Sammenligning af to luftvejsapparater (I-Gel og Air-Q) hos børn i alderen 1-10 år under generel anæstesi
Effekten af I-gel og Air-Q SP LMA'er på orofaryngeal lækagetryk og gastrisk insuflation hos børn: En ultralydsvejledt randomiseret undersøgelse
This study aims to compare two commonly used airway devices (I-gel and Air-Q) in children aged 1-10 years undergoing general anesthesia for surgery. These devices help doctors keep the airway open and support breathing during the operation. The study will evaluate how well each device works, how easy they are to place, and whether they cause air to enter the stomach. Ultrasound will be used to safely check the position of the device and detect any air in the stomach. The results of this study may help improve the safety and effectiveness of airway management in children during anesthesia.
Studieoversigt
Status
Betingelser
Intervention / Behandling
Detaljeret beskrivelse
This study is designed to compare two commonly used airway devices, I-gel and Air-Q, in children aged 1-10 years who are undergoing surgery under general anesthesia. These devices are used by anesthesiologists to keep the airway open and allow safe breathing during the procedure. Although both devices are widely used in clinical practice, their performance and safety in children may differ.
In this study, children will be randomly assigned to receive one of the two devices during anesthesia. The researchers will measure how effectively each device seals the airway, how easy and quick it is to place, and whether it causes air to enter the stomach, which can be an unwanted effect. Ultrasound imaging, a safe and non-invasive method, will be used to assess both the position of the device and the presence of air in the stomach.
All procedures performed in this study are part of standard clinical care, and no additional risks beyond routine anesthesia practice are expected. The information obtained from this study may help doctors choose the most effective and safest airway device for children, thereby improving the quality of anesthesia care and reducing potential complications.
Undersøgelsestype
Tilmelding (Faktiske)
Kontakter og lokationer
Studiesteder
-
-
Etlik
-
Ankara, Etlik, Tyrkiet (Türkiye), 06170
- Ankara Etlik City Hospital
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Prøveudtagningsmetode
Studiebefolkning
The study population will consist of children aged 1-10 years who are scheduled for elective surgical procedures under general anesthesia at a tertiary care hospital. Participants will be selected from patients with American Society of Anesthesiologists (ASA) physical status I-II, representing generally healthy pediatric individuals. All eligible patients will be recruited from the operating room setting after obtaining written informed consent from their parents or legal guardians.
Beskrivelse
Inclusion Criteria:
- Children aged 1-10 years
- American Society of Anesthesiologists (ASA) physical status I-II
- Scheduled for elective (non-emergency) surgery under general anesthesia
- Planned use of a supraglottic airway device for airway management
- Written informed consent obtained from a parent or legal guardian
Exclusion Criteria:
- History of conditions associated with increased risk of aspiration (e.g., gastroesophageal reflux)
- Known or predicted difficult airway (e.g., Mallampati score ≥ 3)
- Congenital or acquired abnormalities of the face, neck, or upper airway
- Active upper respiratory tract infection
- Presence of significant pulmonary disease (e.g., asthma, bronchopulmonary dysplasia, cystic fibrosis)
- Body mass index above the 95th percentile for age (morbid obesity)
- Emergency surgery
- Previous complications related to supraglottic airway device use
- Failure of device placement or need to switch to an alternative airway management technique
- Refusal of participation by parent or legal guardian
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Observationsmodeller: COHORT
- Tidsperspektiver: PROSPECTIVE
Kohorter og interventioner
Gruppe / kohorte |
Intervention / Behandling |
|---|---|
|
I-Gel Group
Participants in this group will receive the I-gel laryngeal mask airway during general anesthesia. After placement, oropharyngeal leak pressure will be measured, and ultrasonography will be used to assess device position and detect gastric insufflation. Additional parameters such as insertion time, ease of insertion, and perioperative complications will be recorded. |
I-gel Laryngeal Mask Airway: The I-gel is a second-generation supraglottic airway device with a non-inflatable cuff designed to provide an anatomical seal of the airway. In this study, the device will be selected according to patient weight and inserted following standard clinical practice during general anesthesia. Its performance will be evaluated using oropharyngeal leak pressure measurements and ultrasonographic assessment of gastric insufflation and device position.
Andre navne:
|
|
Air-Q SP Group
Participants in this group will receive the Air-Q SP laryngeal mask airway during general anesthesia. Similar measurements will be performed, including oropharyngeal leak pressure, ultrasonographic evaluation of device position and gastric insufflation, insertion time, ease of insertion, and perioperative complications. |
Air-Q SP Laryngeal Mask Airway: The Air-Q SP is a supraglottic airway device with a self-pressurizing, non-inflatable cuff designed to provide effective airway sealing. It will be selected based on patient weight and inserted using standard techniques. Its performance will be assessed using the same parameters as the I-gel, including oropharyngeal leak pressure, ultrasonographic evaluation of gastric insufflation, and device positioning.
Andre navne:
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Oropharyngeal Leak Pressure (OLP)
Tidsramme: Immediately after device placement and at the end of the surgical procedure during anesthesia
|
Measured in cmH₂O after device placement and at the end of surgery using standard anesthesia machine settings (fresh gas flow 3 L/min, APL valve set to 30 cmH₂O). |
Immediately after device placement and at the end of the surgical procedure during anesthesia
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Gastric Insufflation
Tidsramme: Immediately after device placement and at the end of surgery
|
Assessed using ultrasonography by measuring gastric antral cross-sectional area (CSA) after device placement and at the end of surgery. |
Immediately after device placement and at the end of surgery
|
|
Device Position
Tidsramme: Immediately after device placement, after patient positioning, and at the end of surgery
|
Evaluated using ultrasonography to assess anatomical alignment at predefined time points. |
Immediately after device placement, after patient positioning, and at the end of surgery
|
|
Insertion Time
Tidsramme: At the time of device placement (periprocedural)
|
Measured in seconds from picking up the device to achieving effective ventilation. |
At the time of device placement (periprocedural)
|
|
Ease of Insertion
Tidsramme: At the time of device placement (periprocedural)
|
Assessed by the operator using a subjective scoring scale (1-4). |
At the time of device placement (periprocedural)
|
|
Perioperative Complications
Tidsramme: From device placement until discharge from the Post-Anesthesia Care Unit (PACU), up to 2 hours
|
Recorded as the occurrence of events such as desaturation, laryngospasm, coughing, vomiting, or blood staining on the device. |
From device placement until discharge from the Post-Anesthesia Care Unit (PACU), up to 2 hours
|
Samarbejdspartnere og efterforskere
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Faktiske)
Studieafslutning (Faktiske)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Andre undersøgelses-id-numre
- AEŞH-EK-2025-261
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .