Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Untersuchung der automatischen Anpassung der dynamischen AFO

30. Oktober 2026 aktualisiert von: Joan E Sanders, University of Washington

Offloading Ankle Foot Orthoses (AFOs) are devices designed for people following lower-limb reconstruction to restore mobility by reducing mechanical loading through the injury site and redistributing it proximally. While they perform well for some users, their current form limits full functional potential and may put joints proximal to the injury at risk of long-term damage. This study is directed toward designing and testing a lightweight, variable stiffness, dynamic brace that can adjust in response to user activity.

Studienübersicht

Studientyp

Interventionell

Einschreibung (Geschätzt)

22

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

  • Name: Katheryn Allyn, CPO, LPO
  • Telefonnummer: 206-390-0228

Studieren Sie die Kontaktsicherung

  • Name: Joan Sanders, PhD
  • Telefonnummer: 206-221-5872
  • E-Mail: jsanders@uw.edu

Studienorte

    • Washington
      • Seattle, Washington, Vereinigte Staaten, 98105
        • Rekrutierung
        • University of Washington, Dept. of Bioengineering
        • Kontakt:

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Ja

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria (Healthy Volunteers):

-able to run continuously for 1 minute

Inclusion Criteria (All Other Volunteers)

  • prescribed an offloading Ankle-Foot Orthosis (AFO) for walking/running
  • Use prescribed offloading AFO at least 20 hours per week
  • Prescribed AFO strut length of at least 200 mm
  • Able to run continuously for 1 minute

Exclusion Criteria (Healthy Volunteers):

  • limited sensation in the lower limbs
  • use an assistive device

Exclusion Criteria (All Other Volunteers):

  • Unable to ambulate (walk/run) continuously with AFO for at least 1 minute
  • Unable to sit, stand, or negotiate a step onto lab treadmill

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Unterstützende Pflege
  • Zuteilung: Zufällig
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Aim 2

Participants will carry out a protocol comprised of treadmill walking in a laboratory setting while wearing the Dynamic AFO device.

The Dynamic AFO is able to adjust in stiffness depending on activity.

Experimental: Aim 3

Participants will be asked to take the Dynamic AFO home and wear the device for up to 4 weeks. The device will be set in either an adjustment-capable mode, or a "locked" mode that functions similar to their own orthotic--the order in which they are tested will be randomized.

The Dynamic AFO is able to adjust in stiffness depending on activity.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Time Running Per Day
Zeitfenster: Calculated across all days of data collection (up to 4 weeks).

Collected while participant uses device in free-living environment.

Calculated across all days of data collection (up to 4 weeks).
Longest Running Bout Duration
Zeitfenster: Across all days of data collection (up to 4 weeks), the longest bout of continuous activity will be identified (minutes).

Collected while participant uses device in free-living environment.

Across all days of data collection (up to 4 weeks), the longest bout of continuous activity will be identified (minutes).
PROMIS-Fatigue
Zeitfenster: Following their time out in their free-living environment (up to 4 weeks at a time), participants will be asked to complete a questionnaire related to fatigue.

Participants will be asked to fill out a questionnaire related to their experience using the variable stiffness AFO out of lab in various test configurations. Each PROMIS-Fatigue question asks participants to rank on a scale from 1 to 5 (categorical options), with higher scores indicating a greater level of fatigue.

Following their time out in their free-living environment (up to 4 weeks at a time), participants will be asked to complete a questionnaire related to fatigue.
Pain Score
Zeitfenster: Following their time out in their free-living environment (up to 4 weeks at a time), participants will be asked to complete a questionnaire related to pain.

Participants will be asked to fill out a questionnaire related to their experience using the variable stiffness AFO out of lab in various test configurations. Each Pain-Score question asks participants to rank on a scale from 1 to 10 (categorical options), with higher scores indicating a greater level of pain.

Following their time out in their free-living environment (up to 4 weeks at a time), participants will be asked to complete a questionnaire related to pain.
Orthotic Evaluation Questionnaire (OEQ)
Zeitfenster: Following their time out in their free-living environment (up to 4 weeks at a time), participants will be asked to complete an OEQ.

Similar to the Prosthesis Evaluation Questionnaire (PEQ), the OEQ will ask various questions concerning their experience wearing the variable stiffness AFO. Participants will rate their overall satisfaction, ability to ambulate, the health of their limb, the utility of the device, and their overall well-being after wearing the device.

Following their time out in their free-living environment (up to 4 weeks at a time), participants will be asked to complete an OEQ.
Running Speed on Treadmill
Zeitfenster: In-lab testing will occur over the course of up to 2 hours at a time.

Participants carrying out the in-lab protocol will be asked to run using the variable stiffness AFO and running speed will be documented at various time points.

In-lab testing will occur over the course of up to 2 hours at a time.
Extended Figure-of-8 Test
Zeitfenster: In-lab testing wil occur over the course of up to 2 hours at a time.

Participants carrying out the in-lab protocol will be asked to do a Figure-of-8 test.

In-lab testing wil occur over the course of up to 2 hours at a time.

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: Joan E Sanders, PhD, University of Washington

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

30. November 2020

Primärer Abschluss (Geschätzt)

30. November 2027

Studienabschluss (Geschätzt)

1. Dezember 2027

Studienanmeldedaten

Zuerst eingereicht

2. November 2020

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

9. November 2020

Zuerst gepostet (Tatsächlich)

10. November 2020

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

4. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

30. Oktober 2026

Zuletzt verifiziert

1. April 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Schlüsselwörter

Andere Studien-ID-Nummern

  • STUDY00009120

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Ja

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren