어린이의 피부색과 맥박산소측정기 정확도 사이의 관계 평가 (PACH)

2026년 9월 23일 업데이트: University of Pennsylvania

This multisite study seeks to understand whether and how pulse oximeter accuracy varies across children with different skin colors in real world clinical settings. Many factors can affect how well pulse oximeters work; for example, movement and even fingernail polish. Some studies in adults show that skin color may also affect the pulse oximeter reading. In this study, we will explore pulse oximeter accuracy in children of all skin colors who are undergoing cardiac catheterizations. The study will address limitations of prior work by objectively measuring skin color across multiple dimensions of color and comparing the the pulse oximeter reading to the "gold standard" blood sample measurement.

연구 개요

상태

모병

상세 설명

This multisite, prospective, observational study will be conducted in a population of children under 18 years old who are undergoing cardiac catheterization. The primary aim of the study is to quantify pulse oximeter accuracy in children with varying skin colors. Children undergoing cardiac catheterization are a unique population in which to study pulse oximeter accuracy because they have a wide range of baseline arterial oxygen saturations secondary to their cardiac conditions, allowing for evaluation of pulse oximeter accuracy across a range of arterial oxygen saturations. Children undergoing cardiac catheterization are continuously monitored with pulse oximeters and also have direct measurement of arterial blood oxygen via co-oximeter as part of routine care. The results of this study will contribute much needed knowledge about pulse oximeter accuracy in children to better understand potential clinical implications.

Dimensions of skin colors (melanin index, redness etc) will be objectively measured using spectrophotometry. During and after the catheterization procedure, clinical data already collected during the course of clinical care will be recorded by the study team, including pulse oximeter output and arterial blood oxygen saturation measurement obtained during the procedure. The primary outcome of interest is the difference between the pulse oximeter reading and the direct measurement of arterial blood oxygen.

연구 유형

관찰

등록 (추정된)

650

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

연구 연락처 백업

연구 장소

    • New York
      • New York, New York, 미국, 10032
        • 아직 모집하지 않음
        • Columbia University Medical Center
        • 연락하다:
    • Pennsylvania
      • Philadelphia, Pennsylvania, 미국, 19104
        • 모병
        • Children's Hospital of Philadelphia
        • 연락하다:
    • Texas
      • Houston, Texas, 미국, 77030

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

4주 (어린이, 성인)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

샘플링 방법

비확률 샘플

연구 인구

Children who are old undergoing a cardiac catheterization procedure at one of the data collection sites and is having a procedure that typically involves direct arterial oxygen saturation measurement by co-oximeter from a location reflective of systemic saturation.

설명

Inclusion Criteria:

  • Child is between 1 month and 18 years old
  • Child is undergoing a cardiac catheterization procedure that typically involves direct arterial oxygen saturation measurement by co-oximeter from a location reflective of systemic saturation.

Exclusion Criteria:

  • Child previously participated in the study
  • Child has differential cyanosis across extremities
  • Child is receiving an intravenous vasoconstrictor prior to procedure
  • Child has a ventricular assist device (VAD)

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 관찰 모델: OTHER
  • 시간 관점: PROSPECTIVE

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Pulse Oximeter Bias
기간: The variables used to calculate Pulse Oximeter Bias are collected once during the cardiac catheterization procedure. This is a cross-sectional observational study; participants are not followed longitudinally.

Pulse oximeter bias is the difference between the pulse oximeter value (estimated % oxygen saturation measured via pulse oximeter) and the gold standard measure of arterial oxygen saturation (% oxygen saturation in blood sample measured via co-oximeter).

The variables used to calculate Pulse Oximeter Bias are collected once during the cardiac catheterization procedure. This is a cross-sectional observational study; participants are not followed longitudinally.

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Halley Ruppel, PhD, University of Pennsylvania
  • 수석 연구원: Michael O'Byrne, MD, MSCE, Children's Hospital of Philadelphia

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2024년 8월 14일

기본 완료 (추정된)

2028년 12월 1일

연구 완료 (추정된)

2028년 12월 1일

연구 등록 날짜

최초 제출

2024년 7월 22일

QC 기준을 충족하는 최초 제출

2024년 7월 30일

처음 게시됨 (실제)

2024년 7월 31일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 9월 24일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 9월 23일

마지막으로 확인됨

2026년 9월 1일

추가 정보

이 연구와 관련된 용어

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

예

IPD 계획 설명

Per NIH Data Management and Sharing Policy, study data will be contributed to a repository available to other researchers. Study data will be de-identified.

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .