Impact of Vascular Reparative Therapy on Vasomotor Function and Myocardial Perfusion:a Randomized H215O PET/CT Study (VANISH)

2016년 7월 30일 업데이트: Wynand Stuijfzand, Amsterdam UMC, location VUmc

Impact of Vascular Reparative Therapy on Vasomotor Function and Myocardial Perfusion: a Randomized H215O PET/CT Study

The purpose of this study is to examine the improvement of myocardial blood flow induced by regained vasomotor functions of the stented coronary segment after resorption of BVS over time.

연구 개요

상세 설명

Objective The objective of the proposed study is to determine the impact of VRT, in comparison with conventional drug-eluting stenting, on endothelium dependent vasodilation and maximal hyperemic myocardial perfusion using H215O PET.

Study design The study is designed as a single center single-blind randomized clinical trial and will be conducted at the VU University Medical Center in Amsterdam.

Summary of the study design It is hypothesized that VRT will result in augmented endothelium dependent coronary vasodilation and maximal myocardial perfusion as compared with conventional stenting of a coronary lesion. Within one year sixty patients (age 18-65) with documented single vessel CAD (type A or B1 lesion) accepted for PCI based on clinical grounds and according to current international guidelines, will be asked to participate in this trial. Patients will be randomized to implantation of a drug-eluted stent (Xience Prime) or BRS (Absorb). The patients will be blinded to the nature of the implanted device. H2 15O PET will be performed one month (reference scan), one year, and three years after the PCI procedure (resolution of BRS is generally complete within a three year period). The PET protocol will consist of three MBF measurements: resting MBF, during endothelial dependent vasodilation provoked by coldpressor-testing (CPT), and during (endothelial dependent and independent) maximal vasodilation by infusion of adenosine intravenously. After three years a control invasive coronary angiogram will document any potential obstructive coronary lesions that may affect the MBF measurements.

Primary study parameters/outcome of the study MBF measurements: resting MBF, during endothelial dependent vasodilation provoked by cold-pressor-testing (CPT), and during (endothelial dependent and independent) maximal vasodilation by infusion of adenosine intravenously

Secondary study parameters/outcome of the study Obstructive coronary lesions on control invasive coronary angiogram that may affect the MBF measurements.

연구 유형

중재적

등록 (실제)

60

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Noord-Holland
      • Amsterdam, Noord-Holland, 네덜란드, 1081 HV
        • VU University Medical Center

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Patients with documented obstructive CAD by invasive coronary angiography resulting in myocardial ischemia (either documented by invasive (i.e. fractional flow reserve, FFR) or noninvasive imaging techniques (e.g. exercise ECG, myocardial perfusion imaging, or inducibility of wall motion abnormalities during dobutamine stress).
  • Presence of a single, de-novo lesion in a native coronary artery (type A or B1), with a reference vessel diameter of at least 3.0 mm and a diameter stenosis of 50% or more and less than 100%, with a thrombolysis in myocardial infarction (TIMI) flow grade of at least 2. Coronary lesion must be amendable for successful treatment with one of the following BRS device dimensions: length 18 or 28 mm, diameter 3.0 or 3.5 mm.

Exclusion Criteria:

  • age of 65 or above
  • refusal or inability to provide written informed consent
  • other than single CAD
  • abnormal echocardiographic findings (i.e. wall motion abnormalities, ventricular hypertrophy, valvular disease etc.)
  • complex coronary lesion characteristics (e.g. lesions located in the left main coronary artery, lesions involving a side branch more than 2 mm in diameter, and the presence of thrombus or another clinically significant stenosis in the target vessel)
  • poor kidney function defined as an eGFR < 30 ml/min
  • astma or chronic obstructive pulmonary disease
  • other than sinus rhythm
  • pregnancy
  • bail out stenting after placement of the study device

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 하나의

무기와 개입

참가자 그룹 / 팔
개입 / 치료
활성 비교기: Bioresorbable vascular scaffold
Paritcipants will receive a bioresorbable vascular scaffols (BVS)
Drug eluting coronary stent, resorbable in 2-3 years
활성 비교기: Xience Prime
Participant will receive a Xience Prime stent
Drug eluting metallic stent

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Evaluation of Myocardial Blood Flow over time
기간: Three years
Endothelial dependent vasomotor function and effect on myocardial perfusion
Three years

2차 결과 측정

결과 측정
측정값 설명
기간
Restenosis
기간: Three years
Obstructive coronary lesions and lumen dimensions on control invasive coronary angiogram that may affect the MBF measurements
Three years

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Paul Knaapen, MD, PhD, Amsterdam UMC, location VUmc

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작

2013년 6월 1일

기본 완료 (예상)

2018년 6월 1일

연구 등록 날짜

최초 제출

2013년 6월 10일

QC 기준을 충족하는 최초 제출

2013년 6월 10일

처음 게시됨 (추정)

2013년 6월 12일

연구 기록 업데이트

마지막 업데이트 게시됨 (추정)

2016년 8월 2일

QC 기준을 충족하는 마지막 업데이트 제출

2016년 7월 30일

마지막으로 확인됨

2016년 7월 1일

추가 정보

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

관상동맥 질환에 대한 임상 시험

Bioresorbable vascular scaffold에 대한 임상 시험

3
구독하다