- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT05936619
MindEx: Nový, multifokální, kognitivní systém rozhraní mozek-stroj
This research study is being done to develop a novel brain-computer interface (BCI) technology that can enable severely paralyzed individuals to interact with the world through direct brain-control of a computer. This technology is named MindEx (for Mind Extender). It utilizes four implanted "chips" in the human brain from which investigators can record brain activity during subjects' thoughts and decode meaningful information from this activity to be used as control signals for a computer, a laptop, or a tablet. The use of four brain regions is a significant differentiating feature and scientific innovation of this study over much prior work in this space, that typically derived control signals from one, or sometimes two brain regions. The brain regions to be used here can allow the decode of multiple variables simultaneously, including not just moment-to-moment position, but also high-level goals, intentions, decisions, scene comprehension, and error-related signals involved in natural human behavior. The research is being done through a prospective, longitudinal, single-arm early feasibility study to examine the safety and effectiveness of using MindEx to provide the user an intuitive, efficient, and accurate ability to control multiple applications on a computer interface such as a word processor, a paint application, or to play simple video games. Such versatility could greatly improve the autonomy and quality of life of severely paralyzed individuals. Two subjects will be enrolled, each implanted with MindEx for a period of at least 53 weeks and up to 313 weeks. The study is expected to take at least one year and up to six years in total.
Přehled studie
Postavení
Podmínky
Intervence / Léčba
Typ studie
Zápis (Odhadovaný)
Fáze
- Nelze použít
Kontakty a umístění
Studijní kontakt
- Jméno: Nader Pouratian, MD, PhD
- Telefonní číslo: 214-645-5465
- E-mail: nader.pouratian@utsouthwestern.edu
Studijní záloha kontaktů
- Jméno: Olivia Gibble, MS
- Telefonní číslo: 214-648-8880
- E-mail: Olivia.gibble@utsouthwestern.edu
Studijní místa
-
-
Texas
-
Dallas, Texas, Spojené státy, 75390
- Nábor
- UT Southwestern Medical Center
-
Kontakt:
- Cecile Verbaarschot, MD, PhD
- Telefonní číslo: 2146483395
- E-mail: Cecile.Verbaarschot@UTSouthwestern.edu
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Paralysis resulting from cervical spinal cord injury (SCI), brainstem stroke (ischemic or hemorrhagic), or amyotrophic lateral sclerosis (ALS)
- Provide informed consent
- Understand and comply with instructions, if necessary, with the aid of a translator
- Communicate via speech or other means
- Surgical clearance
- Life expectancy greater than 12 months
- Travel to study locations up to five days per week for the duration of the study
- Caregiver monitor for surgical site complications and behavioral changes on a daily basis
- Psychosocial support system
- Stable ventilator status
Exclusion Criteria:
- Presence of memory problems
- Intellectual impairment
- Psychotic illness or chronic psychiatric disorder, including major depression if untreated
- Poor visual acuity
- Pregnancy
- Active infection or unexplained fever
- Scalp lesions or skin breakdown
- HIV or AIDS infection
- Active cancer or chemotherapy
- Diabetes
- Autonomic dysreflexia
- History of seizure
- Implanted hydrocephalus shunt
- Prior cranioplasty
- Other implanted devices
- Medical conditions contraindicating surgery and chronic implantation of a medical device
- Unable to undergo MRI or anticipated need for MRI during the study
- Breastfeeding an infant (direct nursing or via a bottle of expressed milk)
- Chronic oral or intravenous use of steroids or immunosuppressive therapy
- Suicidal ideation
- Drug or alcohol dependence
- Planning to become pregnant, or unwilling to use adequate birth control
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Proveditelnost zařízení
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: Mind Extender (MindEx)
MindEx consists of two Neuroport Multi-Port Arrays, described in detail in the intervention description. Each NeuroPort Multi-Port Array comprises two electrode arrays implanted into human brain tissue, for a total of four electrode arrays. These will be in 1) prefrontal cortex, a brain area involved in scene comprehension, action selection, and error signaling, 2) premotor cortex, a brain area involved in planning ongoing and upcoming actions, 3) posterior parietal cortex, a brain area involved in processing sensory-to-motor transformations during movements, and 4) primary motor cortex, responsible for controlling movement. The pair of electrode arrays in each NeuroPort Multi-Port Array connect to a single percutaneous pedestal attached to the skull during a surgical procedure. Following recovery from the surgical placement, subjects will participate in study sessions up to 5 times a week. They will learn to use thought to control applications on a computer, a laptop, or a tablet. |
NeuroPort Multi-Port Arrays allow for the local recording of cerebral cortex. The Mind Extender (MindEx) system is primarily composed of two NeuroPort Multi-Port Arrays. Each Multi-Port device consists of two arrays, each with 100 electrodes in a 10 x 10 configuration, with dimensions 4 mm x 4 mm x 1.5 mm (W x H x D), and a titanium percutaneous connector, 19 mm diameter at the base. Each MultiPort can have a total of 128 active channels (capable of transmitting neural signals to the percutaneous connector) across the two arrays. In our design, we will split active channels evenly between the two arrays resulting in 64 active channels per array. The four arrays of the two Multi-Port device will be implanted into prefrontal cortex, premotor cortex, primary motor cortex, and posterior parietal cortex. |
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Continuous trajectory decoding
Časové okno: Six years after array implantation
|
A primary objective of this study is to evaluate the effectiveness of the system in providing users the ability to continuously move a cursor on a tablet/computer. The hypothesis is that trajectory readability from neural signals will be significantly greater than the level of chance. Standardized tests will be used to test this objective, and performance will be compared to the level of chance. One example of a standardized test to be used is the accuracy of continuous trajectory decoding measured by the radial-8 assessment task. |
Six years after array implantation
|
|
Incidence of intervention-related adverse events
Časové okno: Six years after array implantation
|
Serious adverse events (SAE) will be evaluated against a 1% threshold level. We will use regular inspection of the subjects' scalps to assess for breakdown, discharge, or infection, and use history and physical exam to evaluate for new symptoms, and compare to baseline assessments. |
Six years after array implantation
|
|
Competency in computer/tablet control
Časové okno: Six years after array implantation
|
An underlying hypothesis in this study is that the system will enable users the ability to control a computer/tablet interface by selecting icons. An underlying hypothesis in the study is that neural signals will enable decoding the chosen target at higher accuracy than the level of chance. Standardized tests will be used to test this objective, and performance will be compared to the level of chance. An example of a standardized test to be used is the brain-control for tablet test (BCTT) which grades the accuracy of target selection by mental fixation to the level of chance. |
Six years after array implantation
|
|
Efficacy of multiple brain regions for neural control over subsets of brain regions
Časové okno: Six years after array implantation
|
An objective of this study is to determine whether the combination of neural signals from multiple brain regions in brain-computer interface control is more advantageous than from a subset of the brain regions being tested. The hypothesis is that because the four brain regions being implanted each encode different cognitive functions, their integration will be more useful to brain-computer interface control, than any subset of these regions. This objective will be tested by standardized tests (such as those mentioned for "Competency in computer/tablet control" and "Continuous trajectory decoding") in different groups of brain regions and reported for each, such as:
|
Six years after array implantation
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Change in quality of life
Časové okno: Time Frame: Annually, for six years
|
The functional change in quality of life will be evaluated through a Quality-of-Life Inventory (QOLI) administered periodically throughout the study. This is a 32-item questionnaire with a score range from 1-77, with higher scores reflecting higher satisfaction. |
Time Frame: Annually, for six years
|
Spolupracovníci a vyšetřovatelé
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
- Neurologické projevy
- Cerebrovaskulární poruchy
- Onemocnění mozku
- Onemocnění centrálního nervového systému
- Nemoci nervového systému
- Cévní onemocnění
- Kardiovaskulární choroby
- Rány a zranění
- Patologické procesy
- Neuromuskulární onemocnění
- Metabolické choroby
- Infarkt mozku
- Ischemie mozku
- Infarkt
- Nekróza
- Neurodegenerativní onemocnění
- Trauma, nervový systém
- Nemoci míchy
- Proteinopatie TDP-43
- Nedostatky proteostázy
- Ischemie
- Nemoc motorických neuronů
- Mrtvice
- Patologické stavy, příznaky a symptomy
- Nutriční a metabolické nemoci
- Příznaky a symptomy
- Amyotrofní laterální skleróza
- Poranění míchy
- Ochrnutí
- Kvadruplegie
- Infarkt mozkového kmene
Další identifikační čísla studie
- STU-2023-0306
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
Investigators with established research programs will be eligible for data sharing. Interested investigators will be required to submit a summary of the proposed work and requested data elements. If approved by the Principal Investigator of the study, data will be shared. This data will be de-identified and coded. There is no plan to share identifiers outside the study team.
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .