Synthetic Mesh Materials In Sling Surgery

Use Of Three Types Of Synthetic Mesh Materials In Sling Surgery: A Prospective Randomized Clinical Trial Evaluating Effectiveness And Complications

The purpose of this study is to determine the clinical results contributions to surgical success,and complications of mixed type of mesh materials as well as prolen mesh materials in sling surgery in a 3 year follow-up the first time in literature.

Study Overview

Status

Completed

Conditions

Intervention / Treatment

Detailed Description

Broad based double forced sling operations were performed in 144 patients by using 3 different types of mesh materials between 2004 and 2007. Group I consisted of 48 patients in whom Vypromesh® (Ethicon,USA) was used; Group II consisted of 48 patients in whom Ultrapromesh®( Ethicon,USA) and Group III consisted of 48 patients in whom Prolene light mesh® (Johnson&Johnson,USA) was used. The data of the patients and the success of the operation were evaluated based on 24hr pad test, ICIQ-SF scoring, and Korman questionnaire analysis.

Main outcome measures:The Ultrapromesh® synthetic sling procedures have lower complications incidence and higher success rates than the other synthetic slings in 3-year follow-up.

Study Type

Interventional

Enrollment (Actual)

144

Phase

  • Not Applicable

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

31 years to 75 years (Adult, Older Adult)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

Female

Description

Inclusion Criteria:

  • Stress urinary incontinence
  • Mix urinary incontinence
  • Previous failed anti-incontinence surgery
  • Previous gynecologic surgery

Exclusion Criteria:

  • Urodynamical detrusor overactivity or impaired bladder activity
  • Prolaps of pelvic organ
  • Urge incontinence
  • Neurogenic bladder
  • Bladder outlet obstruction
  • Urinary fistula, Pregnancy
  • Active urinary or vaginal enfection
  • Contraindication to anesthesia
  • > 100ml PVR urine volume

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Vypromesh®(Ethicon,USA)
Vypromesh®(semiabsorbable multiflament mesh;non-absorbable Polypropylene+absorbable Poliglactin)
An incision of inverted A shape was inflicted on the anterior vaginal wall(AVW)of the vagina.The upper part of A shaped incision was formed into an island belonging to the vaginal wall.This patch was 3×4cm in most of the patients.Proximal AVWwas dissected as a flap.Synthetics mesh materials were first sutured onto the upper part of the A on the vaginal island with absorbable vicrly sutures.Then,with 2polypropilen sutures,these meshes were fixed on both the right and left sides of this island in a helical manner to form a suspension and using curved Kishner needles,the prolene sutures were transferred to suprapubic area.These sutures were ligated on the rectus fascia in a crosswise manner.The mobile lower wing was advanced onto the island and was sutured onto the vaginal skin with intermittent sutures using 3-0 monocryl sutures.After cystoscopy,the prolene sutures were ligated crosswise in the suprapubic region.Special attention was paid notto create much tension on the mesh material.
Active Comparator: Ultrapromesh®(Ethicon,USA)
Ultrapromesh®(semiabsorbable monofilament mesh;non-absorbable Polypropylene+absorbable polyglecaprone).
An incision of inverted A shape was inflicted on the anterior vaginal wall(AVW)of the vagina.The upper part of A shaped incision was formed into an island belonging to the vaginal wall.This patch was 3×4cm in most of the patients.Proximal AVWwas dissected as a flap.Synthetics mesh materials were first sutured onto the upper part of the A on the vaginal island with absorbable vicrly sutures.Then,with 2polypropilen sutures,these meshes were fixed on both the right and left sides of this island in a helical manner to form a suspension and using curved Kishner needles,the prolene sutures were transferred to suprapubic area.These sutures were ligated on the rectus fascia in a crosswise manner.The mobile lower wing was advanced onto the island and was sutured onto the vaginal skin with intermittent sutures using 3-0 monocryl sutures.After cystoscopy,the prolene sutures were ligated crosswise in the suprapubic region.Special attention was paid notto create much tension on the mesh material.
Active Comparator: Prolene light mesh®(Johnson&Johnson,USA)
Prolene light mesh®(cpp-Condensed monofilament non absorbable polypropylene mesh)
An incision of inverted A shape was inflicted on the anterior vaginal wall(AVW)of the vagina.The upper part of A shaped incision was formed into an island belonging to the vaginal wall.This patch was 3×4cm in most of the patients.Proximal AVWwas dissected as a flap.Synthetics mesh materials were first sutured onto the upper part of the A on the vaginal island with absorbable vicrly sutures.Then,with 2polypropilen sutures,these meshes were fixed on both the right and left sides of this island in a helical manner to form a suspension and using curved Kishner needles,the prolene sutures were transferred to suprapubic area.These sutures were ligated on the rectus fascia in a crosswise manner.The mobile lower wing was advanced onto the island and was sutured onto the vaginal skin with intermittent sutures using 3-0 monocryl sutures.After cystoscopy,the prolene sutures were ligated crosswise in the suprapubic region.Special attention was paid notto create much tension on the mesh material.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
continence rates at three years after surgery
Time Frame: three years after surgery
Ultrapromesh® with its superior biomechanical characteristics and with its high success rates,low vaginal and urethral extrusion and denovo urgency rates determined in clinical studies,can be reliably and effectively used in sling surgery.
three years after surgery

Secondary Outcome Measures

Outcome Measure
Time Frame
urethral erosion at three years after surgery
Time Frame: three years after surgery
three years after surgery
vaginal erosion at three years after surgery
Time Frame: three years after surgery
three years after surgery
Denovo urgency at three years after surgery
Time Frame: three years after surgery
three years after surgery
urine retantion at three years after surgery
Time Frame: three years after surgery
three years after surgery
sutur granuloma at three years after surgery
Time Frame: three years after surgery
three years after surgery

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

July 1, 2004

Primary Completion (Actual)

July 1, 2007

Study Completion (Actual)

November 1, 2010

Study Registration Dates

First Submitted

April 28, 2011

First Submitted That Met QC Criteria

May 4, 2011

First Posted (Estimate)

May 5, 2011

Study Record Updates

Last Update Posted (Estimate)

May 5, 2011

Last Update Submitted That Met QC Criteria

May 4, 2011

Last Verified

July 1, 2004

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Incontinence

Clinical Trials on Synthetic sling surgery

3