Coronary Non-slip Balloon Catheter in Patients With Coronary Artery Stenosis(CREST)

A Prospective, Randomized, Multicenter Clinical Trial of Non-slip Balloon Catheter in Patients With Coronary Artery Stenosis

This is a prospective, multicenter, randomized controlled clinical investigation aiming to evaluate the safety and effectiveness of non-slip balloon catheter for the treatment of patients with coronary artery stenosis.

Study Overview

Detailed Description

This trial is a prospective, multicenter, randomized controlled clinical trial. 200 subjects are expected to be recruited in 7 research centers in China and randomly divided into two groups according to the ratio of test group: control group = 1:1. The primary endpoint is the acute lumen gain.

All subjects receive clinical follow-up during hospitalization and 30 days after surgery.

Study Type

Interventional

Enrollment (Anticipated)

200

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

    • Shanghai
      • Shanghai, Shanghai, China, 200125
        • Recruiting
        • Renji Hospital Shanghai Jiaotong University School of Medicine
        • Contact:
          • Jun Bu

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Clinical Inclusion Criteria:

  1. Subjects aged≥18 years.
  2. Subjects with silent myocardial ischemia, symptomatic angina pectoris, or old myocardial infarction.
  3. Subjects who can undergo percutaneous coronary intervention (PCI).
  4. Subjects who are able to understand the purpose of the trial, participate voluntarily and indicate by signing the informed consent form that they recognize the risks and benefits described in the informed consent document and are willing to undergo clinical follow-up.

Angiography Inclusion Criteria:

  1. For subjects with single or double lesions, revascularization is required for up to two lesions; at most one non-target lesion can be treated in the same period, and the target lesion can be treated only after the treatment of non-target lesion meets the angiography success criteria and there is no complication. Target and non-target lesions must be located in different major epicardial vessels.
  2. Target lesion meets criteria for revascularization:

    1. ≥ 70% and < 100% diameter stenosis; or
    2. ≥ 50% and < 70% diameter stenosis with clinical evidence of ischemia
  3. Target lesion vessel diameter is between 2.0 mm and 4.0 mm (inclusive), target lesion length ≤ 30 mm.
  4. Clinically judged to be the lesion that requires or is amenable to pretreatment with the study balloon catheter and that the study balloon catheter can pass after pre-dilatation.

General Exclusion Criteria:

  1. Subjects who present with AMI recently (within 7 days).
  2. Subjects who plan to undergo rotational atherectomy, laser coronary atherectomy, cutting balloon during target lesion pretreatment.
  3. Subjects who are scheduled for PCI or CABG within 1 month of the index procedure.
  4. Subjects with history of ischemic stroke or transient ischemic attack within 3 months.
  5. Subjects with bleeding tendency, active gastrointestinal ulcer, history of cerebral hemorrhage or subarachnoid hemorrhage, contraindications to antiplatelet agents and anticoagulant therapy, and inability to receive antithrombotic therapy within 6 months.
  6. Subjects who are scheduled for additional surgical procedures requiring discontinuation of aspirin, clopidogrel within 6 months of the baseline procedure.
  7. Subjects with severe heart failure (NYHA III and above) or left ventricular ejection fraction(LVEF) < 35% (ultrasound or left ventriculography) and/or hemodynamic instability.
  8. Subjects with unstable arrhythmias, such as high-risk premature ventricular contractions, ventricular tachycardia, high-grade atrioventricular block.
  9. Subjects who are unable to receive antiplatelet therapy.
  10. Subjects with hypersensitivity to aspirin, heparin, contrast agent, cobalt-based alloys (including metal elements such as cobalt, chromium, nickel, and tungsten), and polytetrafluoroethylene.
  11. Subjects with renal insufficiency, serum creatinine greater than 177 μmol/L (2.0 mg/dl) or who are receiving hemodialysis.
  12. Subjects who have been diagnosed with the terminal state of acute and chronic diseases such as advanced cancer and have a life expectancy of less than 1 year.
  13. Subjects who have already received or are waiting for organ transplantation.
  14. Subjects with blood routine test showed platelet count less than 50 × 10^9/L or more than 700 × 10^9/L, and/or hemoglobin less than 70 g/L.
  15. Subjects who have participated in other clinical trials of drugs or medical devices before enrollment but have not been to the primary study endpoint until now.
  16. Subjects who are judged by the investigator to be at high clinical risk for the use of the study device, unsuitable or non-compliant, and unable to complete the study as required.
  17. Subjects who are pregnant or breastfeeding (women who may become pregnant must have a pregnancy test within 7 days prior to the baseline procedure).

Angiography Inclusion Criteria:

  1. There are three severe lesions that needs revascularization.
  2. Unprotected left main disease.
  3. Target lesions meeting the following criteria:

    • Acute occlusion or thrombus;
    • Chronic total occlusion;
    • Bifurcation lesion;
    • Within 3 mm of the ostium of the left and right main coronary arteries (LAD/LCX/RCA);
    • CABG bridge stenosis;
    • Involved myocardial bridge;
    • Presence of dissection (Type C and above according to NHLBI classification);
    • Anatomy proximal to or within the target lesion that would preclude delivery of the study balloon catheter (e.g., severe tortuosity, etc.);
    • The study balloon catheter must pass previously implanted stent to reach target lesion.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Non-slip Balloon Catheter
Subjects in experimental arm will be treated with the Non-slip Balloon Catheter manufactured by Shanghai Microport Rhythm Co. Ltd.
The principle of Non-slip Balloon Catheter in dilating stenotic lesions is mechanical extrusion of the vessel through the balloon, resulting in irregular rupture of atheromatous plaque and enlargement of the lumen.
Active Comparator: NSE Coronary Dilatation Catheter
Subjects in control arm will be treated with Lacrosse® NSE manufactured by Goodman Medical Co. Ltd.
The Lacrosse® NSE is an angioplasty catheter with 3 longitudinal elements attached directly proximal and distal to the balloon that produces 3 endovascular surgical incisions during balloon dilation.
Other Names:
  • Lacrosse NSE

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Acute Lumen Gain
Time Frame: Baseline procedure
Acute lumen gain is defined as the difference in the minimum lumen diameter of the target lesion before and after dilatation with the study balloon catheter (Microport or NSE Coronary Dilatation Catheter) as measured by QCA. (Acute lumen gain = minimum lumen diameter measured after dilatation with the study balloon catheter - minimum lumen diameter measured before dilatation with the study balloon catheter, AG=MLD post - MLD pre)
Baseline procedure

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Device success
Time Frame: Baseline procedure
Device success is defined as successful delivery, inflation, deflation, and withdrawal of the study balloon catheter with < 50% diameter stenosis of the lesion after dilatation.
Baseline procedure
Lesion success
Time Frame: Baseline procedure
Lesion success is defined as a target lesion with ≤ 30% residual stenosis and TIMI flow grade of 3 after treatment with any interventional method.
Baseline procedure
Procedural success
Time Frame: During hospitalization (up to 7 days after procedure)
Procedure success is defined as having a target lesion with ≤ 30% diameter residual stenosis and TIMI flow grade of 3 after PCI procedure while the device was successful. There were no deaths, target vessel revascularization, or myocardial infarction during hospitalization (up to 7 days after baseline procedure).
During hospitalization (up to 7 days after procedure)

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Jun Bu, M.D., RenJi Hospital

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

January 3, 2023

Primary Completion (Anticipated)

August 1, 2023

Study Completion (Anticipated)

October 1, 2023

Study Registration Dates

First Submitted

October 31, 2022

First Submitted That Met QC Criteria

November 1, 2022

First Posted (Actual)

November 4, 2022

Study Record Updates

Last Update Posted (Actual)

April 7, 2023

Last Update Submitted That Met QC Criteria

April 5, 2023

Last Verified

April 1, 2023

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Coronary Artery Stenosis

Clinical Trials on Non-slip Balloon Catheter of Shanghai MicroPort Rhythm

3
Subscribe