- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT05254587
Precisione della cheratometria totale IOLMASTER 700 (TK)
Precisione della cheratometria totale (TK) IOLMASTER 700 in pazienti sottoposti a intervento di cataratta con correzione della vista post-laser
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
California
-
Bakersfield, California, Stati Uniti, 93309
- Empire Eye & Laser Center
-
Los Angeles, California, Stati Uniti, 90067
- Advanced Vision Care
-
Torrance, California, Stati Uniti, 90505
- Wolstan & Goldberg Eye Associates
-
-
Maryland
-
Bowie, Maryland, Stati Uniti, 20716
- Solomon Eye Physicians and Surgeons
-
-
Pennsylvania
-
Bala-Cynwyd, Pennsylvania, Stati Uniti, 19004
- Ophthalmic Partners PC
-
-
South Carolina
-
Charleston, South Carolina, Stati Uniti, 29425
- MUSC Storm Eye Institute29425
-
-
Virginia
-
Norfolk, Virginia, Stati Uniti, 23502
- Virginia eye consultant
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Metodo di campionamento
Popolazione di studio
Descrizione
Criterio di inclusione:
- Adulti di età pari o superiore a 18 anni al momento dell'intervento di cataratta.
Il paziente ha subito un intervento di cataratta LVC e IOL entro 3 anni o è programmato per sottoporsi a intervento di cataratta IOL eseguito per il trattamento della cataratta visivamente significativa.
Nota: le uniche IOL consentite per l'uso in questo studio sono lenti monofocali (ZCBOO, LI61AO, SN60WF, SA60WF, MX60E) e toriche (Tecnis 2 ZCU, ZCT, SN6ATx, SA6ATx, MX60ET).
- Miglior potenziale di acuità visiva a distanza corretta (BCDVA) di 20/30 o superiore (misurato dal misuratore di acuità retinica (RAM) o dal misuratore di acuità potenziale (PAM).
- Pazienti che hanno una refrazione manifesta miope o ipermetrope dopo una precedente LVC.
- Pazienti che hanno misurazioni biometriche (inclusa la lunghezza assiale) per l'intervento di cataratta IOL eseguito prima dell'intervento con IOLMaster700, incluso Barrett True K /TK.
- Firmato e ricevuto una copia del consenso informato scritto firmato (riguarda solo i potenziali soggetti).
- Per i potenziali pazienti, disponibilità e capacità di rispettare il programma per le visite di follow-up e le valutazioni postoperatorie.
Criteri di esclusione:
Pazienti con una storia di uno dei seguenti:
- Patologia corneale - Distrofia della membrana basale epiteliale (EMBD), astigmatismo irregolare, LASIK/PRK decentrata, cheratotomia radiale (RK), distrofia di Fuchs
- Patologia retinica - Membrana epiretinica visivamente significativa (ERM) con perdita del contorno foveale, drusen grande/medio, edema maculare cistoide (CME), anamnesi di distacco retinico
- Neuropatia ottica
- Glaucoma avanzato
- Ambliopia
- Strabismo
- Difetto pupillare afferente relativo (RAPD) che indica una neuropatia ottica.
- Pazienti con una precedente storia di intervento chirurgico di estrazione del lenticolo con piccola incisione (SMILE) e/o procedura di filtraggio del glaucoma (definita come tubi o trabeculectomia) diversa dalla cheratectomia fotorefrattiva (PRK) o LASIK.
- Paziente che ha dovuto sottoporsi a misurazione A-scan per recuperare i valori di lunghezza assiale (AL).
- Il paziente ha subito un intervento di cataratta LVC e IOL entro 3 anni o è programmato per sottoporsi a intervento di cataratta IOL eseguito per il trattamento di cataratta visivamente significativa con la presenza o l'intenzione di impiantare una lente multifocale, a profondità di fuoco estesa, accomodante e regolabile in base alla luce (come , ma non limitato a, TFAT / TFNT; DAT / DFT; ICB00/DIB/DIU/DAT; ZXT; DFW; SN6AD1; AT-50; RxSIGHT).
- Pazienti in cui l'occhio dello studio presenta complicazioni chirurgiche intraoperatorie o complessi interventi di cataratta (vitrectomia, sutura corneale).
- Pazienti con precedente LVC in cui un occhio è stato trattato per la miopia e l'altro occhio è stato trattato per l'ipermetropia.
- Il paziente sta partecipando a un altro studio.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
Retrospettiva
|
Verranno eseguiti 4 diversi metodi di calcolo della lente intraoculare (IOL) (Haigis TK, calcolatore ASCRS, Barrett True K Classic K, Barrett True K TK) utilizzando la biometria preoperatoria e i dati di rifrazione postoperatoria.
|
|
Prospettiva
|
Verranno eseguiti 4 diversi metodi di calcolo della lente intraoculare (IOL) (Haigis TK, calcolatore ASCRS, Barrett True K Classic K, Barrett True K TK) utilizzando la biometria preoperatoria e i dati di rifrazione postoperatoria.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Valutazione totale dell'accuratezza della cheratometria
Lasso di tempo: 4 settimane
|
Soggetti che utilizzano la cheratometria totale entro (+/- 0,50 D, +/- 0,75 D, +/- 1,00 D) rispetto alla percentuale di soggetti che utilizzano letture cheratometriche tradizionali.
|
4 settimane
|
Collaboratori e investigatori
Sponsor
Collaboratori
Investigatori
- Investigatore principale: Nicole Fram, MD, Advanced Vision Care
Pubblicazioni e link utili
Pubblicazioni generali
- Abulafia A, Hill WE, Koch DD, Wang L, Barrett GD. Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia. J Cataract Refract Surg. 2016 Mar;42(3):363-9. doi: 10.1016/j.jcrs.2015.11.039. Epub 2016 Mar 19.
- Wang L, Tang M, Huang D, Weikert MP, Koch DD. Comparison of Newer Intraocular Lens Power Calculation Methods for Eyes after Corneal Refractive Surgery. Ophthalmology. 2015 Dec;122(12):2443-9. doi: 10.1016/j.ophtha.2015.08.037. Epub 2015 Oct 14.
- Moshirfar M, Wagner WD, Linn SH, Skanchy DF, Brown TW, Gomez AT, Goldberg JL, Ronquillo YC, Hoopes PC Jr. Astigmatic correction with implantation of a light adjustable vs monofocal lens: a single site analysis of a randomized controlled trial. Int J Ophthalmol. 2019 Jul 18;12(7):1101-1107. doi: 10.18240/ijo.2019.07.08. eCollection 2019.
- Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL. Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg. 2011 Jan;37(1):63-71. doi: 10.1016/j.jcrs.2010.07.032.
- Kane JX, Van Heerden A, Atik A, Petsoglou C. Accuracy of 3 new methods for intraocular lens power selection. J Cataract Refract Surg. 2017 Mar;43(3):333-339. doi: 10.1016/j.jcrs.2016.12.021.
- Anter AM, Bleeker AR, Shammas HJ, Suraneni S, Kingrey B, Murphy DA, Leal S, Ghalibafan S, Tonk RS, Cooke DL, Riaz KM. Comparison of Legacy and New No-History IOL Power Calculation Formulas in Postmyopic Laser Vision Correction Eyes. Am J Ophthalmol. 2024 Aug;264:44-52. doi: 10.1016/j.ajo.2024.03.014. Epub 2024 Mar 20.
- Suraneni S, Bleeker AR, Anter AM, Leal S, Murphy DA, Riaz KM, Cooke DL, Tonk RS. Intraocular Lens Power Calculations in Posthyperopic Laser Vision Correction Eyes: Comparing Legacy and New No-History Formulas. Am J Ophthalmol. 2026 Jan;281:118-125. doi: 10.1016/j.ajo.2025.09.010. Epub 2025 Sep 9.
