Impact of a Motion Correction Algorithm on Image Quality and Diagnostic Utility in Patients Undergoing CT Angiography: A Randomized Controlled Trial

The aim of this study was to investigate the effect of a new motion correction algorithm on image quality and diagnostic utility in unselected patients undergoing coronary cardiac computed tomography, and to investigate if this motion correction algorithm can compensate for the usual use of intravenously medication (beta-blockers) before the scan.

Studieoversigt

Status

Afsluttet

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

Aims:

To investigate the motion correction algorithm Snapshot-Freeze(SSF) compared to standard reconstruction(STD) in patients randomized to receive beta-blockers(BB) or no beta-blockers(non-BB) before coronary CT angiography (CCTA), and to investigate if SSF can replace BB.

Methods:

The study included 140 consecutively recruited patients scheduled to CCTA to rule out coronary artery disease.

The inclusion criteria were: age ≥ 18 years, Glomerular filtration rate ≥ 60 mL/min, Heart Rate between 60 and 85 bpm before the scan. The exclusion criteria were: irregular heart rhythm or history of allergic reaction to contrast agents. Patients were randomized to the BB group or the non-BB group. The trial complied with the Declaration of Helsinki and was approved by the local ethics committee. Written informed consent was obtained from all patients.

Image quality score:

The evaluation was performed according to the Likert score as follows: 1: excellent, no motion artifacts, clear delineation of the segments; 2: good, minor artifacts, mild blurring of the segment; 3: adequate, moderate artifacts, moderate blurring without structure discontinuity; and 4: poor and non-diagnostic, with doubling or discontinuity in the course of the segments, preventing evaluation or producing vessel structures that were not differentiable. In cases where the image quality was less than excellent (Likert score 2-4), the readers noted the reason(s) for the observed artifact.

Statistical analyses:

Quantitative variables were expressed as mean ± standard deviation, and categorical values as frequencies or percentages. Values from the Likert score were dichotomized to excellent vs. non-excellent (Likert score 1 vs. 2-4), and diagnostic vs. non-diagnostic (Likert score 1-3 vs. 4). McNemar's test was performed to test categorical variables separately per-vessel and per-patient level. Analyses for all segments were calculated by the Wilcoxon signed-rank test.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

140

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Svendborg, Danmark, 5700
        • Department of Medical Research, OUH, Svendborg

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • age ≥ 18 years,
  • glomerular filtration rate ≥ 60 mL/min,
  • heart rate between 60 and 85 bpm before the scan

Exclusion Criteria:

  • irregular heart rhythm
  • history of allergic reaction to contrast agents

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Ingen indgriben: seloken
In "seloken" arm, patients performs the cardiac CT procedure regarding the national scan guidelines, ande receive 5-10 intravenous seloken, until heart rate below 60 beats pr minit is achieved.
Eksperimentel: non-seloken
Patients randomized to "non-seloken", do not receive any medication.
regarding the guidelines patients receive seloken before the cardiac CT scan to lower the heart rate during the scan. The intervention in this study is to avoid the medication with seloken before the scan, and to investigate if the use of a new motion correction scan algorithm can compensate for the absence of the seloken.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
images with non diagnostic image quality
Tidsramme: up to 1 year
number of non diagnostic images.
up to 1 year

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
images with Excellent image quality
Tidsramme: up to 1 year
number of presented images with "Excellent" image quality
up to 1 year
motion artifacts
Tidsramme: up to 1 year
number of presented motion artifacts
up to 1 year

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Studieleder: jess Lambrechtsen, MD, Odense University Hospital

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. januar 2013

Primær færdiggørelse (Faktiske)

1. januar 2014

Studieafslutning (Faktiske)

1. august 2015

Datoer for studieregistrering

Først indsendt

18. november 2015

Først indsendt, der opfyldte QC-kriterier

26. november 2015

Først opslået (Skøn)

1. december 2015

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

4. december 2015

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

3. december 2015

Sidst verificeret

1. november 2015

Mere information

Begreber relateret til denne undersøgelse

Yderligere relevante MeSH-vilkår

Andre undersøgelses-id-numre

  • Snapshot Freeze

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Hjertesygdomme

Kliniske forsøg med non-seloken

3
Abonner