • Pregnancy (females)
  • Inability to read and sign consent
  • Use of certain medications (including use of vitamins or supplements), to be determined on a case-by-case basis by the examining study licensed physician.
  • BMI ≥ 30 (Obese Class I or greater)
  • The PI also maintains the prerogative to disqualify a volunteer if it is deemed that the volunteer's participation would be unsafe for the volunteer or staff or would be disruptive to study conduct.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: BASIC_SCIENCE
  • Allocation: NON_RANDOMIZED
  • Interventional Model: SEQUENTIAL
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
ACTIVE_COMPARATOR: Part A, Group 1
Forearm stimulation during wake (study PART A) - electrode placement = volar surface of forearm, 2 electrodes (cathode and anode): Group 1 will receive forearm stimulation at 0.75 Hz with an oscillating direct current (DC) waveform while awake.
NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.
ACTIVE_COMPARATOR: Part A, Group 2
Forearm stimulation during wake (study PART A) - electrode placement = volar surface of forearm, 2 electrodes (cathode and anode): Group 2 will receive forearm stimulation at 0.75 Hz with a modified alternating current (AC) waveform while awake.
NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.
ACTIVE_COMPARATOR: Part A, Group 3
Forearm stimulation during wake (study PART A) - electrode placement = volar surface of forearm, 2 electrodes (cathode and anode): Group 3 will receive forearm stimulation at 3.0 Hz with an alternating current (AC) sinusoidal waveform while awake.
NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.
ACTIVE_COMPARATOR: Part B, Group 4
Scalp stimulation during sleep (study PART B) - bilateral electrode pairs placed on the upper forehead near the midline (F3 and F4) and adjacent to the ear in the mastoid region (M1 and M2). roup 4 will receive scalp stimulation at 0.75 Hz with an oscillating direct current (DC) waveform during sleep.
NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.
ACTIVE_COMPARATOR: Part B, Group 5
Scalp stimulation during sleep (study PART B) - bilateral electrode pairs placed on the upper forehead near the midline (F3 and F4) and adjacent to the ear in the mastoid region (M1 and M2). Group 5 will receive scalp stimulation at 0.75 Hz with a modified alternating current (AC) waveform during sleep.
NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.
ACTIVE_COMPARATOR: Part B, Group 6
Scalp stimulation during sleep (study PART B) - bilateral electrode pairs placed on the upper forehead near the midline (F3 and F4) and adjacent to the ear in the mastoid region (M1 and M2). Group 6 will receive scalp stimulation at 3.0 Hz with an alternating current (AC) sinusoidal waveform during sleep.
NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.
ACTIVE_COMPARATOR: Part C, Group 7
Pulsed Stimulation: Group 7 (Part C)will receive a series of brief stimulations of up to 500 millisecond duration and of up to 5 milliamperes of current, using either metal electrodes or sponge electrodes as stimulating electrodes.
NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Sensation scale
Time Frame: Day 1
participants indicate level of sensation on a scale from 1-10; Sensation Scale: 0 to 10 where 10 indicates experiencing severe discomfort; 0 indicates no discomfort
Day 1
Erythema observation
Time Frame: Day 1
observation of skin erythema following removal of electrodes: At baseline observation for presence of skin lesions/pathology; following stimulation observation of a change or no change in skin lesions/pathology from baseline
Day 1

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (ACTUAL)

May 24, 2014

Primary Completion (ANTICIPATED)

February 12, 2024

Study Completion (ANTICIPATED)

February 12, 2026

Study Registration Dates

First Submitted

November 12, 2019

First Submitted That Met QC Criteria

July 13, 2020

First Posted (ACTUAL)

July 16, 2020

Study Record Updates

Last Update Posted (ESTIMATE)

February 9, 2023

Last Update Submitted That Met QC Criteria

February 6, 2023

Last Verified

February 1, 2023

More Information

Terms related to this study

Other Study ID Numbers

  • WRAIR #1927

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Sleep

Clinical Trials on transcranial electric stimulation

3
Subscribe