- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT04869813
Valutazione della sarcopenia mediante risonanza magnetica per immagini (SUSIE) (SUSIE)
Caratterizzazione della sarcopenia utilizzando l'impronta digitale della risonanza magnetica e la valutazione dell'imaging spettroscopico della risonanza magnetica fosforosa (SUSIE)
The goal of the proposed research is to investigate Magnetic Resonance (MR) Fingerprinting and P-MRS (Phosphorus-31 MR Spectroscopy) imaging for characterization of skeletal muscle in heart failure patients with sarcopenia. Heart failure patients with and without sarcopenia will be scanned using MR Fingerprinting and an existing Post-exercise phosphocreatine (PCr) recovery MR imaging protocol to obtain characteristic profiles of quantitative T1, T2, and PCr recovery rate.
Panoramica dello studio
Stato
Condizioni
Descrizione dettagliata
Sarcopenia is a common comorbidity and predictor of mortality in heart failure that is characterized by a loss of muscle mass and functional strength. Sarcopenia, in heart failure and other chronic diseases, has been consistently predictive of poor outcomes. However, current tools to identify the presence of sarcopenia, such as functional tests and questionnaires are indirect, non-specific, and not effective until patients have reached an overtly cachectic state and significant muscle deterioration has already occurred. MRI can serve an important, noninvasive role in the assessment and management of sarcopenia by providing insight as to tissue microstructure and mitochondrial function. For example, MRI has shown significant changes in T2 relaxation time, diffusion fractional anisotropy, and lipid content in skeletal muscle of pre-frail/frail patients as compared to healthy volunteers. Post-exercise phosphocreatine (PCr) recovery, evaluated using phosphorus-31 (P) MR spectroscopy Imaging(P-MRSI), has shown impairment of mitochondrial function in pre-frail elderly as compared to active elderly. MR fingerprinting (MRF) is a promising tool for tissue characterization via rapid, robust quantification of T1 and T2 relaxation and has been shown to be accurate and reproducible across sites. Despite applications in neuroimaging and cardiac imaging, MRF has had limited use in musculoskeletal imaging and has not been investigated for use in characterizing sarcopenia. Similarly, P-MRS imaging has not been employed for evaluation of sarcopenia in heart failure patients, a population which may have a unique etiology from other sarcopenia phenotypes. Characterization of sarcopenia may support a range of rapidly developing treatment options in this population. While evidence suggests exercise therapy can improve frailty status, for instance in 39% of patients at 12 month follow-up, it is not yet well-understood which patients will respond to treatment. With a range of treatment options such as nutritional supplementation, hormone therapy, and cardiovascular drugs, MRF and P-MRSI could serve as powerful noninvasive tools to provide a personalized approach for sarcopenic phenotypes, match them to appropriate therapy, and monitor therapeutic response.
Tipo di studio
Iscrizione (Stimato)
Contatti e Sedi
Luoghi di studio
-
-
Ohio
-
Cleveland, Ohio, Stati Uniti, 44195
- Cleveland Clinic
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Heart Failure and Healthy volunteers
Descrizione
Inclusion Criteria:
-
Heart failure patients
- Age ≥40 yrs
- Stable chronic heart failure
- Systolic dysfunction determined by cardiac MRI with left ventricle ejection fraction 40% or less
-
Healthy Volunteers
- Age ≥40 yrs
- No diagnosed heart failure or sarcopenia
Exclusion Criteria:
-
Heart failure patients
• Advanced liver disease, advanced cancer, advanced chronic obstructive pulmonary disease
-
Healthy volunteers (controls)
- Advanced liver disease, advanced cancer, advanced chronic obstructive pulmonary disease
- Contraindications to MRI Contraindications to MRI
- Heart pacemaker/defibrillator
- Electronic/implanted stimulators or devices, including deep brain stimulator, vagus nerve stimulator, bladder stimulator, spine stimulator, neurostimulators; implanted electrodes or wires
- Cochlear implant or other ear implants
- Implanted drug pumps (insulin, narcotic/pain medications, drugs to treat spasticity)
- Programmable shunt
- Aneurysm clips and coils
- Stents
- Filters (for example, blood clot filters)
- Metal fragment in body or eye (eg, BBs, bullets, shrapnel, metal pieces or shavings)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: COHORT
- Prospettive temporali: PROSPECTIVE
Coorti e interventi
Gruppo / Coorte |
|---|
|
Heart failure patients
Inclusion criteria:
Exclusion criteria: • Advanced liver disease, advanced cancer, advanced chronic obstructive pulmonary disease Contraindications to MRI such as:
|
|
Healthy volunteers (Controls)
Inclusion criteria:
Exclusion criteria • Advanced liver disease, advanced cancer, advanced chronic obstructive pulmonary disease Contraindications to MRI such as:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Anticipated Results
Lasso di tempo: 3 years
|
This proposal is expected to produce information as to the change in T1, T2, muscle area, fat fraction, and PCr recovery rate values for heart failure patients with sarcopenia as compared to non-sarcopenic volunteers. Future work will expand upon this study to evaluate to progression of sarcopenia, and evaluate the prognostic value of imaging biomarkers (T1, T2, muscle area, fat fraction, PCr recovery) in predicting heart failure and sarcopenic related outcomes. |
3 years
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: W. H. Wilson Tang, MD, The Cleveland Clinic
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 21-124
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .