Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Clinical Trial on the Effect of REGENETEN Bioinductive Implant in the Supraspinatus Tendon Repair

This study aims a determine the effect that the addition of REGENETEN Bioinductive Implant has on Supraspinatus Tendon Repair. 120 patients will be included in this prospective, randomized, parallel group study.

Aperçu de l'étude

Statut

Actif, ne recrute pas

Les conditions

Description détaillée

The rotator cuff tear is one of the most frequent pathologies in the shoulder joint. When there are many symptoms these breaks are repaired surgically. The success rate of healing of these injuries is between 30% and 80%. In two recent studies conducted at two of the centers participating in this trial, the success rate of repair was 75% (unpublished data) and 70% respectively.

The use of high porosity resorbable bovine collagen meshes as bioinductive scaffolds for cuff repair seems to be a valid alternative when trying to improve the success rate in the healing of rotator cuff injuries.

REGENETEN Bioinductive Implant (a high porosity reconstituted type I collagen mesh of bovine origin) is applied to the repaired tendon. In a pilot study of 9 subjects with full thickness supraspinatus ruptures who underwent tendon repair and subsequently had the implant associated with the rupture, a significant clinical improvement was observed after one year and was observed on magnetic resonance imaging ( RM) 100% healing of breaks. In a study of 33 subjects with partial thickness tears treated with the implant alone, improvement in MRI characteristics of the tendon was observed in 31 cases. There is a study that performs a histological analysis of samples obtained in 7 subjects in whom the implant was used. No evidence of foreign body reaction or inflammatory reaction was observed. In none of the three studies where said implant was used in humans were any complications or adverse effects related to the use of said implant observed.

The objective of the study is to evaluate the effect that the addition of REGENETEN bovine collagen mesh has on tendon repair on MRI performed one year after surgery.

The study does not in itself pose a greater risk than the usual practice for the patient, since in these subjects where the implant could be used as a supplement to the repair, having already obtained the CE marking.

Type d'étude

Interventionnel

Inscription (Réel)

124

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Madrid
      • Madrid, Madrid, Espagne, 28034
        • Hospital Ramón y Cajal

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Patients who, after having received information about the design, the purposes of the study, the possible risks that may arise from it, and who may at any time deny their collaboration, give their written consent to participate in the study.

  • >18 years

  • Patients who present:

    • Symptomatic ruptures of the supraspinatus muscle (SE) with or without involvement of the infraspinatus (IE) with anteroposterior size of the rupture of 1 to 4 cm.
    • With less than 3cm of retraction,
    • With the absence of severe muscular atrophy confirmed by magnetic resonance imaging or CT (Absence of Goutalier grade I or II atrophy in muscle mass). MRI or CT must have been performed at most 6 months before the intervention.
    • That it be confirmed during the exploratory arthroscopy at the beginning of the intervention.
    • That after repair a coverage of the native footprint of the tendon of at least 80% is obtained
  • No presence of rupture that requires repair in the tendons of the subscapularis muscles or minor round

  • Understand the purpose of the study and be available for regular hospital visits.

  • Negative urine pregnancy test performed in the 7 days prior to the start of study treatment in premenopausal women or <2 years after menopause

Exclusion Criteria:

  • Pregnancy or planning to become pregnant during the course of the study.
  • SE tendon tears of more than 3cm retraction
  • Tendon ruptures of the SE and IE muscles with anteroposterior size of the rupture greater than 4 cm.
  • SE and / or IE tendon ruptures that are considered irreparable or only partially repairable at the time of the intervention
  • Presence of ruptures of the subscapularis and / or minor round tendons
  • Presence of grade III or IV Goutallier atrophy in the supraspinatus muscle mass
  • History of other orthopedic pathologies in the affected shoulder (previous shoulder surgeries, fractures, tendon re-ruptures of the supraspinatus or other tendons, rheumatic diseases, septic arthritis, ...)

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Tripler

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: REGENETEN Bioinductive Implant

REGENETEN bioinductive Implant,a bovine mesh that will be implanted following supraspinatus tendon repair.

REGENETEN bioinductive Implant,a reconstituted bovine origin type I collagen mesh with a proprietary high porosity system that is commercialized sterile, dehydrated and desiccated in two sizes (20x26mm and 25x31mm). It will be implanted following supraspinatus tendon repair.

Aucune intervention: Standard of Care

Supraspinatus tendon repair.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Integrity of the tendon repaired in an MRI study one year after the intervention using the Sugaya classification (Sugaya H (2005)).
Délai: 12 months

This is a classification system described by Sugaya et al. which uses magnetic resonance imaging in order to evaluate tendon integrity after rotator cuff repair. Postoperative cuff integrity is classified into 5 categories: type I, sufficient thickness with homogenously low intensity; type II, sufficient thickness with partial high intensity; type III, insufficient thickness without discontinuity; type IV, presence of minor discontinuity; type V, presence of major discontinuity

12 months

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Change in pain levels. Measured with questions 3 to 6 of the Brief Pain Inventory.
Délai: 3 months, 6 months and 12 months after surgery

This item has a scale of 0 to 10 with 0 indicating "No pain" and 10 indicating "Pain as bad as you can imagine"

3 months, 6 months and 12 months after surgery
Functional changes, measured with the Constant-Murley Scale.
Délai: 3 months, 6 months and 12 months after surgery.

The Constant-Murley Shoulder Score is a scoring method used by clinicians to assess function of the shoulder. The score is on a scale of 0 to 100, with 0 being no shoulder function and 100 being excellent function.

3 months, 6 months and 12 months after surgery.
Functional changes, measured with ASES questionnaire.
Délai: 3 months, 6 months and 12 months after surgery.

The American Shoulder and Elbow Surgeons (ASES) questionnaire was developed to provide a standardized method for evaluating shoulder function and has been validated in patients with any array of shoulder pathologies. The range is from 0 to 100, with 0 being worst, and 100 being best.

3 months, 6 months and 12 months after surgery.
Changes in quality of life measured with EQ-5D-5L questionnaire.
Délai: 3 months, 6 months and 12 months after surgery.

The Euro Quality of Life Five Dimensions 5 Level (EQ-5D-5L) questionnaire consists of two parts: a descriptive system and a Visual Analogue Scale.

The descriptive system describes the health state and consists of five dimensions: mobility, self-care, usual activities, pain/discomfort, and anxiety/depression. Patients who reported problems were then categorized into two categories, a "has no problem" category (health state code of 1) and "has problem" category (health state code of 2-5) for each level of each dimension.

The second part of the EQ-5D-5L questionnaire is the EQ-VAS, which is a thermometer-like scale (ranging from 0 to 100) that reflects the patient's health in general. EQ-VAS represents the patient perspective, where 0 indicates the worst imaginable health state and 100 reflects the best imaginable health state.

3 months, 6 months and 12 months after surgery.
Number of patients with complications in both arms
Délai: 12 months

Rate of complications, including: infection, implant intolerance, readmission, reoperation, or fracture.

12 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Miguel Angel Ruiz Iban, MD, PhD, Hospital Ramón y Cajal, Spain

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

17 juin 2020

Achèvement primaire (Estimé)

20 mars 2027

Achèvement de l'étude (Estimé)

20 mars 2027

Dates d'inscription aux études

Première soumission

17 juin 2020

Première soumission répondant aux critères de contrôle qualité

22 juin 2020

Première publication (Réel)

23 juin 2020

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

5 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

4 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • MALLAMANGUITO

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner