A Novel Method to Assess the Cornea Biomechanical Properties With Schiotz Tonometer
A Novel Method to Assess the Cornea Biomechanical Properties With Schiotz
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Zhiwei Li, MD.
- Phone Number: +86-18053106729
- Email: zhiweiovs@hotmail.com
Study Locations
-
-
Shandong
-
Jinan, Shandong, China
- Recruiting
- Shandong Provincial Hospital
-
Contact:
- Lihua Wang, MD
- Email: wang_glasses@163.com
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- People without the disease mentioned in exclusion criteria part.
Exclusion Criteria:
- Patients with ocular diseases including keratitis, conjunctivitis, history of chronic eye/systemic diseases except myopia and keratoconus, history of ocular surgery except LASIK, pregnant or lactating females.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Control
People without keratoconus, history of ocular surgery, and other diseases mentioned in exclusion criteria.
Normal people will receive treatment or measurement including: Schiotz tonometer measurement, UVA/riboflavin corneal crosslinking, Keratoplasty, Ocular morphology measurement,and routine ophthalmic examination.
|
The corneal biomechanical properties will be measured using a Schiotz tonometer with routine manipulation protocol.This measurement will be used in normal people, keratoconic patients, patients received keratoplasty.
The UVA/riboflavin corneal crosslinking will be applied using a UV-X lamp (Peschke Meditrade GmbH, Switzerland) with routine manipulation protocol (3mW/cm2, 365nm, 30 minutes).This treatment will be used in keratoconic patients.
The keratoplasty mainly include femto-LASIK (Laser in situ keratomileusis), which will be applied using a Wavelight FS200 and Wavelight EX500 Excimer Laser (Alcon Inc.
USA.).The keratoplasty will be applied in patients who would like to receive the surgery.
Cornea thickness will be measured with a pachymeter (Tomey SP-100 Pchymeter, Japan); cornea topography will be measured with Topolyzer Vario (Allegro, Wavelight GmBH, Germany); anterior chamber depth, white to white, and ocular axis length will be measured using a IOL master (Carl Zeiss Meditec, Germany).
These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.
Vision acuity will be measured with a decimal visual chart; IOP (Intra-ocular pressure) will be measured with a tonometer (Topcon CT-80, Topcon, Japan) , fundoscopy examination will be apllied with a direct ophthalmoscopy, slit lamp examination will be applied with a slit lamp.
These examinations will be used in normal people, keratoconic patients, patients received keratoplasty.
Cornea biomechanical properties will be measured with a ocular response analyzer (Reichert, USA.) and/or a Corvis-ST (Oculus, Germany).These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.
|
|
Experimental: Keratoconic patients
Patients with keratoconus.Keratoconic patients will receive treatment or measurement including:Schiotz tonometer measurement, UVA/riboflavin corneal crosslinking,Ocular morphology measurement,and routine ophthalmic examination.
|
The corneal biomechanical properties will be measured using a Schiotz tonometer with routine manipulation protocol.This measurement will be used in normal people, keratoconic patients, patients received keratoplasty.
The UVA/riboflavin corneal crosslinking will be applied using a UV-X lamp (Peschke Meditrade GmbH, Switzerland) with routine manipulation protocol (3mW/cm2, 365nm, 30 minutes).This treatment will be used in keratoconic patients.
Cornea thickness will be measured with a pachymeter (Tomey SP-100 Pchymeter, Japan); cornea topography will be measured with Topolyzer Vario (Allegro, Wavelight GmBH, Germany); anterior chamber depth, white to white, and ocular axis length will be measured using a IOL master (Carl Zeiss Meditec, Germany).
These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.
Vision acuity will be measured with a decimal visual chart; IOP (Intra-ocular pressure) will be measured with a tonometer (Topcon CT-80, Topcon, Japan) , fundoscopy examination will be apllied with a direct ophthalmoscopy, slit lamp examination will be applied with a slit lamp.
These examinations will be used in normal people, keratoconic patients, patients received keratoplasty.
Cornea biomechanical properties will be measured with a ocular response analyzer (Reichert, USA.) and/or a Corvis-ST (Oculus, Germany).These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.
|
|
Experimental: Patients received keratoplasty
Patients received keratoplasty.
Patients received keratoplasty will receive treatment or measurement including:Schiotz tonometer measurement,Keratoplasty, Ocular morphology measurement,and routine ophthalmic examination..
|
The corneal biomechanical properties will be measured using a Schiotz tonometer with routine manipulation protocol.This measurement will be used in normal people, keratoconic patients, patients received keratoplasty.
The keratoplasty mainly include femto-LASIK (Laser in situ keratomileusis), which will be applied using a Wavelight FS200 and Wavelight EX500 Excimer Laser (Alcon Inc.
USA.).The keratoplasty will be applied in patients who would like to receive the surgery.
Cornea thickness will be measured with a pachymeter (Tomey SP-100 Pchymeter, Japan); cornea topography will be measured with Topolyzer Vario (Allegro, Wavelight GmBH, Germany); anterior chamber depth, white to white, and ocular axis length will be measured using a IOL master (Carl Zeiss Meditec, Germany).
These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.
Vision acuity will be measured with a decimal visual chart; IOP (Intra-ocular pressure) will be measured with a tonometer (Topcon CT-80, Topcon, Japan) , fundoscopy examination will be apllied with a direct ophthalmoscopy, slit lamp examination will be applied with a slit lamp.
These examinations will be used in normal people, keratoconic patients, patients received keratoplasty.
Cornea biomechanical properties will be measured with a ocular response analyzer (Reichert, USA.) and/or a Corvis-ST (Oculus, Germany).These measurements will be used in normal people, keratoconic patients, patients received keratoplasty.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The Mulee factor obtained with Schiotz tonometer as a measure of cornea biomechanical property
Time Frame: up to 1 year
|
Mulee factor= Value displayed with Schiotz tonometer under 7.5g load-Value displayed with Schiotz tonometer under 5.5g load
|
up to 1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Guoying Mu, MD., Shandong Provincial Hospital
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- No.018
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Keratoconus
-
NCT04598932Enrolling by invitationKeratoconus | Keratoconus, Unstable | Keratoconus, Stable
-
NCT06152484RecruitingScansys, Pentacam, Keratoconus, Subclinical Keratoconus
-
NCT04594512Active, not recruitingKeratoconus | Keratoconus of Right Eye | Keratoconus, Unstable, Right Eye
-
NCT05717673Recruiting
-
NCT04731727Not yet recruitingKeratoconus, Unstable
-
NCT04045626Unknown
-
NCT02883868CompletedProgressive Keratoconus
-
NCT05314738RecruitingProgressive Keratoconus
-
NCT05220904Active, not recruitingKeratoconus, Stable
Clinical Trials on Schiotz tonometer
-
NCT02697825UnknownIntraocular Pressure | Optic Nerve Sheath Diameter
-
NCT00570791CompletedIntraocular Pressure
-
NCT04180111Unknown
-
NCT00409669UnknownElevated Intraocular Pressure