- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05325060
Navigated Versus Convention Total Knee Arthroplasty (iNAV)
Randmised Controlled Trial Comparing Electromagnetically Navigated Versus Conventional Mechanically Aligned Total Knee Arthroplasty
Study Overview
Status
Detailed Description
Participants Patients were identified by members of the research team from TKA surgical waiting lists. Patients were invited to participate if they had osteoarthritis of the knee suitable for TKA, were able to provide informed consent, and were aged 18 or over. There were no specific limits imposed on the degree of preoperative coronal or sagittal deformity.
Randomization Overall, 272 patients were screened between July 2007 and August 2010. Of the 272 screened patients, 14 were excluded for other medical reasons, whereas 58 participants decided that they did not want to participate in a research study. The remaining 200 patients were recruited and consented to the study giving a recruitment rate of 74%. Patients were randomized in a 1:1 ratio to either conventional TKA or navigated TKA using a web based computer-generated random number table. Randomization was based on the order of their recruitment and stratified by surgeons to prevent surgeon bias and ensure that similar numbers of patients in each groups were allocated to each surgeon. Randomization was successful in assigning equal preoperative patient demographics between the groups.
Ethical Approval The study was approved by the Glasgow Royal Infirmary Local Ethics Committee and the University of Strathclyde Ethics Committee (07/S0704/6) and approved by the NHS GGC R&D department before commencement of the study.
Surgical Procedure All patients received a cemented posterior stabilized NexGen LPS Flex (Zimmer, Warsaw, Indiana, USA). Participants randomized to the conventional group received a TKA implanted using standard instrumentation, whereas those randomized to the navigated group had surgery using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA). The iNav EM system is imageless and uses small reference frames attached to the femur and tibia which are readily incorporated in the primary incision. There is then a process of joint registration which maps the surface anatomy of the joint. All surgeries including joint surface registration were carried out by, or under the direct supervision of, one of two knee arthroplasty surgeons. Alignment targets were similar in both groups with a neutral HKAA and the aim to implant both femur and tibial components perpendicular to this in the coronal plane.
Ligament balancing was carried out using clinical assessment during the surgical procedure in both groups. In the navigated group, additional information was provided by the system with real-time feedback of the gap in mm between the femoral and tibial component and of the overall HKAA during varus and valgus stress.
Primary outcome measurement Post-operative CT scans were used to determine the accuracy of implantation. CT scan analysis was conducted using Mimics 12.0 software (Materialise, Leuven, Belgium). Measurements of the femoral and tibial component position in the coronal (varus/valgus), sagittal (flexion/extension) and axial (rotational) planes were made. The overall mechanical alignment was also calculated from the addition of the femoral and tibial coronal angles. The combined component rotation was calculated from the addition of the femoral and tibial rotation angles. The rotations were measured using the methods detailed in Berger et al (1998). In the coronal plane the investigators aimed to position both femoral and tibial implants at 90° to the mechanical axis. In the sagittal plane the investigators aimed to position the femoral component with a 5° slope relative to the mechanical axis, in line with the anterior cortex of the distal femur. The tibial component was aimed to be positioned at a 7° slope, as per the manufacturer's guidelines. For femoral rotation the investigators aimed to implant the femoral component in line with the surgical trans-epicondylar axis of the femur. The reference for tibial rotation was a line from the geometric center of the tibia to the center of the tuberosity. Rotational measurements were calculated from a perpendicular line drawn from the posterior surface of the implant. As the tuberosity is 18° externally rotated, the investigators considered an 18° internal rotation of the implant to be a neutral position. (No obvious deformities of the tibia or previous fractures were noted in the study cohort that could have influenced this value.) The investigators considered the desired mechanical axis alignment to be 0° with a range of ± 3°.
Patient-Reported Outcome Measures and Revisions Participants were followed up for 10 years after surgery, with clinical assessments by a blinded independent assessor; range of motion (ROM) was determined using a hand-held goniometer, and knee-specific outcome measures included the American Knee Society Score (AKSS) and Oxford Knee Scores (OKS) and the SF 36 score used as a general health measure (both physical and mental). Revision surgery was also assessed by analyzing the Scottish National Picture Archiving and Communication System. This image archiving system stores all imaging for patients undertaken in the National Health Service (NHS) in Scotland since 2008. It acts as a valuable resource for identifying patients lost to follow-up who have undergone revision surgery in other NHS hospitals in Scotland which may have not been identified.
Statistics A power calculation was performed based in data provided by a randomized controlled trial using infra red optical tracking systems. Bathis et al reported 96% of patients with mechanical leg alignment within 3° of neutral using navigation compared to just 78% with conventional instrumentation . In order to detect a difference of this magnitude with a power of 90% at alpha = 0.05, the investigators would require 82 patients per group, 164 in total. As the primary outcome measure was based on post-operative CT scan the investigators anticipated a higher than average loss to follow-up for the primary outcome measure. The investigators therefore allowed an additional 25% for loss to follow-up, giving a total of 103 patients in each group.
Statistical analysis was performed using SigmaPlot 11.0 (Systat Software Inc). To evaluate differences between the surgical groups either a two sample t test (normally distributed data) or a Mann Whitney test (non parametric data) was performed. A Chi Squared test was used to analysis the male: female ratio. A P value of less that 0.05 was considered significant.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Male or female subjects
- Subjects must be at least 18 years of age and there will be no maximum age limit. The subjects age must be considered suitable by the Investigator for a knee arthroplasty using either of the two systems available in the evaluation.
- Subjects, who are able to give voluntary, written informed consent to participate in this investigation and from whom consent has been obtained.
- Subjects, who, in the opinion of the investigator, are able to understand this investigation, co-operate with the investigation procedures and are willing to return to the hopsital for all the required post-operative follow-ups.
- Subjects who require a knee arthroplasty for primary surgical management of the idiopathic osteoarthritis.
- Subjects, who in the opinion of the Investigator, are considered to be suitable for treatment with a NexGen LPS Flex Total Knee Replacement.
Exclusion Criteria:
- Subjects who, in the opinion of the investigator, have an existing condition that would compromise their participation and follow-up in the study
- Subjects who require revision total knee arthroplasty surgery
- Subjects with any tibial deformity requiring tibial component augmentation.
- Subjects whom, in the opinion of the Investigator, require a constratined prosthesis.
- Subjects with inflammatory polyarthritis.
- Subjects with disorders of the feet, ankles, hips, or spine caising significant abnormal gait or significant pain.
- Subjects with osteoarthritis of the contralateral knee causing significant abnormal gait or significant pain.
- Subjects with poorly functioning contralateral total knee replacement causing significant abnormal gait or significant pain. Subjects with a well functioning contralateral total knee replacement will not be excluded.
- Subjects with neurological conditions affecting movement.
- Subjects with a pathology which, in the opinion of the Investigator, will adversely affect healing.
- Subjects with other disorders which, in the opinion of the Investigator, will/could impair rehabilitation.
- Contra-indications for the use of the device, as detailed in the package insert.
- Women who are pregnant
- Subjects who are known drug or alcohol abusers or with psychological disorders that could effect follow-up care or treatment outcomes.
- Subjects who are currently invovled in another clinical study with an investigational product.
- Subjects who are currently invovled in any injury litigation claims.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
---|---|
Experimental: Electromagentically navigated Total knee arthroplasty
Patients underwent total knee arthroplasty using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA). The system employs small reference frames attached to the femur and tibia which are incorporated within the primary surgical incision. A standard process of joint registration maps the surface anatomy of the joint. Alignment targets were similar in both groups with a neutral Hip-Knee-Ankle-Axis and the aim to implant both femur and tibial components perpendicular to this in the coronal plane. All patients received a cemented posterior stabilized NexGen LPS Flex TKA (Zimmer, Warsaw, Indiana, USA). |
The navigated group had surgery using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA) and the definitive implant used was NexGen LPS implant (Zimmer Inc, Warsaw, IN, USA), a fixed-bearing bicruciate-sacrificing total condylar implant using traditional instrumentation with no patellar resurfacing
|
Active Comparator: Conventional mechanically alligned Total knee arthroplasty
Participants randomized to the conventional group received a TKA implanted using standard instrumentation. All patients received a cemented posterior stabilized NexGen LPS Flex TKA (Zimmer, Warsaw, Indiana, USA). Alignment targets were similar in both groups with a neutral Hip-Knee-Ankle-Axis and the aim to implant both femur and tibial components perpendicular to this in the coronal plane. |
The conventional group received surgery using conventional instrumentation and jigs from the implant manufacturer (Zimmer Inc, Warsaw, IN, USA) and the definitive implant used was NexGen LPS implant (Zimmer Inc, Warsaw, IN, USA), a fixed-bearing bicruciate-sacrificing total condylar implant using traditional instrumentation with no patellar resurfacing
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Knee coronal plane allignment
Time Frame: 3 months post operatively
|
The primary outcome measure for this study was alignment within 3 degrees of neutral mechanical alignment at three months after surgery
|
3 months post operatively
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Oxford knee score
Time Frame: Up to 10 years post operatively
|
Patient reported outcome measure validated for total knee arthroplasty
|
Up to 10 years post operatively
|
American Knee Society Score
Time Frame: Up to 10 years post operatively
|
Patient reported outcome measure validated for total knee arthroplasty
|
Up to 10 years post operatively
|
Short Form 36 Health Survey Questionnaire (SF-36)
Time Frame: Up to 10 years post operatively
|
Validated self reported outcome measure of health
|
Up to 10 years post operatively
|
Range of motion
Time Frame: 10 years post operatively
|
Measured by research assistant post operatively using established techniques
|
10 years post operatively
|
All cause revision surgery
Time Frame: 10 years post operatively
|
Examines re-intervention rates for any cause post-operatively.
We defined revision using the United Kingdom National Joint registery definition of any intervention that results in the addition, removal or exchange of any component of the primary implant
|
10 years post operatively
|
Collaborators and Investigators
Sponsor
Publications and helpful links
General Publications
- Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP. Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty. 2005 Apr;20(3):282-8. doi: 10.1016/j.arth.2004.09.047.
- Chin PL, Yang KY, Yeo SJ, Lo NN. Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty. 2005 Aug;20(5):618-26. doi: 10.1016/j.arth.2005.04.004.
- Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res. 2005 Apr;(433):152-9. doi: 10.1097/01.blo.0000150564.31880.c4.
- Bolognesi M, Hofmann A. Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res. 2005 Nov;440:162-9. doi: 10.1097/01.blo.0000186561.70566.95.
- Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J. Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br. 2004 Jul;86(5):682-7. doi: 10.1302/0301-620x.86b5.14927.
- Clark AN, Hounat A, O'Donnell S, May P, Doonan J, Rowe P, Jones BG, Blyth MJG. Electromagnetic Navigated Versus Conventional Total Knee Arthroplasty-A Five-Year Follow-Up of a Single-Blind Randomized Control Trial. J Arthroplasty. 2021 Oct;36(10):3451-3455. doi: 10.1016/j.arth.2021.06.007. Epub 2021 Jun 12.
- Blyth MJ, Smith JR, Anthony IC, Strict NE, Rowe PJ, Jones BG. Electromagnetic navigation in total knee arthroplasty-a single center, randomized, single-blind study comparing the results with conventional techniques. J Arthroplasty. 2015 Feb;30(2):199-205. doi: 10.1016/j.arth.2014.09.008. Epub 2014 Sep 16.
- Smith JR, Rowe PJ, Blyth M, Jones B. The effect of electromagnetic navigation in total knee arthroplasty on knee kinematics during functional activities using flexible electrogoniometry. Clin Biomech (Bristol, Avon). 2013 Jan;28(1):23-8. doi: 10.1016/j.clinbiomech.2012.09.006. Epub 2012 Oct 18.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- RN07OR001
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Arthroplasty, Replacement, Knee
-
Fondazione Don Carlo Gnocchi OnlusCompletedArthroplasty, Replacement, Knee | Arthroplasty, Replacement, HipItaly
-
Bornholms RegionskommuneCompletedArthroplasty, Replacement, Knee | Arthroplasty, Replacement, HipDenmark
-
Central DuPage HospitalTerminatedTotal Knee Replacement | Replacement, Total Knee | Arthroplasty, Knee ReplacementUnited States
-
Campus Bio-Medico UniversityRecruitingArthroplasty, Replacement, Knee | Arthroplasty, Replacement, HipItaly
-
SCRI Development Innovations, LLCWithdrawnArthroplasty, Replacement, Knee | Arthroplasty, Replacement, HipUnited States
-
Sunnybrook Health Sciences CentreActive, not recruitingArthroplasty, Replacement, Knee | Arthroplasty, Replacement, HipCanada
-
University of British ColumbiaThe Arthritis Society, Canada; Centre for Aging SMART; Centre for Advancing Health...Not yet recruitingArthroplasty, Replacement, Knee | Arthroplasty, Replacement, HipCanada
-
University Hospital, Strasbourg, FranceRecruitingArthroplasty, Hip Replacement | Arthroplasty, Knee ReplacementFrance
-
Henry Ford Health SystemConsumer Sleep SolutionsNot yet recruitingArthroplasty, Replacement, Knee | Arthroplasty, Replacement, HipUnited States
-
Haute Ecole de Santé VaudCompletedArthroplasty, Replacement, Knee | Arthroplasty, Replacement, HipSwitzerland
Clinical Trials on Electromagnetically navigated total knee arthroplasty
-
Singapore General HospitalCompleted
-
Aesculap AGB.Braun Surgical SAActive, not recruitingKnee Osteoarthritis | Prosthesis-Related Infections | Prosthesis Failure | Bone; Deformity, CongenitalSpain
-
Aesculap AGNot yet recruitingJoint Diseases | Osteoarthritis, Knee | Rheumatoid Arthritis of Knee | Posttraumatic ArthropathyGermany
-
University Hospital Schleswig-HolsteinDePuy InternationalUnknown
-
Charite University, Berlin, GermanyAesculap AGUnknownRevision Total Knee Arthroplasty Because of | Loosening | Instability | Impingement | or Other Reasons Accepted as Indications for TKA Exchange. | The Focus is to Determine the Precision of Joint Line Restoration in Navigated vs. Conventional Revision Total Knee ArthroplastyGermany
-
Technische Universität DresdenActive, not recruiting
-
Technische Universität DresdenMathys Ltd BettlachUnknownKnee Osteoarthritis
-
Jesus Moreta SuarezActive, not recruiting
-
Chang Gung Memorial HospitalUnknownComputer-assisted Navigation Versus Conventional Total Knee ReplacementTaiwan
-
Smith & Nephew, Inc.TerminatedDegenerative Arthritis of KneeUnited States, Australia