- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07289802
Segurança e Eficácia da Malha Anatómica 3DMax™ MID (BD, EUA) na Reparação Laparoscópica-endoscópica de Hérnia Inguinal - Estudo Observacional Prospectivo Multicêntrico (3DMS)
Segurança e Eficácia da Malha Anatómica 3DMax MID (BD, EUA) na Reparação Laparoendoscópica de Hérnia Inguinal: Um Estudo de Coorte Observacional Prospetivo Multicêntrico
This is a multicenter, prospective, observational cohort study evaluating the safety and efficacy of the 3DMax MID Anatomical Mesh (BD, USA) in laparoendoscopic inguinal hernia repair. Adult patients undergoing elective transabdominal preperitoneal (TAPP) or totally extraperitoneal (TEP) repair will be enrolled and followed according to routine clinical practice.
The primary objective is to assess the inguinal hernia recurrence rate within 12 months after surgery. Secondary objectives include evaluation of postoperative pain, groin discomfort and foreign body sensation, as well as early and late postoperative complications.
All participating patients will receive the 3DMax MID Anatomical Mesh as part of standard care. No additional experimental procedures are planned. Clinical data will be collected at baseline and during predefined follow-up contacts (early postoperative period, 1 month, 3 months and 12 months) using standardized forms and patient interviews.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Laparoendoscopic techniques such as transabdominal preperitoneal (TAPP) and totally extraperitoneal (TEP) repair are widely used for the treatment of inguinal hernia and are associated with faster recovery and lower rates of chronic pain compared with open repair in appropriately selected patients. Mesh reinforcement is a key component of these procedures. Three-dimensional, anatomically contoured meshes have been developed to improve conformability to the myopectineal orifice and to provide stable coverage of the inguinal region, potentially reducing the need for additional fixation and lowering the risk of chronic postoperative pain.
The 3DMax MID Anatomical Mesh (BD, USA) is a medium-weight, macroporous, pre-shaped polypropylene mesh designed specifically for inguinal hernia repair. Its three-dimensional configuration and recoil properties are intended to facilitate correct positioning and stable coverage of the inguinal anatomy during laparoendoscopic procedures.
This multicenter, prospective, observational cohort study will include consecutive adult patients undergoing elective TAPP or TEP inguinal hernia repair in participating centers, in whom the operating surgeon has decided to use the 3DMax MID Anatomical Mesh as part of routine practice. No randomization or control group is planned, and no interventions outside standard care will be performed.
Data will be collected from medical records and structured follow-up contacts (early postoperative check, approximately 30 days, 3 months and 12 months after surgery). The primary endpoint is hernia recurrence within 12 months. Secondary endpoints include postoperative pain, groin discomfort, foreign body sensation and early or late postoperative complications. Study data will be recorded in a standardized database and analyzed descriptively to characterize the safety profile and clinical performance of the 3DMax MID Anatomical Mesh in real-world practice.
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Locais de estudo
-
-
-
Gdansk, Polônia, 80-280
- Swissmed Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Adult patients with primary unilateral or bilateral inguinal hernia undergoing elective laparoendoscopic (TAPP or TEP) repair with implantation of the 3DMax MID Anatomical Mesh in participating centers.
Descrição
Inclusion Criteria:
- Age 18 years or older
- Primary unilateral or bilateral inguinal hernia
- Scheduled for elective laparoendoscopic inguinal hernia repair (TAPP or TEP)
- Considered suitable for general anesthesia and laparoendoscopic approach by the treating surgeon
- 3DMax MID Anatomical Mesh planned for use as part of routine clinical care
- Ability and willingness to provide written informed consent
Exclusion Criteria:
- Age below 18 years
- Emergency surgery (e.g. incarcerated or strangulated hernia requiring urgent intervention)
- Contaminated or potentially contaminated surgical field
- Recurrent inguinal hernia in the same groin (previous repair with mesh or suture)
- Concomitant procedures or clinical situations in which the surgeon decides that a different mesh concept or technique is required
- Inability or unwillingness to comply with follow-up schedule (e.g. lack of telephone contact, severe cognitive impairment)
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: COHORT
- Perspectivas de Tempo: PROSPECTIVE
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
3DMax MID TAPP/TEP
Adult patients undergoing elective laparoendoscopic inguinal hernia repair (TAPP or TEP) with implantation of the 3DMax MID Anatomical Mesh (BD, USA) as part of routine clinical practice. No randomization or control group is used; all enrolled participants receive the same type of mesh according to the treating surgeon's standard technique. |
Implantation of a pre-shaped, medium-weight, macroporous polypropylene anatomical mesh (3DMax MID Anatomical Mesh, BD, USA) during elective laparoendoscopic inguinal hernia repair (TAPP or TEP) as part of routine clinical practice. No additional experimental procedures beyond standard surgical care are planned.
