Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Comparison of Cardiac Index Measurement Using Right Ventricular Pressure Curve Analysis and Thermodilution Via a Swan-Ganz IQ™ Catheter. (MICAP)

1. června 2026 aktualizováno: Assistance Publique - Hôpitaux de Paris

Comparison of Cardiac Index Measurement by Analysis of the Right Ventricular Pressure Curve and by Thermodilution During Pulmonary Artery Catheterization Using Swan Ganz IQ™.

The pulmonary artery catheter (Swan-Ganz) is a standard tool in intensive care for measuring and monitoring cardiac index by thermodilution. The Swan-Ganz IQ™ model also allows continuous estimation of cardiac index through analysis of the right ventricular pressure wave, which could be useful for rapidly assessing changes in cardiac output during volume expansion response tests. However, the concordance between this continuous method and thermodilution remains poorly studied in real clinical conditions and may vary depending on certain clinical situations. This study therefore aims to compare the cardiac index measured by thermodilution with that estimated by right ventricular pressure waveform analysis based on data collected in clinical practice.

Přehled studie

Postavení

Zatím nenabíráme

Podmínky

Intervence / Léčba

Detailní popis

The pulmonary artery catheter (or Swan-Ganz catheter) is a standard tool for measuring and monitoring cardiac index in intensive care. It measures cardiac index using thermodilution, which is considered the gold standard method. The Swan-Ganz IQ™ model also offers continuous measurement of cardiac index by analyzing the right ventricular pressure waveform. The ability to measure cardiac output continuously would allow pulmonary artery catheterization to be used to assess cardiac output during short procedures, such as tests to predict the response to volume expansion (passive leg raising, expiratory pause), and to evaluate its effect on cardiac index. However, the concordance between cardiac output measured by thermodilution (reference method) and that estimated by the continuous method based on analysis of the right ventricular pressure waveform remains poorly evaluated by independent data in real clinical conditions. Furthermore, this agreement may vary depending on the clinical situation, particularly in the presence of right ventricular dysfunction, tricuspid regurgitation, or left heart failure. In this context, this study aims to compare the cardiac index measured by thermodilution with the cardiac index estimated by analyzing the right ventricular pressure waveform, based on data collected in the clinical setting.

Typ studie

Pozorovací

Zápis (Odhadovaný)

43

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní kontakt

Studijní záloha kontaktů

Studijní místa

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ne

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

Patients hospitalized in medical ICU (of Bicêtre and Angers) with pulmonary arterial catheter (PAC) place as part of routine clinical care.

Popis

Inclusion Criteria:

  • Age ≥ 18 years
  • Hospitalization in intensive care
  • Presence of a Swan-Ganz IQ™ pulmonary artery catheter placed as part of treatment
  • Thermodilution performed by the clinician in charge as part of treatment

Exclusion Criteria:

  • Pregnancy
  • Legal protective measures (guardianship, conservatorship, and deprivation of liberty by court/administrative decision)
  • Refusal of participation by the patient's relatives or the patient themselves.
  • Cardiac output measurements by thermodilution or continuous cardiac output analysis that cannot be used.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Časové okno
Evaluate the concordance between cardiac index values provided according to right ventricular pressure waveform and those measured by thermodilution in patients with septic shock who are monitored by a pulmonary.
Časové okno: 1 day
1 day

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Evaluate the concordance between the continuous cardiac index estimated by the Swan-Ganz IQ™ catheter and the cardiac index measured by thermodilution in patients receiving vasopressor therapy, compared to patients not receiving vasopressor therapy.
Časové okno: 1 day
1 day
Assess whether the agreement between cardiac index measured by thermodilution and that estimated by Swan-Ganz IQ™ varies across different hemodynamic profiles.
Časové okno: 1 day
Investigate whether the agreement between the continuous cardiac index estimated by the Swan-Ganz IQ™ catheter and the cardiac index measured by thermodilution differs according to prespecified hemodynamic phenotypes, particularly in the presence of right ventricular dysfunction, left heart failure, and tricuspid regurgitation grade ≥ 3.
1 day
Assess the concordance between variations in cardiac index measured by thermodilution and those in continuous cardiac index estimated by right ventricular pressure wave analysis, before and after volume expansion performed as part of treatment.
Časové okno: 1 day
1 day
Assess the consistency of changes in cardiac output before and after volume expansion, depending on the use of vasopressors.
Časové okno: 1 day
Assess the concordance between changes in cardiac index measured by thermodilution and those estimated by right ventricular pressure wave analysis before and after volume expansion, depending on the presence or absence of vasopressor treatment at the time of measurement.
1 day
Assess the agreement between changes in cardiac output measured by thermodilution and those estimated continuously by analysis of the right ventricular pressure wave, before and after a change in the dose of norepinephrine.
Časové okno: 1 day
Evaluate the concordance between variations in cardiac index measured by thermodilution and those of continuous cardiac index estimated by right ventricular pressure wave analysis, before and after a change in norepinephrine dose administered as part of treatment.
1 day
Determine the least significant change (LSC) in the continuous cardiac index estimated by the Swan-Ganz IQ™ catheter, based on the observed measurement variability.
Časové okno: 1 day
1 day

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Ředitel studie: Xavier MONNET, PhD, Assistance Publique - Hopitaux de Paris

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Odhadovaný)

10. června 2026

Primární dokončení (Odhadovaný)

10. června 2028

Dokončení studie (Odhadovaný)

10. června 2028

Termíny zápisu do studia

První předloženo

1. června 2026

První předloženo, které splnilo kritéria kontroly kvality

1. června 2026

První zveřejněno (Aktuální)

4. června 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

4. června 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

1. června 2026

Naposledy ověřeno

1. května 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Klinické studie na Septický šok

Klinické studie na Swan-Ganz

Předplatit