- Kenny PI, Kozhaya K, Truong P, Wang L, Koch DD, Weikert MP. Performance of IOL calculation formulas that use measured posterior corneal power in eyes following myopic laser vision correction. J Cataract Refract Surg. 2024 Jan 1;50(1):7-11. doi: 10.1097/j.jcrs.0000000000001300.
- Yeo TK, Heng WJ, Pek D, Wong J, Fam HB. Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery. Eye (Lond). 2021 Jun;35(6):1705-1711. doi: 10.1038/s41433-020-01159-5. Epub 2020 Aug 31.
- Lawless M, Jiang JY, Hodge C, Sutton G, Roberts TV, Barrett G. Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery. Clin Exp Ophthalmol. 2020 Aug;48(6):749-756. doi: 10.1111/ceo.13760. Epub 2020 Apr 27.
- Masket S, Masket SE. Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation. J Cataract Refract Surg. 2006 Mar;32(3):430-4. doi: 10.1016/j.jcrs.2005.12.106.
- Gale RP, Saldana M, Johnston RL, Zuberbuhler B, McKibbin M. Benchmark standards for refractive outcomes after NHS cataract surgery. Eye (Lond). 2009 Jan;23(1):149-52. doi: 10.1038/sj.eye.6702954. Epub 2007 Aug 24.
- Fram NR, Masket S, Wang L. Comparison of Intraoperative Aberrometry, OCT-Based IOL Formula, Haigis-L, and Masket Formulae for IOL Power Calculation after Laser Vision Correction. Ophthalmology. 2015 Jun;122(6):1096-101. doi: 10.1016/j.ophtha.2015.01.027. Epub 2015 Mar 10.
- Ladas JG, Stark WJ. Calculating IOL power after refractive surgery. J Cataract Refract Surg. 2004 Dec;30(12):2458; author reply 2458-9. doi: 10.1016/j.jcrs.2004.10.013. No abstract available.
- Gimbel HV, Sun R. Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis. J Cataract Refract Surg. 2001 Apr;27(4):571-6. doi: 10.1016/s0886-3350(00)00795-1.
- Joffe SN. The 25th Anniversary of Laser Vision Correction in the United States. Clin Ophthalmol. 2021 Mar 17;15:1163-1172. doi: 10.2147/OPTH.S299752. eCollection 2021.
- Rossi T, Romano MR, Iannetta D, Romano V, Gualdi L, D'Agostino I, Ripandelli G. Cataract surgery practice patterns worldwide: a survey. BMJ Open Ophthalmol. 2021 Jan 13;6(1):e000464. doi: 10.1136/bmjophth-2020-000464. eCollection 2021.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- AVC-005
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Cataratta
-
RxSight, Inc.Iscrizione su invito
-
Adaptilens, Inc.Non ancora reclutamentoAphakia Cataract
Prove cliniche su IOLMASTER 700 TK
-
OFTALVIST (Oftalmología Vistahermosa S.L)Completato
-
Berkeley Eye CenterAlcon ResearchCompletato
-
Cylite Pty LtdCompletatoOcchi normali | Occhi anormaliStati Uniti
-
Prim. Prof. Dr. Oliver Findl, MBACompletato
-
Democritus University of ThraceCompletato
-
Mahidol UniversityCompletato
-
Teikoku Seiyaku Co., Ltd.ClinSearch; CRM Biometrics GmbH; SocraTec R&D GmbH; SocraMetrics GmbH; Clinigen Clinical...Completato
-
AGC Biologics S.p.A.CompletatoNeoplasie ematologicheItalia, Israele, Regno Unito, Germania, Grecia
-
Carl Zeiss Meditec AGNon ancora reclutamentoCataratta | Astigmatismo corneale | Difetto corneale | Deformità corneale | Opacità della lente | Impianto di lenti artificiali