- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT06782295
L'uso di CCK vs PS nei TKA di revisione
Uno studio prospettico randomizzato e controllato che mette a confronto le articolazioni condilari vincolate e quelle posteriori stabilizzate nell'artroplastica totale del ginocchio di revisione
This study aims to compare the clinical impact of Constrained Condylar versus Posterior Stabilized Knee (PS) bearings on patient satisfaction and surgical outcomes including mid-term survivorship among patients undergoing revision total knee arthroplasty.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
The primary purpose of this study is to determine whether a difference exists in clinical patient reported outcomes between CCK or PS bearings following rTKA. A secondary goal of the study is to compare both bearings in survivorship free of revision surgery as well as other surgical complications including instability, in early to mid-term follow-up.
Tipo di studio
Iscrizione (Stimato)
Fase
- Fase 4
Contatti e Sedi
Contatto studio
- Nome: Anne DeBenedetti, MSc
- Numero di telefono: 312-432-2468
- Email: anne.debenedetti@rushortho.com
Backup dei contatti dello studio
- Nome: Omary Behery, MD
- Numero di telefono: 630-339-2230
- Email: omar.behery@rushortho.com
Luoghi di studio
-
-
Illinois
-
Chicago, Illinois, Stati Uniti, 60612
- Reclutamento
- Rush University Medical Center
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion criteria:
- Patients between 18-80 years of age
- Patients who are undergoing both femoral and tibial component revisions, or isolated femoral component revisions with a retained tibial component that is compatible with PS or CCK bearings
- Patients who are at least 6-weeks out from primary TKA surgery, with complete pre-operative and post-operative knee radiographs obtained at standard of care perioperative visits (AP/lateral and patellar views)
- Patients undergoing rTKA for indications including aseptic component loosening, flexion or extension coronal or sagittal instability, component malalignment, arthrofibrosis, patellar maltracking, reimplantation following single or two-stage exchange revision for prosthetic joint infection or bearing surface wear when femoral or tibial component revision is indicated.
- The use of revision total knee arthroplasty systems which have PS and CCK bearing options including different degree options of coronal and rotational constraint (to be individually randomized per constrained option):
- Zimmer Biomet Persona, NexGen, or Vanguard
- Smith and Nephew Legion
- DJO / Enovis Empowr
- Stryker Triathlon
- Link SymphoKnee
- Depuy Attune sion Criteria:
Exclusion Criteria:
Patients undergoing rTKA with a hinged implant, or pre-operatively determined to require CCK bearing rTKA, > 80 years of age, or those requiring rTKA less than 6-weeks from the primary TKA,
Patients undergoing rTKA for bearing exchange only rTKA, isolated tibial component rTKA
Patients with pre-operative diagnosis of extensor mechanism disruption or collateral ligament incompetence or with a compromised soft tissue envelope requiring pre-pre-operative plastic surgery evaluation and planned soft tissue coverage.
-
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Comparatore attivo: Constrained condylar (CCK)
Once patient meets inclusion criteria, they'll be randomized prior to surgery to a specific CCK implant design. All surgeries will be done at the approved hospital or ASC and if the allocated component isn't used, the patient will still be followed post operatively and remain in the study. |
Patients in this intervention will receive a CCK bearing component
Altri nomi:
|
|
Comparatore attivo: Posterior Stabilized (PS) bearing
Once patient meets inclusion criteria, they'll be randomized prior to surgery to a specific PS implant design. All surgeries will be done at the approved hospital or ASC and if the allocated component isn't used, the patient will still be followed post operatively and remain in the study. |
Patients in this intervention will receive a PS bearing component |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Clinical patient reported outcomes
Lasso di tempo: 6 weeks post op
|
patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time. The clinical patient reported outcomes of a revision total knee replacement to detect a 6-point difference in knee society score (KSS) |
6 weeks post op
|
|
Clinical patient reported outcomes
Lasso di tempo: 1 year post op
|
Patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time. The clinical patient reported outcomes of a revision total knee replacement to detect a 6-point difference in knee society score (KSS) |
1 year post op
|
|
Clinical patient reported outcomes
Lasso di tempo: 2 year post op
|
Patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time. The clinical patient reported outcomes of a revision total knee replacement to detect a 6-point difference in knee society score (KSS) |
2 year post op
|
|
Clinical patient reported outcomes
Lasso di tempo: 5 year post op
|
Patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time. The clinical patient reported outcomes of a revision total knee replacement to detect a 6-point difference in knee society score (KSS) |
5 year post op
|
|
Clinical patient reported outcomes
Lasso di tempo: 10 year post op
|
Patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time. The clinical patient reported outcomes of a revision total knee replacement to detect a 6-point difference in knee society score (KSS) |
10 year post op
|
|
Clinical patient reported outcomes
Lasso di tempo: 20 year post op
|
Patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time. The clinical patient reported outcomes of a revision total knee replacement to detect a 6-point difference in knee society score (KSS) |
20 year post op
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Clinical reported outcomes (Koos Jr)
Lasso di tempo: 6 weeks to 20 years post op
|
patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time |
6 weeks to 20 years post op
|
|
Range of motion over time
Lasso di tempo: pre op to 20 years pots op
|
Patients will have their knee range of motion (ROM) checked prior to revision surgery and at multiple timepoints after surgery |
pre op to 20 years pots op
|
|
Clinical reported outcomes ( VR-12)
Lasso di tempo: 6 weeks, 1 year, 2 years, 5 years, 10 years, 15 years, 20 years post op
|
patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time |
6 weeks, 1 year, 2 years, 5 years, 10 years, 15 years, 20 years post op
|
|
Clinical reported outcomes ( Forgotten Joint Score)
Lasso di tempo: 6 weeks to 20 years post op
|
patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time |
6 weeks to 20 years post op
|
|
Clinical reported outcomes (EQ-5D-3L)
Lasso di tempo: 6 weeks, 1 year, 2 years, 5 years, 10 years, 15 years, 20 years post op
|
patients will be asked pre and post operatively to completed standard of care patient reported outcomes to compare over time |
6 weeks, 1 year, 2 years, 5 years, 10 years, 15 years, 20 years post op
|
Collaboratori e investigatori
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- 25010208
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .