SAPIEN 3 Ultra RESILIA 瓣膜的瓣膜性能:中央超声心动图分析的前瞻性登记。

标题 SAPIEN 3 Ultra RESILIA 瓣膜的瓣膜性能:中央超声心动图分析的前瞻性登记。

The issue of valve durability has become one of the most important aspects in the TAVR field in recent years since transcatheter aortic valve replacement has been progressively applied to younger patients with a low co-morbidity burden. The SAPIEN 3 Ultra RESILIA valve represents the last generation of the SAPIEN valve system and includes several important iterations (newer leaflet calcium-blocking technology targeting calcium-attracting free aldehydes, dry tissue storage, newer skirt textile design) that should translate into a favorable impact on valve durability at mid- to long- term follow-up

研究概览

详细说明

Prospective observational registry including patients with severe aortic stenosis undergoing TAVR with the SAPIEN 3 Ultra RESILIA valve. All patients who will survive the procedure will undergo a clinical and echocardiographic follow-up at 1-3 months (± 15 days), at 1-year (±30 days), 3-5 year (±30 days), 6-8 year (±30 days) and 9-10 year (±30 days) after valve implantation. Transthoracic echocardiography (TTE) exams (baseline, 1-3-month, 1 year, 3-5 years, 6-8 years, and 9-10 years post-procedure) will be evaluated in a Centralized Echocardiographic Core Lab at the Quebec Heart and Lung Institute. The measurements obtained in the Core Lab regarding transvalvular gradient, EOA, PPM and PVL at 1-3 months will determine the primary outcome of the study.

研究类型

观察性的

注册 (估计的)

150

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

学习地点

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 80年 (成人、年长者)

接受健康志愿者

不适用

有资格学习的性别

全部

取样方法

非概率样本

研究人群

Population Patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 Ultra RESILIA valve.

描述

Inclusion Criteria:

  • Inclusion criteria - Patients with severe aortic stenosis undergoing transarterial TAVR with the SAPIEN 3 Ultra RESILIA valve.
  • Successful valve implantation of the SAPIEN 3 Ultra RESILIA valve.

VARC-3- defined technical success defined as:

  • Freedom from mortality
  • Successful access, delivery of the device, and retrieval of the delivery system
  • Correct positioning of a single prosthetic heart valve into the proper anatomical location
  • Freedom from surgery or intervention related to the device (excluding permanent pacemaker) or to a major vascular or access related, or cardiac structural complication - Absence of severe procedural or in-hospital complications (VARC-3 definitions): mortality, stroke, bleeding type 2-4, myocardial infarction, need for a second valve, valve embolization, coronary obstruction, annular rupture.

Exclusion Criteria:

  • Age >80 years
  • Severe pulmonary disease (FEV1 <50% predicted or need for home oxygen)
  • Severe renal dysfunction (eGFR <30 ml/min/1.73m2)
  • Frailty (Clinical Frailty Scale > 4)
  • Severe coronary disease (SYNTAX score >32)
  • Left ventricular ejection fraction ≤30%
  • Moderate-to-severe mitral regurgitation
  • Severe tricuspid regurgitation
  • Pulmonary systolic pressure >60 mmHg
  • STS-PROM >5%
  • Any disease leading to a life expectancy <5 years

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 观测模型:COHORT
  • 时间观点:PROSPECTIVE

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Transvalvular gradient
大体时间:1-3 months

Residual (peak and mean) transvalvular gradient

1-3 months
Effective orifice area (EOA)
大体时间:1-3 months

EOA evaluated by echocardiography imaging

1-3 months
Prosthesis-patient mismatch
大体时间:1-3 months

Moderate or severe prothesis-patient mismatch (defines as an index aortic valve area 0.85-0.66 cm2/m2 (moderate), ≤0.65 cm2/m2 (severe) for patient with BMI ˂30km/m2 and 0.70-0.56 cm2/m2 (moderate), ≤0.55 cm2/m2 (severe) for patient with BMI ≥30km/m2 and/or moderate-severe aortic regurgitation (AR) (VARC-3 definition).

1-3 months
Paravalvular leaks
大体时间:1-3 months

Paravalvular leaks evaluated by echocardiography imaging

1-3 months

次要结果测量

结果测量
措施说明
大体时间
Transvalvular gradient
大体时间:1-, 3-5-, 6-8-, and 9-10-year follow-up.

Residual (maximal and mean) transvalvular gradient

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Effective orifice area (EOA)
大体时间:1-, 3-5-, 6-8-, and 9-10-year follow-up.

EOA evaluated by echocardiography imaging

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Bioprosthetic valve dysfunction
大体时间:1-, 3-5-, 6-8-, and 9-10-year follow-up.

Bioprosthetic valve dysfunction evaluated by VARC3 criteria

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Paravalvular leaks
大体时间:1-, 3-5-, 6-8-, and 9-10-year follow-up.

Paravalvular leaks evaluated by echocardiography imaging

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Bioprosthetic valve dysfunction
大体时间:yearly

Incidence rate (per 100 patient-years) of bioprosthetic valve dysfunction (stage 2 or 3)

yearly
Bioprosthetic valve failure
大体时间:yearly

Incidence rate (per 100 patient-years) of bioprosthetic valve failure

yearly
Bioprosthetic valve failure
大体时间:1-, 3-5-, 6-8-, and 9-10-year follow-up.

Bioprosthetic valve failure evaluated by VARC3 criteria

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Clinical events
大体时间:1month and yearly up to 10-year

Individual: mortality, stroke, bleeding type 2-4, cardiac rehospitalization, heart failure rehospitalization

1month and yearly up to 10-year
Valve thrombosis
大体时间:1-3 months and yearly up to 10-year

Number of patients with valve thrombosis

1-3 months and yearly up to 10-year
Valve endocarditis
大体时间:1-3 months and yearly up to 10-year

Number of patients with valve endocarditis

1-3 months and yearly up to 10-year

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Josep Rodés-Cabau, MD、IUCPQ-UL
  • 研究主任:Emilie Pelletier beaumont, MSc、Fondation IUCPQ

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

一般刊物

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2024年5月16日

初级完成 (估计的)

2027年10月1日

研究完成 (估计的)

2034年9月1日

研究注册日期

首次提交

2024年5月15日

首先提交符合 QC 标准的

2024年5月15日

首次发布 (实际的)

2024年5月20日

研究记录更新

最后更新发布 (实际的)

2026年11月4日

上次提交的符合 QC 标准的更新

2026年11月2日

最后验证

2026年11月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