Time Course Evolution of Cardiac Output (TCCO)
Time Course Evolution of Cardiac Output in Critically Ill Patients After a Fluid Expansion
Fluid expansion is the first therapeutic option in patients presenting acute circulatory failure but the duration of its hemodynamic effects (persistency and time of maximal increase in cardiac output) is unknown.
This study is seeking to describe in critically ill patients, the time course evolution of cardiac output over a 2-hours period after a fluid expansion.
The objectives are:
- to identify patterns of fluid responsiveness
- to determine the time when the maximal increase in cardiac output occurs during and a after fluid expansion
- to compare patients' characteristics between patterns
Patients with acute circulatory failure will be recruited as soon as a fluid expansion will be decided by the physician in charge and the effects of fluid expansion on hemodynamic indices (cardiac output, arterial pressure) will be continuously recorded through a transpulmonary thermodilution device over a 2-hours period.
No changes in ventilatory settings nor vasopressors or sedatives will be allowed during the study.
Patients will be categorized into patterns according to the changes in cardiac output after fluid expansion and their characteristics will be compared.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
The study will be conducted in four medico-surgical ICUs in France between April 2016 and April 2018.
Since fluid challenge and invasive monitoring by thermodilution device is standard of care for septic shock management, the institutional review board waived patient consent. All patients and/or their next of kind will receive written information.
Eligible patients will have to present an acute circulatory failure for whom the physician in charge will decide to start a fluid expansion.
Hemodynamic variables will be obtained through transpulmonary thermodilution and pulse contour analysis (PICCO2 device, Pulsion Germany).
Fluid expansion will consist in the infusion of 500 ml of saline through a central venous catheter in a standardized 10-minutes period. The duration of infusion will be controlled by an airbag pressurized at 300 mmHg.
Fluid responsiveness will be defined by an increase in cardiac output over 15-per-cent from baseline (before fluid expansion).
Study design:
At time of decision to make the fluid expansion, a calibration of the PICCO2 device will be performed and a first set of hemodynamic measurements will be collected (cardiac output, cardiac function index, extravascular lung water, permeability vascular pulmonary index, global end diastolic volume, arterial pressure, heart rate).
Then, fluid expansion will be administrated in less than 10 minutes. From the start of fluid expansion to the end of the two-hours period ot time, pulse contour cardiac output and arterial pressure will be continuously recorded.
During the whole two hours period, no change in vasopressor dosage nor mechanical ventilation settings will be allowed.
In case of hemodynamic instability, defined by a mean arterial pressure under 65mmHg, a new fluid expansion could be realized. In this last case, the protocol will start again from the beginning.
Tipo di studio
Iscrizione (Effettivo)
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- acute circulatory failure (infusion of norepinephrine)
- invasive mechanical ventilation through an endotracheal tube
- decision of fluid expansion
Non inclusion Criteria:
- extracorporeal membranous oxygenation (ECMO)
- active bleeding
- continuous renal replacement therapy with weight loss
- administration of diuretics within the past six hours
- decision of therapeutic limitation,
- age under eighteen years
Exclusion criteria:
- hemodynamic instability after fluid expansion (mean arterial pressure < 65mmHg)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: Coorte
- Prospettive temporali: Prospettiva
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
---|---|
Patients
The patients will receive a 500 ml fluid expansion over a standardized 10 minutes period
|
The fluid expansion will consist in a less than 10 min infusion of 500 milliliters of saline through a central venous catheter (jugular).
The duration of infusion will be controlled by an airbag pressurized at 300 mmHg.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
---|---|---|
Change in cardiac output during fluid expansion
Lasso di tempo: 10 minutes
|
Difference between maximal cardiac output during fluid expansion and baseline
|
10 minutes
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
---|---|---|
Change in cardiac output after fluid expansion
Lasso di tempo: 2 hours
|
Change in cardiac output after fluid expansion
|
2 hours
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Martin Dres, MD, PhD, APHP
Pubblicazioni e link utili
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- ADOREPS
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Insufficienza circolatoria acuta
-
Region of Southern DenmarkOdense Municipality, Denmark; Kerteminde Municipality, Denmark; Svendborg Municipality...Completato
-
Peking University Third HospitalShanghai Jiao Tong University School of MedicineAttivo, non reclutante
-
University of Southern DenmarkCompletatoCondizioni mediche acuteDanimarca
-
AstraZenecaCompletatoRiacutizzazioni acute della BPCOCina
-
Assiut UniversityCompletato
-
Central Hospital, Nancy, FranceSconosciutoCondizioni acute in terapia intensivaFrancia
-
Centre Hospitalier Universitaire de NiceCompletato
-
GlaxoSmithKlineCompletato
-
Vanderbilt UniversityTerminatoLesioni polmonari, acuteStati Uniti
-
Children's Hospital of PhiladelphiaNational Heart, Lung, and Blood Institute (NHLBI)CompletatoLesioni polmonari acute pediatricheStati Uniti