Kontinuální monitorování glukózy na jednotce intenzivní péče

4. září 2026 aktualizováno: John P Mordes, MD, University of Massachusetts, Worcester

Kontinuální monitorování glukózy na jednotce intenzivní péče: Validace a implementace

The aim of the proposed clinical trial is to study the use of the Dexcom G7 continuous glucose monitor (CGM) within the intensive care unit (ICU) environment. The overall goal is to validate the accuracy and practicality of the Dexcom G7 when used to assess glycemia in critically ill patients.

Přehled studie

Postavení

Dokončeno

Podmínky

Detailní popis

The specific goals are 1) to work with intensive care unit (ICU) staff, in a respiratory ICU setting, to determine how best to place and maintain Dexcom G7 continuous glucose monitors (CGMs) on patients and how to place recording devices and chargers in that environment, 2) download CGM readings to the Dexcom Dashboard in an analyzable format, and 3) to compare simultaneous CGM readings with glucose measurements obtained in the course of routine care as recorded in the electronic medical record. The primary analytical goal is the correlation of CGM glucose measurements with those obtained in the course of routine care. A secondary goal is to determine the frequency of device malfunctions that occur either as a result of device failure (e.g. it falls off) or adverse events (e.g. removal due to skin irritation).

Study subjects will be patients admitted to the 6-ICU UMass Memorial Medical Center (UMMMC) University Campus medical intensive care unit for any reason who have known diabetes or who are hyperglycemic (blood glucose concentration ≥200 mg/dL) with diabetes that was previously undiagnosed or unrecognized. All enrolled volunteers will have a Dexcom G7 CGM place on the skin according to manufacturer's specifications. The devices will remain in place for 10 days or until discharge from the ICU

Typ studie

Intervenční

Zápis (Aktuální)

16

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Massachusetts
      • Worcester, Massachusetts, Spojené státy, 01605
        • UMass Memorial Medical Center

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let a starší (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Popis

Inclusion Criteria:

Campus medical intensive care unit for any reason who have known diabetes or who are hyperglycemic (blood glucose concentration ≥200 mg/dL) with diabetes that was previously undiagnosed or unrecognized.

  • Persons with either type 1 or type 2 diabetes.
  • Persons of either sex.
  • Persons of any age over 18.
  • Persons able to give informed consent or cognitively impaired adults whose legally authorized representative (LAR) can give informed consent.
  • English or Spanish speaking adults.

Exclusion Criteria:

  • Persons unable to provide informed consent.
  • Cognitively impaired persons whose LAR declines to provide informed consent.
  • Patients receiving hydroxyurea, which interferes with sensor function.
  • Patients receiving high dose acetaminophen (> 4 gm/day), which interferes with sensor function.
  • Anasarca affecting preferred areas for device placement (arm, upper buttocks, or thigh), which may interfere with sensor accuracy.
  • Severe cachexia with absence of subcutaneous fat at preferred sensor placement sites, which might interfere with sensor accuracy.
  • Persons who are pregnant.
  • Prisoners.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Jiný
  • Přidělení: N/A
  • Intervenční model: Přiřazení jedné skupiny
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: Single Arm

All members of the arm will have a CGM place and glucose concentration downloaded.

Continuous glucose monitor

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Mean Absolute Relative Difference (MARD).
Časové okno: 6 months

Concordance of glucose concentration results obtained by standard test methods with those obtained nearly simultaneously by a continuous glucose monitoring device was assessed by Mean Absolute Relative Difference (MARD). The MARD is the average percentage difference between the continuous glucose monitor readings measured over 6 months and glucose concentration results obtained by near simultaneous (+/- 5 minutes) standard test methods was used to gauge the accuracy of the CGM in the ICU setting. Typical MARD values reported for CGMs in the outpatient setting average approximately 8%. Typical MARD values reported for CGMs other than the one used in this study n the ICU setting average approximately 12%.

6 months
Clarke Error Grid
Časové okno: 6 months

Concordance of glucose concentration results obtained by standard test methods with those obtained nearly simultaneously by a continuous glucose monitoring device was assessed by Clarke Error Grid. The Clarke Error Grid plots of reference glucose values obtained by point-of-care fingerstick or laboratory determination (x-axis) against CGM values (y-axis). The grid is divided into 5 zones (A-E) that indicate clinical implications of CGM glucose measurements when compared to a "gold standard" Region A: Clinically accurate. Region B: Benign measurement error. Region C: Overcorrection error region CGM values suggest unnecessary treatment. Region D: Serious hypo- or hyperglycemia detection error region. Region E: Erroneous treatment region. CGM fails to detect potentially dangerous hypo- or hyperglycemia Ideally, all values are in Regions A and B. We report the percentage of correlated values that fall in each region.

6 months

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Unplanned Event Frequency
Časové okno: 6 months

Number of occurrences per patient of device failure or or unforeseen device removal

6 months

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: John P Mordes, MD, UMass Chan Medical School

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

20. února 2024

Primární dokončení (Aktuální)

25. července 2025

Dokončení studie (Aktuální)

25. července 2025

Termíny zápisu do studia

První předloženo

7. prosince 2023

První předloženo, které splnilo kritéria kontroly kvality

19. prosince 2023

První zveřejněno (Aktuální)

5. ledna 2024

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

29. září 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

4. září 2026

Naposledy ověřeno

1. září 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

ANO

Popis plánu IPD

Study design and deidentified aggregate glucose concentration data will be shared. No individual patient data will be shared.

Časový rámec sdílení IPD

One year

Kritéria přístupu pro sdílení IPD

Publication

Typ podpůrných informací pro sdílení IPD

  • PROTOKOL STUDY
  • MÍZA
  • ICF

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ano

produkt vyrobený a vyvážený z USA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .