- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT03986164
Sofort im ästhetischen Bereich installierte Implantate mit computergestützter Chirurgie
Sofort im ästhetischen Bereich mit computergeführter Chirurgie installierte Implantate: Randomisierte klinische Studie
The objective of this randomized and longitudinal clinical study is to compare the installation of immediate implants in the esthetic zone through computer-guided-surgery and conventional surgery. To this end, 22 patients who need implant-supported replacement on the anterior region of the maxilla will be selected and after extraction will receive: Guided surgery (GS): installation of dental implant with the aid of the virtually planned guide by means of specific software; Conventional surgery (CS): installation of dental implant performed freehand using a conventional surgical guide made by study models.
Studienübersicht
Status
Bedingungen
Detaillierte Beschreibung
The objective of this randomized and longitudinal clinical study is to compare the installation of immediate implants in the esthetic zone through computer-guided-surgery and conventional surgery. To this end, 22 patients who need implant-supported replacement on the anterior region of the maxilla will be selected and after extraction will receive: Guided surgery (GS): installation of dental implant with the aid of the virtually planned guide by means of specific software; Conventional surgery (CS): installation of dental implant performed freehand using a conventional surgical guide made by study models. Tomographies will be performed 10 days after the surgery for the measurement of both linear and angular shifts between the installed implants and the virtual planning. All the clinical and radiographic assessments (Probing Depth, Relative Clinical Insertion Level and the Relative Margin Position of Peri-Implant Mucosa) will be carried out after the surgery and within 6 and 12 months of post-operative. Assesments of the esthetic success (pink/white score) and survival and success of the implant will also be carried out. In the prosthetic part, it will be assessed the abutment mobility; corrective measures for the prothesis; repair on prothesis or abutment. The success and survival assessments of crowns will be done through structure fracture, occlusal roughness, marginal integrity and contour of the restoration. Subsequently, the data will be tabulated, and according to their distribution, the appropriate statistical tests will be applied, considering a 5% index of significance to all the analyses.
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
São Paulo
-
Piracicaba, São Paulo, Brasilien, 13414-903
- Piracicaba Dental School, State University of Campinas
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Patients with sufficient bone volume availability apically and palatally that allows the correct positioning of the implants (Kan et al, 2011);
- Implants with primary stability of 20-45 N (Gallucci et al, 2014);
- Patients with teeth to be extracted in the Class I, II or III corono-radicular position, according to Kan et al. (2011);
- Patients with distance from the bone crest to the point of contact in adjacent teeth less than or equal to 6.5mm (Buser et al 2017).
Exclusion Criteria:
- Presence of diabetes, blood disorders and systemic diseases that prevent the surgical procedure;
- History of radiotherapy in the head or neck region;
- History of treatment with bisphosphonates;
- Pregnant or lactating women;
- Patients with teeth to be extracted in the Class IV corono-radicular position, according to Kan et al. (2011);
- Gingival recession in the teeth indicated for exodontia (Kan et al, 2001);
- Acute infection at the implant site (Morton et al, 2014);
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Doppelt
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Aktiver Komparator: Guided surgery (GS)
Installation of dental implant with the aid of the virtually planned guide by means of specific software |
A minimally traumatic extraction will be performed aiming at the preservation of tissue integrity. After this step, drilling will be performed using a sequence of guides and cutters recommended by the manufacturer of the guided surgery system (SIN Implants®️), system manufacturer for implant installation (Strong SWCM ⌀3.5mm, 11-15mm - SIN Implants®️) in computer-guided surgeries. In the spaces between the implant and the buccal bone plate will be filled with xenogene biomaterial (Geistlich Bio-Oss 0.25-1mm). Immediately after implant installation, the prosthetic component (CPTM 3502-H CM ⌀3.5mm Titanium Provisional Cylinder - T 2mm - SIN Implants) will be placed. If necessary, the sutures of the surgical procedures will be performed with 5.0 monofilament polyamide thread (Nylon Soft Blue®️, NSB/Ultra Soft Blue Monofilament Polyamide - USP 5-0/R 17mm 3/8 circular needle, Techsuture) and will be removed after 7 days. |
|
Aktiver Komparator: Conventional surgery (CS)
Installation of dental implant performed freehand using a conventional surgical guide made by study models |
The sequence of cutters recommended by the manufacturer for this type of surgery and installation of the same type of implant (Strong SWCM ⌀3.5mm, 11-15mm - SIN Implants) will be adopted. The perforations for future insertion of the implants will be performed aiming the installation of the implants with its platform installed with sub-crestal position. The implant should be installed along the palatine wall to obtain primary stability, at the center of the mesio-distal width predetermined by the final restoration, with a minimum distance of 2 mm from the adjacent tooth, and 3 mm from the free gingival margin (Kan et al, 2018). Immediately after installation, the prosthetic component (CPTM 3502-H CM ⌀3.5mm Titanium Provisional Cylinder - T 2mm - SIN Implants) will be placed. The sutures will be performed with 5.0 monofilament polyamide thread (Nylon Soft Blue, NSB/Ultra Soft Blue Monofilament Polyamide - USP 5-0/R 17mm 3/8 circular needle, Techsuture) and will be removed after 7 days. |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Position of the implant
Zeitfenster: Baseline, 10 days
|
Difference between angular position of the implant by computer software and angular position of the implant by free hand ( CoDiagnostiX®️ software version 10.5.0 (Dental Wings GmbH Düsseldorfer, Chemnitz, Germany). |
Baseline, 10 days
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Relative position of peri-implant mucosa
Zeitfenster: 15 days, 6 months, 12 months
|
Distance from stent probing to peri-implant margin tissue |
15 days, 6 months, 12 months
|
|
Peri-implant probing depth
Zeitfenster: 15 days, 6 months, 12 months
|
Distance from peri-implant mucosa to more apical portion of peri-implant sulcus |
15 days, 6 months, 12 months
|
|
Relative clinical attachment level
Zeitfenster: 15 days, 6 months, 12 months
|
Distance from stent probing to more apical portion of peri-implant sulcus |
15 days, 6 months, 12 months
|
|
Pink esthetic score (PES)
Zeitfenster: Baseline, 3, 6 and 12 months
|
Esthetic assessment of the mesial papilla, distal papilla, curvature of the facial mucosa, level of the facial mucosa, and root convexity, as well as the color and texture of the soft tissues, all of which are compared to the contralateral natural tooth. The score for each variable is assigned as follows: complete presence/no discrepancy (score 2), incomplete presence/minor discrepancy (score 1), or absence/major discrepancy (score 0). |
Baseline, 3, 6 and 12 months
|
|
White esthetic score (WES)
Zeitfenster: Baseline, 3, 6 and 12 months
|
Esthetic assessment of the visible portion of the crown, using five criteria: the overall shape of the tooth; the contour and volume of the clinical crown; color (including an assessment of hue and value); surface texture; and translucency and characterization. Each variable is scored as follows: no discrepancy (score 2), minor discrepancy (score 1), or major discrepancy (score 0). The maximum possible score for the index is 10, with a clinical acceptability threshold of 6. |
Baseline, 3, 6 and 12 months
|
|
Crown success
Zeitfenster: Baseline, 3, 6 and 12 months
|
Evaluated according to the United States Public Health Service criteria: structural fracture, ceramic wear, occlusal roughness, marginal integrity, and restoration contour. Crown's scores were Alpha - excellent results; Bravo - clinically acceptable restorations with minor deviations from the ideal; Charlie - clinically repairable defects; Delta - unconditionally clinical problem. Crowns considered successful were those that showed no "Charlie" or "Delta", while surviving crowns included "Charlie". |
Baseline, 3, 6 and 12 months
|
Mitarbeiter und Ermittler
Sponsor
Ermittler
- Studienstuhl: Enilson A Sallum, PhD, Piracicaba Dental School, State University of Campinas
- Hauptermittler: Felipe T Galvão, PhD Student, Piracicaba Dental School, State University of Campinas
- Hauptermittler: Thayane C Businari, PhD Student, Piracicaba Dental School, State University of Campinas
- Hauptermittler: Raíssa Micaella M Machado, PhD, Piracicaba Dental School, State University of Campinas
- Hauptermittler: Altair Antoninha D Cury, PhD, Piracicaba Dental School, State University of Campinas
- Hauptermittler: Márcio Z Casati, PhD, Piracicaba Dental School, State University of Campinas
- Hauptermittler: Vanessa Felipe V Moreno, Phd, School of Odontology of Piracicaba - Unicamp
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 09409619.3.0000.5418
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .