Porównanie dwóch urządzeń do zabezpieczenia dróg oddechowych (I-Gel i Air-Q) u dzieci w wieku 1-10 lat podczas znieczulenia ogólnego
Wpływ masek krtaniowych I-gel i Air-Q SP na ciśnienie przecieku gardłowo-językowego i wzdęcie żołądka u dzieci: randomizowane badanie z ultrasonografią
This study aims to compare two commonly used airway devices (I-gel and Air-Q) in children aged 1-10 years undergoing general anesthesia for surgery. These devices help doctors keep the airway open and support breathing during the operation. The study will evaluate how well each device works, how easy they are to place, and whether they cause air to enter the stomach. Ultrasound will be used to safely check the position of the device and detect any air in the stomach. The results of this study may help improve the safety and effectiveness of airway management in children during anesthesia.
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
This study is designed to compare two commonly used airway devices, I-gel and Air-Q, in children aged 1-10 years who are undergoing surgery under general anesthesia. These devices are used by anesthesiologists to keep the airway open and allow safe breathing during the procedure. Although both devices are widely used in clinical practice, their performance and safety in children may differ.
In this study, children will be randomly assigned to receive one of the two devices during anesthesia. The researchers will measure how effectively each device seals the airway, how easy and quick it is to place, and whether it causes air to enter the stomach, which can be an unwanted effect. Ultrasound imaging, a safe and non-invasive method, will be used to assess both the position of the device and the presence of air in the stomach.
All procedures performed in this study are part of standard clinical care, and no additional risks beyond routine anesthesia practice are expected. The information obtained from this study may help doctors choose the most effective and safest airway device for children, thereby improving the quality of anesthesia care and reducing potential complications.
Typ studiów
Zapisy (Rzeczywisty)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Etlik
-
Ankara, Etlik, Turcja (Türkiye), 06170
- Ankara Etlik City Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
The study population will consist of children aged 1-10 years who are scheduled for elective surgical procedures under general anesthesia at a tertiary care hospital. Participants will be selected from patients with American Society of Anesthesiologists (ASA) physical status I-II, representing generally healthy pediatric individuals. All eligible patients will be recruited from the operating room setting after obtaining written informed consent from their parents or legal guardians.
Opis
Inclusion Criteria:
- Children aged 1-10 years
- American Society of Anesthesiologists (ASA) physical status I-II
- Scheduled for elective (non-emergency) surgery under general anesthesia
- Planned use of a supraglottic airway device for airway management
- Written informed consent obtained from a parent or legal guardian
Exclusion Criteria:
- History of conditions associated with increased risk of aspiration (e.g., gastroesophageal reflux)
- Known or predicted difficult airway (e.g., Mallampati score ≥ 3)
- Congenital or acquired abnormalities of the face, neck, or upper airway
- Active upper respiratory tract infection
- Presence of significant pulmonary disease (e.g., asthma, bronchopulmonary dysplasia, cystic fibrosis)
- Body mass index above the 95th percentile for age (morbid obesity)
- Emergency surgery
- Previous complications related to supraglottic airway device use
- Failure of device placement or need to switch to an alternative airway management technique
- Refusal of participation by parent or legal guardian
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Modele obserwacyjne: COHORT
- Perspektywy czasowe: PROSPECTIVE
Kohorty i interwencje
Grupa / Kohorta |
Interwencja / Leczenie |
|---|---|
|
I-Gel Group
Participants in this group will receive the I-gel laryngeal mask airway during general anesthesia. After placement, oropharyngeal leak pressure will be measured, and ultrasonography will be used to assess device position and detect gastric insufflation. Additional parameters such as insertion time, ease of insertion, and perioperative complications will be recorded. |
I-gel Laryngeal Mask Airway: The I-gel is a second-generation supraglottic airway device with a non-inflatable cuff designed to provide an anatomical seal of the airway. In this study, the device will be selected according to patient weight and inserted following standard clinical practice during general anesthesia. Its performance will be evaluated using oropharyngeal leak pressure measurements and ultrasonographic assessment of gastric insufflation and device position.
Inne nazwy:
|
|
Air-Q SP Group
Participants in this group will receive the Air-Q SP laryngeal mask airway during general anesthesia. Similar measurements will be performed, including oropharyngeal leak pressure, ultrasonographic evaluation of device position and gastric insufflation, insertion time, ease of insertion, and perioperative complications. |
Air-Q SP Laryngeal Mask Airway: The Air-Q SP is a supraglottic airway device with a self-pressurizing, non-inflatable cuff designed to provide effective airway sealing. It will be selected based on patient weight and inserted using standard techniques. Its performance will be assessed using the same parameters as the I-gel, including oropharyngeal leak pressure, ultrasonographic evaluation of gastric insufflation, and device positioning.
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Oropharyngeal Leak Pressure (OLP)
Ramy czasowe: Immediately after device placement and at the end of the surgical procedure during anesthesia
|
Measured in cmH₂O after device placement and at the end of surgery using standard anesthesia machine settings (fresh gas flow 3 L/min, APL valve set to 30 cmH₂O). |
Immediately after device placement and at the end of the surgical procedure during anesthesia
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Gastric Insufflation
Ramy czasowe: Immediately after device placement and at the end of surgery
|
Assessed using ultrasonography by measuring gastric antral cross-sectional area (CSA) after device placement and at the end of surgery. |
Immediately after device placement and at the end of surgery
|
|
Device Position
Ramy czasowe: Immediately after device placement, after patient positioning, and at the end of surgery
|
Evaluated using ultrasonography to assess anatomical alignment at predefined time points. |
Immediately after device placement, after patient positioning, and at the end of surgery
|
|
Insertion Time
Ramy czasowe: At the time of device placement (periprocedural)
|
Measured in seconds from picking up the device to achieving effective ventilation. |
At the time of device placement (periprocedural)
|
|
Ease of Insertion
Ramy czasowe: At the time of device placement (periprocedural)
|
Assessed by the operator using a subjective scoring scale (1-4). |
At the time of device placement (periprocedural)
|
|
Perioperative Complications
Ramy czasowe: From device placement until discharge from the Post-Anesthesia Care Unit (PACU), up to 2 hours
|
Recorded as the occurrence of events such as desaturation, laryngospasm, coughing, vomiting, or blood staining on the device. |
From device placement until discharge from the Post-Anesthesia Care Unit (PACU), up to 2 hours
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Inne numery identyfikacyjne badania
- AEŞH-EK-2025-261
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .