- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT02765360
EIT Study With COPD and OHS Patients (EIT Step 2) (EIT & NIV Step)
Changes in Lung Ventilation With Different Modes of Non-invasive Ventilation in COPD and OHS Patients
Patients with severe respiratory diseases such as chronic obstructive pulmonary disease (COPD) or obesity-hypoventilation syndrome (OHS) can benefit from having non-invasive ventilation (NIV). NIV consists of a machine (ventilator) that is blowing air inside a patient's airway through a mask. NIV provides patients with a bigger breath. Bigger breaths help patients to have a more oxygen and less waste gas (or carbon dioxide) in their body.
These changes can improve outcomes and quality of life. In order to provide appropriate ventilation for each patient, the ventilator can generate different types of blowing:
- Continuous positive airway pressure (CPAP) which delivers a constant flow of air through the mask
- Pressure support ventilation (PSV) which delivers a constant flow of air through the mask and, on top of that, delivers more flow when the patient begins to inhale
- Volume targeted ventilation which delivers a flow of air through the mask that is adjusted breath by breath in order to achieve a preset volume.
These different type of blowing have consequences on patient comfort as well as on the improvement of their ventilation.
To assess the improvement of the ventilation, currently blood tests are used, however, these reflect overall output and may miss more subtle changes in breathing that could affect how patients feel.
Electrical impedance tomography (EIT) is a new technology that involves wearing a belt of sensors around the chest that provides information on how well the lungs are being filled with air by the ventilator. It allows a non-invasive assessment of the effect of NIV on lung ventilation in real-time.
The investigators hope to use the EIT technology to assess in real-time patients lung ventilation when they are using the NIV. The investigators hope that EIT will provide information on which type of blowing is more effective and more comfortable than the others.
Study Overview
Detailed Description
Chronic lung disease can sometimes progress to the extent that patients can no longer clear the waste gas from their blood. Treatment can be offered with a mask and machine (ventilator) that helps people breathe and aims to improve their lung condition. It is common for people's lungs to be affected variably, i.e. left more than right or top of lung more than bases of lungs. The way in which the ventilator is set may affect how well the machine deals with these differences. If the lung is better ventilator patients may find the machine more comfortable and it may be more effective.
Electrical impedance tomography (EIT) is a new technology that involves wearing a belt of sensors around the chest that provides information on how well the lungs are being filled with air by the ventilator. It allows the assessment of these differences, which previously required the use of invasive equipment to obtain.
Optimising ventilator settings in the administration of non-invasive ventilation (NIV) can be improved with the addition of individual physiological data. This approach is limited due to the invasive techniques required to obtain this information, often leading to less ideal NIV settings promoting patient-ventilator asynchrony. It has been recently demonstrated by our group that all patients established on domiciliary NIV have a degree of patient-ventilator asynchrony and that the commonest type of asynchrony are triggering issues. Triggering asynchrony is promoted by mismatch between a patient's intrinsic positive end-expiratory pressure (iPEEP) and applied expiratory positive airway pressure (EPAP) with these ineffective efforts contributing to an increased work of breathing and patient discomfort. Previous strategies used to optimise patient triggering have involved the placement of oesophageal catheters in order to measure neural respiratory drive (NRD) to the diaphragm by electromyography (EMG) but again this process is invasive and often poorly tolerated. Electrical Impedance Tomography (EIT) is a non-invasive, bedside monitoring technique that provides semi-continuous, real-time information about the regional distribution of the changes in electrical resistivity of the lung tissue due to variations in ventilation in relation to a reference state.
Information is gained by repeatedly injecting small alternating electric currents (usually 5 mA) at high frequency of 50 - 80 kHz through a system of skin electrodes (usually 16) applied circumferentially around the thorax in a single plane between the 4th and 6th intercostal space. While an adjacent pair of electrodes 'injects' the current ('adjacent drive configuration'), all the remaining adjacent passive electrode pairs measure the differences in electric potential. A resistivity (impedance) image is reconstructed from this data by a mathematical algorithm using a two dimensional model and a simplified shape to represent the thoracic cross-section.
The resulting image possesses a high temporal and functional resolution making it possible to monitor dynamic physiological phenomena (e.g. delay in regional inflation or recruitment) on a breath by breath basis. It is important to realize that the EIT images are based on image reconstruction techniques that require at least one measurement on a well-defined reference state. All quantitative data are related to this reference and can only indirectly quantify (relative) changes in local lung impedance (but not absolute).
EIT can be used in mechanically ventilated patients to assess recruitment and to optimise ventilator settings to reduce risk of iatrogenic ventilator associated lung injury.
In the supine posture obese patients can generate significant levels of iPEEP that contribute to increased levels of neural respiratory drive compared with the upright posture. There has been much debate regarding the optimal ventilator strategy in patients with obesity related respiratory failure, with uncontrolled trial data to support simple continuous positive airway pressure, pressure support (PSV) NIV and volume targeted (VT) NIV. There has been no robust evidence to suggest superiority of a single mode but post hoc data suggests superior control of sleep disordered breathing in patients in pressure controlled mode. It is unclear whether the extended inspiratory time of pressure controlled mode is allowing superior gas exchange by maintaining airway distension and preventing regional collapse.
In COPD, patients' response to treatment can be influenced by disease heterogeneity with some patients showing even distribution of lung damage and others marked differences throughout the lungs. This variation can lead to significant differences in the lung mechanics in different regions with optimal NIV settings for some regions having potentially deleterious effects on neighbouring zones. It has been shown that control of hypoventilation and improved blood gas exchange is essential in order to improve outcomes with NIV in COPD but is less clear if pressure control ventilation as advocated by Windisch and colleagues is required in order to achieve this effect. Inappropriate settings of NIV can also lead to dynamic distension that results in a decrease of tidal volume and an increase in patient discomfort.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
London, United Kingdom, SE1 7EH
- Guys and St Thomas NHS Trust
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- On domiciliary NIV for at least 3 months
- Domiciliary NIV set up following an arterial puncture showing a PaCO2 > 6 kPa
- Compliance of > 4 hours per night
- FEV1 / FVC < 70% and FEV1 < 70% for COPD participants
- FEV1 > 70% for OHS participants
- Previous chest computed tomography for COPD participants
- BMI >35 kg/m2 for OHS participants
Exclusion Criteria:
- Pregnancy
- Aged <18, >80
- Significant physical or psychiatric comorbidity that would prevent compliance with trial protocol
- Decompensated respiratory failure (pH < 7.35)
- BMI > 50kg/m2
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
---|---|
Experimental: Treatment
Each patient will be assigned to Continuous Positive Airway Pressure (CPAP), Pressure Support Ventilation (PSV) and Pressure Control Ventilation (PCV) modes in a random order with a 10 minute washout period modes.
|
Participants will be established on the randomised mode of ventilation and will have continuous assessment of the following during the assessment period:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Characteristics seen during ventilation in different modes of ventilation
Time Frame: 1 day
|
What happens to the lung when ventilation on different modes
|
1 day
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Lung volumes on EIT compared with pneumotachography assessed lung volumes
Time Frame: 1 day
|
Comparing lung volumes comparison whilst on EIT and pneumotachography
|
1 day
|
Patient ventilator asynchrony
Time Frame: 1 day
|
1 day
|
|
Neural respiratory drive (EMGpara)
Time Frame: 1 day
|
1 day
|
|
Subjective patient comfort (Visual analogue scale - VAS - Borg scale)
Time Frame: 1 day
|
1 day
|
|
Patient comfort and lung homogeneity
Time Frame: 1 day
|
Assessment of patient comfort during ventilation
|
1 day
|
Collaborators and Investigators
Collaborators
Investigators
- Study Chair: Nick Hart, Guys and St Thomas' NHS Foundation Trust
Study record dates
Study Major Dates
Study Start
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimate)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on COPD
-
University Medical Center GroningenCompleted
-
Peking University First HospitalFirst Affiliated Hospital Xi'an Jiaotong University; Shandong Provincial Hospital and other collaboratorsRecruiting
-
Hôpital NOVORecruiting
-
Rigshospitalet, DenmarkRecruiting
-
NHS Greater Glasgow and ClydeLenus Health; University of Glasgow Robertson Centre for Bio StatisticsRecruiting
-
Xemed LLCUniversity of Pennsylvania; Temple UniversityNot yet recruiting
-
Erasme University HospitalRecruiting
-
Istituti Clinici Scientifici Maugeri SpARecruiting
-
Temple UniversityGlaxoSmithKlineNot yet recruiting
Clinical Trials on Treatment Group
-
The Affiliated Hospital of Xuzhou Medical UniversityUnknownChronic Kidney Diseases | Mesenchymal Stem Cells | Renal Interstitial FibrosisChina
-
University of California, San DiegoNational Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)Completed
-
Tasly Pharmaceutical Group Co., LtdCompleted
-
Baylor College of MedicineCompletedAttention Deficit and Disruptive Behavior Disorders | Attention Deficit Hyperactivity DisorderUnited States
-
Università degli Studi di FerraraCompleted
-
New Mexico VA Healthcare SystemCompletedPost Traumatic Stress DisorderUnited States
-
University Hospital Inselspital, BerneCompletedMultiple SclerosisSwitzerland
-
University of Erlangen-NürnbergFa. Reck MOTOmedCompleted
-
University of MinnesotaCompleted
-
Beijing HuiLongGuan HospitalCompleted