- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT06630702
Applicazione della SCS epidurale toracica per la gestione del FOG nei pazienti con malattia di Parkinson in fase avanzata
Applicazione della stimolazione epidurale toracica del midollo spinale (SCS) per la gestione del congelamento dell'andatura (FOG) in pazienti con malattia di Parkinson in stadio avanzato
Spinal cord stimulation (SCS) has proven to be effective for pain that is unresponsive to medication. This technique involves an anesthesiologist or a neurosurgeon placing stimulation electrodes at the thoracic vertebrae to provide pain relief. Although SCS is not currently a standard treatment for patients with Parkinson's disease, recent studies have shown that Parkinson's patients who experience intolerable pain and undergo SCS treatment not only experience pain relief but also show improvements in gait and other Parkinson's symptoms. Therefore, the investigators aim to use temporary, minimally invasive SCS electrodes to help patients with nrFOG (non-responsive Freezing of Gait) improve their stability and reduce their risk of falls.
Panoramica dello studio
Stato
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
- Nome: Kai-Hsiang Chen, M.D.
- Numero di telefono: 522610 +886-3-5326151
- Email: stanleychen1230@gmail.com
Luoghi di studio
-
-
Hsinchu City
-
Hsinchu, Hsinchu City, Taiwan, 300
- Reclutamento
- National Taiwan University Hospital Hsin-Chu Branch
-
Contatto:
- Kai-Hsiang Chen, M.D.
- Numero di telefono: 522610 +886-3-5326151
- Email: stanleychen1230@gmail.com
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Age:40-85 years old.
- Patients with primary Parkinson's disease who have been diagnosed by a movement disorder specialist for more than 5 years. Although they have a clear response to drugs, they have a frozen gait that cannot be controlled by drugs. Lower limb pain may be present with or without Parkinson's non-motor symptoms.
- No other secondary gait problems.
Exclusion Criteria:
- Atypical Parkinson's disease.
- Patients with spinal cord injuries.
- Medication-controlled frozen gait.
- It is expected that there are lesions near the implantation area causing spinal canal stenosis or myelopathy (can be ruled out by MRI).
- It is expected that the implantation area has undergone previous surgery or there is infection near the implantation area, which may affect the success rate of implantation or increase concerns about complications (such as severe extraspinal adhesion, or spinal cord damage in previous surgeries).
- People with abnormal coagulation function (such as hemophilia patients) or those who have been controlled by long-term use of antithrombotic drugs and cannot stop taking them in a short period of time.
- CDR (Clinical Dementia Rating Scale) ≧2. 8. Those who are allergic to developer.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Impianto SCS
|
300Hz/300us 130Hz/300us 60Hz/300us |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Gait parameters --- foot rotation [degtree]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- step length [cm]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- stride length [cm]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- step width [cm]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- stance phase [%]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- swing phase [%]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- double stance phase [%]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- step time [second]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- stride time [second]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- cadence [steps/minute]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Gait parameters --- velocity [km/hour]
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
(1)Measured by plantar pressure distribution measurement systems (100 Hz, FDM-T, Zebris Medical GmbH, Germany) with a maximum gait track of 6 meters. |
Day 0, Day 2, Day 3, Day 4, and Day 7
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Clinical Scale
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Clinical score
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Clinical Scale
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Clinical Scale
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Clinical Scale
Lasso di tempo: Day 0, Day 2, Day 3, Day 4, and Day 7
|
|
Day 0, Day 2, Day 3, Day 4, and Day 7
|
Collaboratori e investigatori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 202307093DINC
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .