- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT06007339
PerQseal® Elite Venous Clinical Study (ELITE-Venous) (ELITE-Venous)
Safety and Performance Study for Venous Large Hole Vascular Closure Device - ELITE Study
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
This study is a prospective, multicentre, single-arm study to investigate the safety and efficacy of the PerQseal Elite in up to 97 patients at up to 12 European investigational sites. The study shall not be blinded prior to, during or post the procedure. Patients undergoing a percutaneous catheter-based venous interventional procedure (e.g., mitral valve repair, leadless pacemaker implantation, circulatory assist or ECMO via large bore femoral vein catheter) requiring a venotomy created by 14 to 22F sheaths (venotomies up to 26F), via the common femoral vein will be screened against the study inclusion/exclusion criteria.
All subjects shall have a 30-minute, 60-minute, pre-discharge (~48 hours), 30-Days ± 7-Days and 180-Days ± 30-Days follow-up assessments.
All safety data from the study will be assessed by the Data Safety Monitoring Committee on a continuous basis.
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: Chris Martin
- Phone Number: +353 91 395 442
- Email: Chris.Martin@vsuremed.com
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age ≥ 19 years.
- Clinically indicated for a percutaneous venous interventional catheter-based procedure, e.g., mitral valve edge to edge repair, left atrial appendage device closure, leadless pacemaker implantation, patent foramen ovale closure or use of a circulatory assist device or extracorporeal oxygenation using a common femoral venotomy created by a 14 to 22F sheath (venotomy up to 26F).
- Subject is willing and able to provide appropriate study-specific informed consent, follow protocol procedures, and comply with follow-up visit requirements.
- Females who are not pregnant or lactating and not planning to become pregnant for the duration of the study.
Baseline Exclusion Criteria:
- Evidence of current systemic bacterial or cutaneous infection, including groin infection,
- Known bleeding diathesis, unstable INR, definite or potential coagulopathy, platelet count < 100,000/μl or subjects on long term anticoagulants with an INR > 2.2 within 12 hours prior to index procedure,
- Significant anaemia (example: haemoglobin < 8 g/dL or haematocrit < 22%), within 24 hours prior to index procedure,
- Known type II heparin-induced thrombocytopenia,
- Documented right ventricular dysfunction < 13%,
- Ipsilateral or contralateral lower extremity amputation,
- Previous groin surgery within the region of the ipsilateral vessel access,
- Common femoral vein diameter stenosis > 50% or previous bypass surgery/stent placement in the common femoral vein of target leg,
- Known existing nerve damage in the target leg,
- Nephrotic syndrome or renal insufficiency (Glomerular Filtration Rate ≤ 30 ml/min or baseline serum creatinine > 2.5 mg/dl) or on renal replacement therapy or albumin level < 3.5 g/dl or symptoms of pitting oedema,
- Systolic pulmonary artery pressure > 60 mmHg
- Known allergy to any of the materials used in the PerQseal Elite device (refer to Investigator's Brochure),
- Subject is unsuitable for surgical repair of the target leg access site,
- Subject has undergone a percutaneous procedure greater than 8F sheath in the target vessel, within the 90-days prior to index procedure,
- Subject has undergone a percutaneous procedure of 8F sheath or less using an absorbable intravascular closure device for haemostasis, in the target vessel, within the 90-days prior to index procedure,
- Subject has undergone a percutaneous procedure of 8F sheath or less using a suture mediated closure device or manual/mechanical pressure for haemostasis in the target vessel, within the 30-days prior to index procedure,
- History of DVT or pulmonary embolism or venous thrombotic event,
- Splenectomy or suffering psoriasis or paraesthesia of the ipsilateral leg,
- Further planned endovascular/catheter-based procedure in the target leg in the 30-days following the index procedure,
- Subject is enrolled in another investigational medical device or drug study,
- Subject has been previously enrolled in this clinical study,
- Subject is unable to maintain ipsilateral leg still during the index procedure (restless leg syndrome),
Current COVID-19 infection (with or without symptoms), recent positive test for COVID-19 within two weeks, or recent exposure to a person with COVID-19 infection within two weeks.
Procedural Exclusion Criteria:
- Anatomically the common femoral vein is substantially posterior to the femoral artery, confirmed by Duplex ultrasound,
- Initial common femoral venous access achieved other than with the use of an ultrasound guided access approach,
- If the venous access is, or suspected of being, via an artery,
- Difficult dilation during initial target femoral vein access (e.g., that damages or kinks dilators) while step-dilating up to the large-bore device,
- During venous puncture, the target femoral vein suspected to have experienced a posterior venous wall needle puncture or underwent > one needle puncture during the primary procedure, with a needle larger than a micropuncture needle (> 21 gauge or > 0.819 mm diameter). (Note: not an exclusion if micropuncture technique under ultrasound guidance used for femoral vein access [Ref. 30, 31]),
- Subject has a tissue tract (i.e., estimated distance from skin entry point to venous anterior surface at venotomy) expected to be greater than 8 cm,
- Significant blood loss requiring transfusion of blood products during primary procedure or within 30-days prior to index procedure,
- Activated clotting time (ACT) > 250 seconds immediately prior to sheath removal or if ACT measurements are expected to be > 250 seconds for more than 24 hours after index procedure,
- Target puncture site is in a vascular graft,
- Target venotomy greater than 26F,
- Target femoral vein diameter is less than 7 mm, based on Duplex ultrasound or angiography,
- Evidence of venous diameter stenosis > 20% within 15 mm proximal or distal to venotomy site based on Duplex ultrasound or angiography,
- Target venotomy has been made in the superficial femoral vein, profunda femoris vein (deep femoral vein), great saphenous vein or located less than 15 mm distal (cranial) to the bifurcation of either the profunda femoris or great saphenous vein and common femoral vein,
- Target venotomy located behind (posterior) or above (cranial) to the inguinal ligament based upon bony landmarks (above femoral head on A-P projection),
- Subjects with an acute haematoma > 4 cm diameter, arteriovenous fistula, pseudoaneurysm or intraluminal thrombosis at the target access site identified intra-procedurally,
- Evidence of bleeding around the primary procedure sheath (VARC type 1/BARC type 2 or higher),
- Intra-procedural (angiographic or Duplex ultrasound) evidence of venous laceration, dissection or stenosis within the femoral vein that would preclude use of the PerQseal Elite device,
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
---|---|
Experimental: Investigational Device Arm (PerQseal Elite- Venous)
Large hole percutaneous venous closure device - PerQseal Elite
|
The term PerQseal Elite used singularly refers to the closure system comprising the closure device and Introducer.
These individually are referred to as: "PerQseal Elite VCD" or "PerQseal Elite closure device" and/or "PerQseal Elite Introducer".
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Primary Safety Endpoint- Combined rate of both Major and Minor access site complications
Time Frame: through 30 Days
|
the combined rate of both Major and Minor access site complications attributable to the PerQseal Elite device§ through 30-days, as adjudicated by the Clinical Events Committee (CEC) as study device related.
|
through 30 Days
|
Primary Effectiveness Endpoint - Time to Haemostasis
Time Frame: 20 Minutes
|
Time to Haemostasis (TTH) defined as elapsed time in minutes from PerQseal Elite (Introducer-sheath and Delivery-device) removal to first observed cessation of common femoral vein (CFV) bleeding (clinically acceptable cessation of venous bleeding), excluding cutaneous or subcutaneous oozing, and in the absence of a developing haematoma.
This is assessed at the end of the index procedure prior leaving the operating room/catheterisation laboratory.
|
20 Minutes
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Secondary Effectiveness Endpoint - Total Closure Time
Time Frame: 40 Minutes
|
Total Closure Time is defined as: Time to Haemostasis (TTH) plus Time to Device Deployment (TTDD).
|
40 Minutes
|
Secondary Effectiveness Endpoint - PerQseal Elite Technical Success Rate
Time Frame: 10 Minutes
|
PerQseal Elite Technical Success Rate is defined as the number of PerQseal Elite devices that are deployed and achieve haemostasis (i.e., cessation of venous bleeding excluding cutaneous or subcutaneous oozing) without need for more than 10 minutes of firm, adjunctive manual compression or alternative treatment (other than adjunctive endovascular ballooning) at target access site, divided by the total number of PerQseal Elite devices where deployment was attempted.
|
10 Minutes
|
Secondary Effectiveness Endpoint - PerQseal Elite Treatment Success Rate
Time Frame: through 30 days
|
PerQseal Elite Treatment Success Rate is defined as the number of subjects who meet PerQseal Elite Technical Success without experiencing a device related Access Site Complication (based on CEC adjudication) through 30-days, divided by the total number of subjects where PerQseal Elite device deployment was attempted.
|
through 30 days
|
Secondary Effectiveness Endpoint -Time to Device Deployment (TTDD)
Time Frame: 20 Minutes
|
Time to Device Deployment is defined as the time from insertion of the PerQseal Elite delivery device into the PerQseal Elite Introducer sheath to complete removal of the PerQseal Elite (delivery device and introducer-sheath) from the subject following PerQseal Elite deployment.
|
20 Minutes
|
Secondary Effectiveness Endpoint - Time to Ambulation
Time Frame: through 24 hours
|
Time to Ambulation is defined as: the elapsed time from PerQseal Elite removal from the subject post deployment until the subject can walk 20 feet/6 meters without venous re-bleeding at the target access site.
This endpoint will be evaluated only for subjects who are ambulatory (e.g., not confined to wheelchair or bed) at the time of enrolment.
|
through 24 hours
|
Collaborators and Investigators
Sponsor
Study record dates
Study Major Dates
Study Start (Estimated)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- P934-00
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Large Hole Percutaneous Venous Closure
-
Vivasure Medical LimitedNot yet recruitingLarge Hole Percutaneous Arterial Closure
-
Vivasure Medical LimitedRecruiting
-
Vivasure Medical LimitedNot yet recruitingLarge Hole Percutaneous Arterial Closure
-
Vivasure Medical LimitedCompleted
-
Vivasure Medical LimitedCompleted
-
Vivasure Medical LimitedRecruitingPercutaneous Arteriotomy ClosureGermany, Netherlands
-
Vivasure Medical LimitedCompletedPercutaneous CFA Arteriotomy ClosureIreland, Germany
-
InSeal Medical Ltd.CompletedPercutaneous Closure of Artery Access SitesIsrael
-
Vivasure Medical LimitedCompletedPercutaneous Common Femoral Artery Arteriotomy ClosureGermany, United Kingdom, Ireland, Belgium
-
InSeal Medical Ltd.TerminatedPercutaneous Closure of Artery Access SitesGermany
Clinical Trials on PerQseal ELITE
-
Vivasure Medical LimitedNot yet recruitingLarge Hole Percutaneous Arterial Closure
-
Vivasure Medical LimitedNot yet recruitingLarge Hole Percutaneous Arterial Closure
-
Vivasure Medical LimitedCompleted
-
ResMedCompletedObstructive Sleep ApneaUnited States
-
Goldman, Butterwick, Fitzpatrick and GroffRecruitingImproved Appearance of the Banana Roll RegionUnited States
-
AllerganCompletedNon-invasive Fat ReductionUnited States, France, Singapore, Sweden, Germany
-
Prim. Prof. Dr. Oliver Findl, MBAUnknown
-
Centre hospitalier de l'Université de Montréal...University of British Columbia; Western University, Canada; University of Saskatchewan and other collaboratorsNot yet recruiting
-
Wake Forest University Health SciencesNovadaq Technologies ULC, now a part of StrykerCompletedVentral HerniaUnited States