Viabilidad de usar NeoSpot en la configuración de la comunidad
Viabilidad de la evaluación de los signos vitales por parte de los trabajadores de salud comunitarios durante la extensión comunitaria de atención prenatal
Continuous vital sign monitoring is a basic tenet of specialized care in the developed world that is vastly underutilized during hospital or clinic admissions or outpatient routine visits in most low-and-middle income countries (LMICs). Despite the positive outcomes associated with vital sign monitoring (i.e., increased survival-to-discharge rates, lower complication rates and shorter length of stay in hospital), the prohibitive costs of conventional patient monitors and the difficulty in maintaining complex medical equipment limit its practice in the developing world.
Currently, due to lack of medical supplies, most ANC clinics - within the health facilities or during outreach activities - do not monitor for vital signs and blood pressure among pregnant women. While many devices exist, their ease of use and high-cost, including maintenance costs, hinder screening and monitoring programs in low resource settings. Accurate and low-cost vital sign monitoring devices are required to improve identification and treatment of women with danger signs during their routine ANC visits. To meet the growing demand for vital sign monitors during the COVID-19 pandemic, Neopenda has adapted an affordable, wearable, wireless vital sign monitoring solution (neoSpotTM), that measures temperature, respiration rate, blood oxygen saturation, pulse rate, and blood pressure.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Continuous vital sign monitoring is a basic tenet of specialized care in the developed world that is vastly underutilized during hospital or clinic admissions or outpatient routine visits in most low-and-middle income countries (LMICs). Despite the positive outcomes associated with vital sign monitoring (i.e., increased survival-to-discharge rates, lower complication rates and shorter length of stay in hospital),1 the prohibitive costs of conventional patient monitors and the difficulty in maintaining complex medical equipment limit its practice in the developing world.
Wearable health devices (WHDs) are increasingly helping people better monitor their health status both at an activity/fitness level for self-health tracking and at a medical level providing more data to healthcare providers to increase the potential for early diagnosis and guidance of treatment. Key advancements in technology are enabling the creation of smaller computers than ever before; allowing wearable technology to incorporate miniaturized systems to enhance the quality and convenience of patient care.1 Advances in materials science, chemical analysis techniques, equipment design and manufacturing methods have further laid the foundation for the continuous evolution of wearable systems over the years.2
WHDs when properly designed, implemented and adopted can provide ample benefits for healthcare providers and patients. Wearable technologies like Apple watch, Fitbit, Jawbone, ViSi Mobile and Vital Connect wireless patch have been used in tracking personal physiological and biological parameters for routine activity performance and/or clinical monitoring.3,4 These devices collect data such as heart rate, stress levels, obesity, oxygen saturation, blood pressure and calories; and serve a broad range of use cases from newborn to elderly patients in different settings such as hospitals, nursing homes and homecare settings.
Measurement of vital signs in both in- and out-patient departments and during community outreach activities is necessary to assess the clinical situation of the patient and capture early warning scores for deterioration. The currently practice in most LMICs is for a clinician to take routine vital sign measurements intermittently and manually record these on a clinical chart. However, this leaves a lot of room for missed detection of early warning scores. Delays in diagnosing clinical deterioration prevent clinicians from taking corrective actions and are associated with increased complication rates and mortality. The use of wearable devices for long term monitoring is intended to provide instant diagnosis of acute events that will in turn lead to more effective and timely treatment of patients.5 Furthermore, the situation becomes more dire during community outreach activities (i.e., child health week, community ANC outreach, etc.), which are usually conducted by limited clinicians and several community health workers (CHWs).
In contrast to the traditional monitoring devices that have been in use in clinical settings, WHDs may be more suited to the constraints of low-resources settings. Conventional medical equipment frequently fail in health facilities in LMICs due to complex design and specifications, and environmental constraints including power instability, internet access, space limitations and availability of spare parts. This calls upon the need for more feasible innovations to improve on the quality of care for people living in LMICs. WHDs offer a promising solution.
Currently, due to lack of medical supplies, most ANC clinics - within the health facilities or during outreach activities - do not monitor for vital signs and blood pressure among pregnant women. While many devices exist, their ease of use and high-cost, including maintenance costs, hinder screening and monitoring programs in low resource settings. Accurate and low-cost vital sign monitoring devices are required to improve identification and treatment of women with danger signs during their routine ANC visits. To meet the growing demand for vital sign monitors during the COVID-19 pandemic, Neopenda has adapted an affordable, wearable, wireless vital sign monitoring solution (neoSpotTM), that measures temperature, respiration rate, blood oxygen saturation, pulse rate, and blood pressure.
Tipo de estudio
Inscripción (Actual)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Lusaka Province
-
Lusaka, Lusaka Province, Zambia, 10101
- Kanyama First Level Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Pregnant women residing at Kanyama compound and attending ANC care during routine community outreach activities will be approached, screened, and consented for study participation.
Community Health Workers who have used the device on enrolled study participants (pregnant women) will under-go in-depth interviews.
Descripción
Pregnant women:
Inclusion criteria
- Pregnant
- 18+ years of age
- Willing to consent
Exclusion criteria
- Unable to consent
- Not pregnant
- Age below 18 years
In-depth Interviews:
- Community Health Workers who have used the NeoSpot device
- Pregnant women who have experienced the device and enrolled in the study
2. 18+ years of age 3. Willing to consent
Exclusion criteria
- Pregnant women not enrolled in the study
- Unable to consent
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: CASE_ONLY
- Perspectivas temporales: CROSS_SECTIONAL
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
Pregnant women
Pregnant women attending antenatal care clinic during routine community outreach activities in Lusaka, Zambia. |
Pregnant women will undergo screening of their vital signs using the NeoSpot device.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Feasibility of using a wearable, wireless vital sign monitoring solution NeoSpot device by Community Health Workers (CHWs)
Periodo de tiempo: Baseline to day 1
|
To describe the feasibility of CHWs to use the NeoSpot device during community ANC outreach through in-depth interviews |
Baseline to day 1
|
|
Acceptability of using a wearable, wireless vital sign monitoring solution NeoSpot device by Community Health Workers (CHWs)
Periodo de tiempo: Baseline to day 1
|
To describe the acceptability of CHWs to use the NeoSpot device during community ANC outreach through in-depth interviews |
Baseline to day 1
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Acceptability of using a wearable, wireless vital sign monitoring solution NeoSpot device by pregnant women
Periodo de tiempo: Baseline to day 1
|
To describe the acceptability of pregnant women to be screened using the NeoSpot device during community ANC outreach through in-depth interviews |
Baseline to day 1
|
|
Collect photoplethysmograph (PPG) data using a wearable, wireless vital sign monitoring solution NeoSpot device
Periodo de tiempo: Baseline to day 1
|
To obtain raw PPG data from the prototype NeoSpot device which will be used in the development of an accurate and reliable blood pressure algorithm. |
Baseline to day 1
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Albert Manasyan, MD, Center for Infectious Disease Research in Zambia (CIDRZ)
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- NeoSpot 3109-2022
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Descripción del plan IPD
De-identified study data will be available to other researchers upon reasonable request to the study PI.
Marco de tiempo para compartir IPD
Following study closure and publication of the main study findings.
Criterios de acceso compartido de IPD
De-identified study data will be available to other researchers upon reasonable request to the study PI.
Tipo de información de apoyo para compartir IPD
- SAVIA
- CIF
- CÓDIGO_ANALÍTICO
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .