- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05665231
Differences Between Two Type Implants in Post-extraction Alveolus
Morphometric, Imaging and Photographic Comparison of Peri-implant Tissues Between V3 and C1 Mis ® Implants in Post-extraction Alveolus in the Anterior Region of the Maxilla
Study Overview
Status
Conditions
Intervention / Treatment
- Other: A - Bone defect (clinical variables)
- Other: B- Bacterial plaque index (O'Leary index)(clinical variables)
- Other: C- Probing depth
- Other: D- Bleeding on probing
- Other: E- Gingival phenotype
- Other: F- Implant insertion torque (Clinical variables)
- Other: G- Implant stabilization quotient (ISQ) (clinical variables)
- Other: Morphometric results (Direct measurements - millimeter)
- Other: Morphometric results (plaster models measurements - millimeter)
- Other: Imaging Results (X-ray) (millimeter)
- Other: Imaging Results (CBCT)(millimeter)
- Other: Photographic results PES/WES index
Detailed Description
The study is a prospective randomized clinical trial performed by a single investigator, without a control group. The project was designed in 2016 and the participants were recruited between 2017 and 2021.
Patients who met the inclusion criteria were recruited by the Unit of Oral Surgery and Implantology of the University of Porto from 2017 to 2021. The patients were fully informed of the characteristics of the study and were invited to participate. A complete medical history was taken for each of the patients, and they also underwent a thorough oral examination. The investigation was carried out in accordance with the criteria recommended in the CONSORT Guidelines.
Sample characterization The sample will consist of clinical cases of unitary tooth loss in the region of incisors, canines, and maxillary premolars of patients from the clinic of the Faculty of Dental Medicine of the University of Porto. The study follows ethical principles of the Ethics Committee of the Faculty of Dental Medicine, University of Porto, and guidelines from the Declaration of Helsinki for clinical trials with humans.
Thus, after informed consent, the patients will be randomly grouped into 2 groups, through a closed letter draw:
Group I- patients submitted to the protocol of immediate placement of the V3 Mis® implant; Group II- patients submitted to the protocol of immediate placement of C1 MIS® implant.
Surgical protocol
Surgical protocol for implant placement (1st surgical phase):
Starting with a local anesthetic administration, the incision and elevation of the mucoperiosteal flap are performed. Then the tooth is atraumatically extracted with odontosection and use of mucoperiosteal elevators, and the socket is cleaned with saline solution. After this is complete, the osteotomy for implant placement is performed, and the implant and the healing cap are placed. Finally, the implant is submerged and the surgical wound is sutured with non-resorbable 4/0 polyamide thread. For the provisional a Maryland crown was performed. Individuals are monitored monthly during the healing phase, and sutures are removed after 7 days.
Pre- and post-operative therapy includes:
- Antibiotic: amoxicillin, 1g (twice a day for 8 days), and in case of allergy, clarithromycin 500mg (twice a day for 8 days). Administration started on the day of surgery;
- Anti-inflammatories (diclofenac 50mg, twice a day, for 4 to 5 days);
- Chlorhexidine (0.2%) rinses (twice a day for 21 days).
Surgical protocol for placement of a healing abutment (2nd surgical phase):
Starting with a local anesthetic administration, the incision and elevation of the mucoperiosteal flap are performed. After, the healing screw is removed and the implant healing abutment (with 3x5,8mm) is placed. Finally, the surgical wound is sutured with non-resorbable 4/0 polyamide thread. Suture removal is performed after 7 days. After healing, impressions were made for the fabrication of a screw-retained cad-cam crown with platform switching concept.
The investigators chose open flap implant placement without bone or connective graft placement, or immediate provisional, and direct measurement of hard and soft tissues to study the differences between implants. The goal is to evaluate only the effect of the type of coronal shape implant, minimizing the influence of other factors that could lead to bias errors.
- Evaluations over time
T-1 - First visit pre-operative:, Morphometric evaluation (clinical direct measurements and plaster models measurements), imaging (X-ray and CBCT) and photographic (PES/WES) analysis.
T0 - Extraction tooth: Morphometric (clinical direct measurements) and imaging (X-ray) evaluation.
T1 - Implant placed (1st surgical phase): Morphometric (clinical direct measurements) and imaging evaluation (X-ray) evaluation.
T2 - 2 months submerged: Morphometric evaluation (clinical direct measurements).
T3 - Healing abutment (2nd surgical phase - 4 months): Morphometric evaluation (clinical direct measurements).
T3c - Definitive Crown: Morphometric evaluation(clinical direct measurements).
T4 - 6 months osteointegration: Morphometric evaluation (clinical direct measurements and plaster models measurements), imaging (X-ray and CBCT) and photographic (PES/WES) analysis.
4 - Observed clinical variables:
A- Bone defect: the edentulous space to be rehabilitated will be characterized in terms of the morphometric level of the existing defect in the vestibular cortical, according to the classification by Caplanis N., at time T0, in EDS-1 or EDS-2.
B- Bacterial plaque index (O'Leary index): an analysis will be performed for existing plaque on teeth adjacent to the surgical site using a dichotomous score (0 = no visible plaque at the soft tissue margin, 1 = visible plaque at the soft tissue margin).
C- Probing depth: analysis of the probing depth of the teeth adjacent to the site to be treated at 6 points: mesiobuccal, vestibular, distobuccal, mesiopalatal, palatine, distopalatal. The recordings will be carried out with a CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe.
D- Bleeding on probing: performed at the 6 locations around adjacent teeth when analyzing the probing depth.
E- Gingival phenotype: identified by clinical inspection with a periodontal probe.
F- Implant insertion torque: recording of implant insertion torque during placement (T1).
G- Implant stabilization quotient (ISQ): determination of the implant stability coefficient at the time of implant placement (T1) and in the 2nd surgical phase (T3) using the Osstell® device, the resonance frequency analysis is performed.
5 - Morphometric analysis
Measurements to be assessed:
- interdental distance: distance measured using the straight gauge between adjacent teeth at the bone crest.
- bucco-palatal distance (BPD): distance measured by the thickness gauge in the midline of the edentulous space between the buccal edge of the buccal cortex to the palatal edge of the palatal cortex.
- presence of papilla: evaluation through the pink aesthetics index (Pink Esthetic Score - PES, proposed by Fürhauser and collaborators, white aesthetics index (White Esthetic Score - WES, proposed by Belser UC).
- buccal cortical distance: thickness of the buccal cortical through the thickness gauge, measured at the midline of the alveolus.
- palatal cortical distance: thickness of the palatal cortical through the thickness gauge, measured at the midline of the alveolus.
- mesial cortical distance: thickness of the palatal cortical through the thickness gauge, measured at the midline of the alveolus.
- distal cortical distance: thickness of the palatal cortical through the thickness gauge, measured at the midline of the alveolus.
- jumping distance: distance between the inner of the buccal or palatal or mesial or distal cortex and the buccal surface of the implant measured using the periodontal probe;
- implant - cemento-enamel junction (CEJ) of adject teeth distance: determination of the vertical dimension from the occlusal surface of the implant to the cemento-enamel junction of adjacent teeth with a periodontal probe, in mesial and distal sides.
- buccal cortical wall-implant distance: using the periodontal probe, horizontal dimension between the buccal surface of the cortical and the buccal surface of the implant, at buccal, palatal, mesial and distal cortical.
- jumping distance space depth: maximum depth of the space between the buccal cortex and the implant wall through the periodontal probe at buccal, palatal, mesial and distal cortical.
- distance from the implant position depth to the buccal bone crest: vertical dimension of the occlusal surface of the implant in relation to the bone crest through the periodontal probe, at buccal, palatal, mesial and distal cortical.
- distance from the buccal cortex to the center of the implant: horizontal dimension from the buccal edge of the buccal cortex to the center of the implant with a periodontal probe, at buccal, palatal, mesial and distal cortical.
- implant diameter: diameter of the implant.
- Implant length: length of the implant.
- soft tissue thickness: Soft tissue thickness was assessed using the thickness gauge at the buccal and palatal mucosa.
- global bone volume: using the periodontal probe and thickness gauge, horizontal dimension between the buccal surface of the buccal cortical and the lingual surface of the palatal cortical, at the bone crest and 3 mm below this.
- global volume: Soft and hard tissue thickness was assessed using the periodontal probe and thickness gauge, at the crest and 3 mm below this.
- alveolus buccal-palatal distance: with periodontal probe.
- alveolus mesa-distal distance: with periodontal probe.
alveolus depth: with periodontal probe.
The morphometric analysis will be performed in all patients as follows:
5.1- Clinical direct measurements in mouth:
Direct measurements will be carried out using a thickness gauge and periodontal probe ( CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe), with a 0.5mm. The appropriate measures will be applied, according to the chronograms times.
5.2- Plaster models measurements: Initial impressions will be made at time T-1 to prepare a thermoformed gutter with calibration traces for measurements at different surgical times.
Preparation of plaster models at times T-1 and T4 and different measurements will be evaluated.
6 - Imaging analysis
6.1- Periapical X-ray: Use of the parallelism technique and use of thermoformed gutter with horizontal and vertical plane marking. Periapical x-rays will be performed at times T-1, T1,T4.
6.2- Cone Beam Computerized Tomography (CBCT): In the analysis of maxillary computed tomography, at times T-1 and T4, with radiographic guide.
7- Photographic analysis:
Photographs will be taken using a Canon 450D device, a Canon Macro Lens EF 100mm lens and a Macro Ring Lite MR-14EX circular flash, with an image ratio of 1:1.
7.1- Extra-oral photographs: Initial (T-1) and final (T4) extraoral photographs will be taken at a distance of 2.5 m for replication and with reference to the occlusal plane. The reference will be the midsagittal plane and the Frankfurt plane, and the frontal photograph will be taken in the resting and smiling position, along with a profile photograph of the patient at rest and smiling.
7.2- Intra-oral photographs: Intraoral photographs will be taken during the treatment phases T-1 and T4 measuring a distance of 40 cm for replication and with reference to the occlusal plane. For this, lip retractors, intraoral mirrors, and black backgrounds will be used. Frontal photography in maximum occlusion, left and right lateral photography with only two adjacent teeth, and upper and lower occlusal photography will be performed.
Evaluated measurements:
The presence of papilla; The PES and WES index was evaluated through the analysis of photographs.
8- Statistical analysis
The sample size was calculated from G*Power 3.1.9.6 considering F tests - ANOVA with Repeated measures, moderate effect size (f=0.30), α= 0.05, Power (1-β err prob)=0.95 and 2 groups of implants evaluated in 7 times.
A descriptive analysis will be presented to characterize the qualitative and quantitative variables (gender, race, and age) presented in the form of graphs and summary tables. The statistical techniques to be adopted will be in accordance with the nature of the variables under study.
Therefore, for the evaluation of quantitative measures in time, the analysis will be proposed through the ANOVA test with repeated measures with one factor (type of implant), after verifying the conditions of normality and sphericity of the variables. Measurement error control (collection of three measurements in each observation) and examiner calibration (intra-operator variability).
For processing the results, the IBM Statistics software version 24.0 will be used. The decision rule will be for a statistical significance level of 5%.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Porto, Portugal, 4200-393
- Faculty of Dental Medicine, Porto University
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients aged 18 and over
- Patients with understanding and free decision-making for informed consent
- Patients who need rehabilitation of a tooth in the region of incisors, canines, or maxillary premolars
- Patients with EDS-1 or EDS-2 dental sockets, according to Caplanis N. classification.
Exclusion Criteria:
- Patients with systemic pathologies that contraindicate the surgical procedure;
- Prolonged Non-steroidal anti-inflammatory drugs (NSAIDs);
- Bisphosphonate therapy;
- Lack of opposing teeth on implant site;
- Lack of adjacent teeth on implant site;
- Dental-sockets with total loss of one of the cortical;
- Untreated periodontal pathology;
- Pathology or circumstance that prevents patients from attending routine check-ups;
- Patients who smoke more than 10 cigarettes/day. Smokers are advised to reduce or stop smoking.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Quadruple
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
---|---|
Experimental: V3 Mis® implant
Implant with coronal triangular neck
|
At T0, the edentulous space to be rehabilitated will be characterized in terms of the morphometric level of the existing defect in the vestibular cortical, according to the classification by Caplanis N. in EDS-1 or EDS-2.
At time T-1 and T4, the investigator will analyse the existing plaque on teeth adjacent to the surgical site using a dichotomous score (0 = no visible plaque at the soft tissue margin, 1 = visible plaque at the soft tissue margin).
The result will be present in percentage (0% (better)-100%(worse)) and will describe the change between T-1 and T4, and compare the results between implants type.
At Time T-1 and T4, the investigators will analyse the probing depth of the teeth adjacent to the site to be treated at 6 points: mesiobuccal, vestibular, distobuccal, mesiopalatal, palatine, distopalatal.
The recordings will be carried out with a CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe.The result will be present in millimeters.
The change between T-1 and T4 is also going to be analysed and compare implants results.
At time T-1 and T4, the investigators will analyse the bleeding on probing of the teeth adjacent to the site to be treated at 6 points: mesiobuccal, vestibular, distobuccal, mesiopalatal, palatine, distopalatal.
The recordings of bleeding on probing will be carried out with a CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe.The result will be present in percentage (0% (better)-100%(worse)) and will describe the change between T-1 and T4 and compare between implants type.
At time T-1, the identification of the gingival phenotype is performed by clinical inspection with a periodontal probe.
The gingival phenotype will be classified as thin, moderate or thick.
The investigators will compare implant results.
Recording of implant insertion torque, in Ncm during placement in T1, and compare implants results.
Determination of the implant stability coefficient at the time of implant placement (T1) and in the 2nd surgical phase (T3) using the Osstell® device (minimum 1; maximum 100; high stability when ≥70) and analysis of the change between T1 and T3 and different implants results.
Compare Direct measurements (millimeters) at the different times intervention with periodontal probe or gauge and analyse the change between times and compare implant results. In T-1, T2 and T3c and T4 the investigators will evaluate interdental distance; BPD, cortical bone, papilla and volume, corresponding of measurements: a,b,c and r. In T0, the investigators will evaluate interdental distance; BPD, cortical, bone and global volume corresponding to measurements: a, b, c, d, e, q, r, s, t, and u). In T1 e T3, the investigators will evaluate interdental distance; BPD, cortical, bone and global volume, implant parameter corresponding to measurements: a, b, d, e, f, g, h, I, j, k, l, m, n, p, q, r and ISQ value. Preparation of plaster models at times T-1 and T4 and the following measurements (millimeter) will be evaluated with the use of periodontal probe or gauge and will analyse the change between T-1 and T4 and compare implants results:
r. global volume. The investigator will measure (millimeters, using the imaging software virtual ruler) the results of digital X-ray at times T-1, T1,T4 and analyse the variation and compare implants results. The measurements are: a. interdental distance; i. implant - cemento-enamel junction (CEJ) of adject teeth distance; l. distance from the implant position depth to the buccal bone crest; n. implant diameter; o. implant length. The investigator will measure (millimeters, using the imaging software virtual ruler) the results of CBCT at times T-1 and T4, analyse the variation and compare implants results. The measurements are:
d. buccal cortical distance; e. palatal cortical distance; f. mesial cortical distance; g. distal cortical distance; h. jumping distance; j. buccal cortical wall-implant distance; k. jumping distance space depth; l. distance from the implant position depth to the buccal bone crest; m. distance from the buccal cortex to the center of the implant; n. implant diameter; o. Implant length; q. global bone volume; r. global volume; s. alveolus buccal-palatal distance; t. alveolus mesial-distal distance; u. alveolus depth.
The investigator will analyse the intraoral photographs to describe the Pes/Wes index, in time T-1 (initial) and T4 (final), and compare the PES/WES results between implants.The score will range on 0-10, the best score is ≥8.
|
Active Comparator: C1 MIS® implant
Implant with coronal cylindrical neck (regular)
|
At T0, the edentulous space to be rehabilitated will be characterized in terms of the morphometric level of the existing defect in the vestibular cortical, according to the classification by Caplanis N. in EDS-1 or EDS-2.
At time T-1 and T4, the investigator will analyse the existing plaque on teeth adjacent to the surgical site using a dichotomous score (0 = no visible plaque at the soft tissue margin, 1 = visible plaque at the soft tissue margin).
The result will be present in percentage (0% (better)-100%(worse)) and will describe the change between T-1 and T4, and compare the results between implants type.
At Time T-1 and T4, the investigators will analyse the probing depth of the teeth adjacent to the site to be treated at 6 points: mesiobuccal, vestibular, distobuccal, mesiopalatal, palatine, distopalatal.
The recordings will be carried out with a CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe.The result will be present in millimeters.
The change between T-1 and T4 is also going to be analysed and compare implants results.
At time T-1 and T4, the investigators will analyse the bleeding on probing of the teeth adjacent to the site to be treated at 6 points: mesiobuccal, vestibular, distobuccal, mesiopalatal, palatine, distopalatal.
The recordings of bleeding on probing will be carried out with a CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe.The result will be present in percentage (0% (better)-100%(worse)) and will describe the change between T-1 and T4 and compare between implants type.
At time T-1, the identification of the gingival phenotype is performed by clinical inspection with a periodontal probe.
The gingival phenotype will be classified as thin, moderate or thick.
The investigators will compare implant results.
Recording of implant insertion torque, in Ncm during placement in T1, and compare implants results.
Determination of the implant stability coefficient at the time of implant placement (T1) and in the 2nd surgical phase (T3) using the Osstell® device (minimum 1; maximum 100; high stability when ≥70) and analysis of the change between T1 and T3 and different implants results.
Compare Direct measurements (millimeters) at the different times intervention with periodontal probe or gauge and analyse the change between times and compare implant results. In T-1, T2 and T3c and T4 the investigators will evaluate interdental distance; BPD, cortical bone, papilla and volume, corresponding of measurements: a,b,c and r. In T0, the investigators will evaluate interdental distance; BPD, cortical, bone and global volume corresponding to measurements: a, b, c, d, e, q, r, s, t, and u). In T1 e T3, the investigators will evaluate interdental distance; BPD, cortical, bone and global volume, implant parameter corresponding to measurements: a, b, d, e, f, g, h, I, j, k, l, m, n, p, q, r and ISQ value. Preparation of plaster models at times T-1 and T4 and the following measurements (millimeter) will be evaluated with the use of periodontal probe or gauge and will analyse the change between T-1 and T4 and compare implants results:
r. global volume. The investigator will measure (millimeters, using the imaging software virtual ruler) the results of digital X-ray at times T-1, T1,T4 and analyse the variation and compare implants results. The measurements are: a. interdental distance; i. implant - cemento-enamel junction (CEJ) of adject teeth distance; l. distance from the implant position depth to the buccal bone crest; n. implant diameter; o. implant length. The investigator will measure (millimeters, using the imaging software virtual ruler) the results of CBCT at times T-1 and T4, analyse the variation and compare implants results. The measurements are:
d. buccal cortical distance; e. palatal cortical distance; f. mesial cortical distance; g. distal cortical distance; h. jumping distance; j. buccal cortical wall-implant distance; k. jumping distance space depth; l. distance from the implant position depth to the buccal bone crest; m. distance from the buccal cortex to the center of the implant; n. implant diameter; o. Implant length; q. global bone volume; r. global volume; s. alveolus buccal-palatal distance; t. alveolus mesial-distal distance; u. alveolus depth.
The investigator will analyse the intraoral photographs to describe the Pes/Wes index, in time T-1 (initial) and T4 (final), and compare the PES/WES results between implants.The score will range on 0-10, the best score is ≥8.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
A - Bone defect (clinical variables)
Time Frame: T0
|
At T0, the edentulous space to be rehabilitated will be characterized in terms of the morphometric level of the existing defect in the vestibular cortical, according to the classification by Caplanis N. in EDS-1 or EDS-2.
|
T0
|
B- Bacterial plaque index (O'Leary index)(clinical variables)
Time Frame: 6 months
|
At time T-1 and T4, the investigator will analyse the existing plaque on teeth adjacent to the surgical site using a dichotomous score (0 = no visible plaque at the soft tissue margin, 1 = visible plaque at the soft tissue margin).
The result will be present in percentage (0% (better)-100%(worse)) and will describe the change between T-1 and T4, and compare the results between implants type.
|
6 months
|
C- Probing depth (clinical variables)
Time Frame: 6 months
|
At Time T-1 and T4, the investigators will analyse the probing depth of the teeth adjacent to the site to be treated at 6 points: mesiobuccal, vestibular, distobuccal, mesiopalatal, palatine, distopalatal.
The recordings will be carried out with a CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe.The result will be present in millimeters.
The change between T-1 and T4 is also going to be analysed and compare implants results.
|
6 months
|
D- Bleeding on probing (clinical variables)
Time Frame: 6 months
|
At time T-1 and T4, the investigators will analyse the bleeding on probing of the teeth adjacent to the site to be treated at 6 points: mesiobuccal, vestibular, distobuccal, mesiopalatal, palatine, distopalatal.
The recordings of bleeding on probing will be carried out with a CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe.The result will be present in percentage (0% (better)-100%(worse)) and will describe the change between T-1 and T4 and compare between implants type.
|
6 months
|
E- Gingival phenotype (clinical variables)
Time Frame: T-1
|
At time T-1, the identification of the gingival phenotype is performed by clinical inspection with a periodontal probe.
The gingival phenotype will be classified as thin, moderate or thick.
The investigators will compare implant results.
|
T-1
|
F- Implant insertion torque (Clinical variables)
Time Frame: T1
|
Recording of implant insertion torque, in Ncm during placement in T1, and compare implants results.
|
T1
|
G- Implant stabilization quotient (ISQ) (clinical variables)
Time Frame: 6 months
|
Determination of the implant stability coefficient at the time of implant placement (T1) and in the 2nd surgical phase (T3) using the Osstell® device (minimum 1; maximum 100; high stability when ≥70) and analysis of the change between T1 and T3 and different implants results.
|
6 months
|
Morphometric evaluation (clinical direct measurements)
Time Frame: 6 months
|
Compare Direct measurements (millimeters) at the different times intervention with periodontal probe or gauge and analyse the change between times and compare implant results. In T-1, T2 and T3c and T4 the investigators will evaluate interdental distance; BPD, cortical bone, papilla and volume, corresponding of measurements: a,b,c and r. In T0, the investigators will evaluate interdental distance; BPD, cortical, bone and global volume corresponding to measurements: a, b, c, d, e, q, r, s, t, and u). In T1 e T3, the investigators will evaluate interdental distance; BPD, cortical, bone and global volume, implant parameter corresponding to measurements: a, b, d, e, f, g, h, I, j, k, l, m, n, p, q, r and ISQ value. |
6 months
|
Morphometric evaluation (plaster models measurements)
Time Frame: 6 months
|
Preparation of plaster models at times T-1 and T4 and the following measurements (millimeter) will be evaluated with the use of periodontal probe or gauge and will analyse the change between T-1 and T4 and compare implants results:
r. global volume. |
6 months
|
Imaging periapical X-ray evaluation (millimeter)
Time Frame: 6 months
|
The investigator will measure (millimeters, using the imaging software virtual ruler) the results of digital X-ray at times T-1, T1,T4 and analyse the variation and compare implants results. The measurements are: a. interdental distance; i. implant - cemento-enamel junction (CEJ) of adject teeth distance; l. distance from the implant position depth to the buccal bone crest; n. implant diameter; o. implant length. |
6 months
|
Cone Beam Tomography (CBCT) evaluation (millimeter)
Time Frame: 6 months
|
The investigator will measure (millimeters, using the imaging software virtual ruler) the results of CBCT at times T-1 and T4, analyse the variation and compare implants results. The measurements are:
d. buccal cortical distance; e. palatal cortical distance; f. mesial cortical distance; g. distal cortical distance; h. jumping distance; j. buccal cortical wall-implant distance; k. jumping distance space depth; l. distance from the implant position depth to the buccal bone crest; m. distance from the buccal cortex to the center of the implant; n. implant diameter; o. Implant length; q. global bone volume; r. global volume; s. alveolus buccal-palatal distance; t. alveolus mesial-distal distance; u. alveolus depth. |
6 months
|
PES/WES index - Photography results
Time Frame: 6 months
|
The investigator will analyse the intraoral photographs to describe the Pes/Wes index, in time T-1 (initial) and T4 (final), and compare the PES/WES results between implants.The score will range on 0-10, the best score is ≥8.
|
6 months
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Osseointegration survival rate
Time Frame: 6 months
|
At the surgical second phase, it will observe the percentage of dental implant osseointegration in each group at time T4.
|
6 months
|
Biological complication
Time Frame: 6 months
|
It will indicate and describe biological complication if they occur, at time T4.
|
6 months
|
Prosthetic complication
Time Frame: 6 months
|
It will indicate and describe the prosthetic complication if they occur, at time T4.
|
6 months
|
Collaborators and Investigators
Sponsor
Investigators
- Study Director: Ricardo Faria Almeida, PhD, Faculdade de Medicina Dentária da Universidade do Porto
Publications and helpful links
General Publications
- Buser D, Chappuis V, Belser UC, Chen S. Implant placement post extraction in esthetic single tooth sites: when immediate, when early, when late? Periodontol 2000. 2017 Feb;73(1):84-102. doi: 10.1111/prd.12170.
- Araujo MG, Sukekava F, Wennstrom JL, Lindhe J. Tissue modeling following implant placement in fresh extraction sockets. Clin Oral Implants Res. 2006 Dec;17(6):615-24. doi: 10.1111/j.1600-0501.2006.01317.x.
- Chappuis V, Araujo MG, Buser D. Clinical relevance of dimensional bone and soft tissue alterations post-extraction in esthetic sites. Periodontol 2000. 2017 Feb;73(1):73-83. doi: 10.1111/prd.12167.
- Caplanis N, Lozada JL, Kan JY. Extraction defect assessment, classification, and management. J Calif Dent Assoc. 2005 Nov;33(11):853-63.
- Perez-Albacete Martinez MA, Perez-Albacete Martinez C, Mate Sanchez De Val JE, Ramos Oltra ML, Fernandez Dominguez M, Calvo Guirado JL. Evaluation of a New Dental Implant Cervical Design in Comparison with a Conventional Design in an Experimental American Foxhound Model. Materials (Basel). 2018 Mar 21;11(4):462. doi: 10.3390/ma11040462.
- Li Manni L, Lecloux G, Rompen E, Aouini W, Shapira L, Lambert F. Clinical and radiographic assessment of circular versus triangular cross-section neck Implants in the posterior maxilla: A 1-year randomized controlled trial. Clin Oral Implants Res. 2020 Sep;31(9):814-824. doi: 10.1111/clr.13624. Epub 2020 Jun 29.
- Araujo MG, da Silva JCC, de Mendonca AF, Lindhe J. Ridge alterations following grafting of fresh extraction sockets in man. A randomized clinical trial. Clin Oral Implants Res. 2015 Apr;26(4):407-412. doi: 10.1111/clr.12366. Epub 2014 Mar 12.
- Belser UC, Grutter L, Vailati F, Bornstein MM, Weber HP, Buser D. Outcome evaluation of early placed maxillary anterior single-tooth implants using objective esthetic criteria: a cross-sectional, retrospective study in 45 patients with a 2- to 4-year follow-up using pink and white esthetic scores. J Periodontol. 2009 Jan;80(1):140-51. doi: 10.1902/jop.2009.080435.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- 080237
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Dental Implants, Single-Tooth
-
Alexandria UniversityActive, not recruitingDental Implants, Single-ToothEgypt
-
Institut Straumann AGAvaniaActive, not recruitingDental Implants, Single-ToothGermany, Hong Kong, Portugal
-
SIA AdentaRecruitingDental Anxiety | Female | Dental Implants | Male | Humans | Osseointegration | Guided Surgery | Dental Implants, Single-ToothLatvia
-
University of LiegeITI International Team for Implantology, SwitzerlandCompletedDental Implantation | Dental Implants | Soft Tissue Inflammation | Histology | Immunohistochemistry | Dental Implants, Single-ToothBelgium
-
The University of Hong KongRecruitingDental Implant Failed | Dental Implants | Single Tooth LostGermany, Hong Kong
-
University of BernNot yet recruitingComplications | Patient Reported Outcome Measures | Cost-Benefit Analysis | Cost-effectiveness | Esthetic Zone | Single Tooth Dental Implant | Single Tooth Lost | Accuracy of Dental Implants | Dimensional Changes | Implant Survival and Success | Frequency of Treatment ProtocolSwitzerland
-
University of BernCompletedJaw, Edentulous, Partially | Dental Implants, Single-tooth | Grafting BoneSwitzerland
-
Christopher BarwaczCompletedEsthetics, Dental | Dental Implant, Single-ToothUnited States
-
Universidad de GranadaBTI Biotechnology InstituteActive, not recruiting
-
Hams Hamed AbdelrahmanCompletedDental Implants | Tooth ExtractionEgypt
Clinical Trials on A - Bone defect (clinical variables)
-
Germans Trias i Pujol HospitalWithdrawnPsoriasis | Major Depressive Disorder | Neuroinflammation | Cognitive Symptom | Immunological AbnormalitySpain
-
AO Innovation Translation CenterNot yet recruitingBone Loss | Limb FractureGermany, United States, Korea, Republic of, Netherlands, Switzerland, United Kingdom
-
Cho Ray HospitalCommonwealth Scientific and Industrial Research Organisation, Australia; 3...RecruitingBone Loss | Defect LimbVietnam
-
Carag AGCompleted
-
University Hospital, BordeauxUniversité Victor Segalen Bordeaux 2CompletedParkinson DiseaseFrance
-
Cairo UniversityRecruiting
-
ZhanghaoRecruiting
-
Tehran University of Medical SciencesUnknownAtherosclerosisIran, Islamic Republic of
-
Instituto Materno Infantil Prof. Fernando FigueiraCompletedVitamin A Deficiency | HypovitaminosisBrazil
-
Mansoura UniversityActive, not recruiting