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Inguinal hernia recurrence rate at 12 months
Prazo: 12 months after index surgery
|
Proportion of patients with clinically and/or imaging-confirmed inguinal hernia recurrence within 12 months after the index laparoendoscopic repair with 3DMax MID Anatomical Mesh. |
12 months after index surgery
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Postoperative pain intensity (VAS 0-10)
Prazo: 7-10 days, 30 days, 3 months and 12 months after surgery
|
Postoperative pain intensity assessed using a 0-10 Visual Analog Scale (VAS) during early and late follow-up. Chronic pain will be defined as VAS ≥4 persisting beyond 3 months after surgery. |
7-10 days, 30 days, 3 months and 12 months after surgery
|
|
Early postoperative complications (≤30 days)
Prazo: Up to 30 days after surgery
|
Incidence of early postoperative complications within 30 days after surgery, including wound infection, hematoma, seroma, urinary retention, bleeding, and other mesh- or procedure-related adverse events. |
Up to 30 days after surgery
|
|
Late postoperative complications (>30 days to 12 months)
Prazo: From >30 days to 12 months after surgery
|
Incidence of late postoperative complications occurring between 30 days and 6 months after surgery, including chronic groin pain, mesh-related complications, and reoperations in the operated groin. |
From >30 days to 12 months after surgery
|
|
Groin discomfort and foreign body sensation
Prazo: 7-10 days, 30 days, 3 months and 12 months after surgery
|
Patient-reported groin discomfort, stiffness and foreign body sensation in the operated region, assessed using standardized questions or Likert-type scales (0-10) during follow-up contacts. |
7-10 days, 30 days, 3 months and 12 months after surgery
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Cadeira de estudo: Maciej Śmietański, Prof., LUX MED Hospital in Gdańsk
- Investigador principal: Mateusz Zamkowski, MD, PhD, LUX MED Hospital in Gdańsk
Publicações e links úteis
Publicações Gerais
- Zamkowski M, Tomaszewska A, Lubowiecka I, Karbowski K, Smietanski M. Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study. Surg Endosc. 2023 Mar;37(3):1781-1788. doi: 10.1007/s00464-022-09699-5. Epub 2022 Oct 13.
- Zamkowski M, S Mietanski M, Franczak P, Gorski D, Grabias J, Janik M, Krol A, Mitura K, Medras O, Nawacki L, Romanczuk M, Rymkiewicz P, Saluk S, Sroczynski P, Sulkowski L, Wieczorek D, Wlodarczyk M. MEsh FIxation STudy in Laparoendoscopic Repair of M3 Inguinal Hernias: Multicenter, Double-blind, Randomized Controlled Trial-MEFISTO Trial. Ann Surg. 2025 Jun 1;281(6):921-927. doi: 10.1097/SLA.0000000000006669. Epub 2025 Feb 13.
- Zamkowski M, Smietanski M. MEsh FIxation in Laparoendsocopic Repair of Large M3 inguinal hernias: multicenter, double-blinded, randomized controlled trial-study protocol for a MEFI Trial. Trials. 2023 Sep 5;24(1):572. doi: 10.1186/s13063-023-07601-9.
- Zamkowski M, Tomaszewska A, Lubowiecka I, Karbowski K, Putko M, Smietanski M. Mechanical stability of new-generation meshes for M3 inguinal hernia repair: experimental pressure chamber testing of SWING-Mesh and 3DMax MID Anatomical Mesh. Wideochir Inne Tech Maloinwazyjne. 2025 Oct 29;20(4):409-414. doi: 10.20452/wiitm.2025.17990. eCollection 2025 Dec 29.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 3DMID-PL
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .