Performances valvulaires de la valve SAPIEN 3 Ultra RESILIA : un registre prospectif avec analyse d'échocardiographie centrale.

Titre Performances valvulaires de la valve SAPIEN 3 Ultra RESILIA : un registre prospectif avec analyse d'échocardiographie centrale.

The issue of valve durability has become one of the most important aspects in the TAVR field in recent years since transcatheter aortic valve replacement has been progressively applied to younger patients with a low co-morbidity burden. The SAPIEN 3 Ultra RESILIA valve represents the last generation of the SAPIEN valve system and includes several important iterations (newer leaflet calcium-blocking technology targeting calcium-attracting free aldehydes, dry tissue storage, newer skirt textile design) that should translate into a favorable impact on valve durability at mid- to long- term follow-up

Aperçu de l'étude

Description détaillée

Prospective observational registry including patients with severe aortic stenosis undergoing TAVR with the SAPIEN 3 Ultra RESILIA valve. All patients who will survive the procedure will undergo a clinical and echocardiographic follow-up at 1-3 months (± 15 days), at 1-year (±30 days), 3-5 year (±30 days), 6-8 year (±30 days) and 9-10 year (±30 days) after valve implantation. Transthoracic echocardiography (TTE) exams (baseline, 1-3-month, 1 year, 3-5 years, 6-8 years, and 9-10 years post-procedure) will be evaluated in a Centralized Echocardiographic Core Lab at the Quebec Heart and Lung Institute. The measurements obtained in the Core Lab regarding transvalvular gradient, EOA, PPM and PVL at 1-3 months will determine the primary outcome of the study.

Type d'étude

Observationnel

Inscription (Estimé)

150

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Sauvegarde des contacts de l'étude

Lieux d'étude

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 80 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

N/A

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Population Patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 Ultra RESILIA valve.

La description

Inclusion Criteria:

  • Inclusion criteria - Patients with severe aortic stenosis undergoing transarterial TAVR with the SAPIEN 3 Ultra RESILIA valve.
  • Successful valve implantation of the SAPIEN 3 Ultra RESILIA valve.

VARC-3- defined technical success defined as:

  • Freedom from mortality
  • Successful access, delivery of the device, and retrieval of the delivery system
  • Correct positioning of a single prosthetic heart valve into the proper anatomical location
  • Freedom from surgery or intervention related to the device (excluding permanent pacemaker) or to a major vascular or access related, or cardiac structural complication - Absence of severe procedural or in-hospital complications (VARC-3 definitions): mortality, stroke, bleeding type 2-4, myocardial infarction, need for a second valve, valve embolization, coronary obstruction, annular rupture.

Exclusion Criteria:

  • Age >80 years
  • Severe pulmonary disease (FEV1 <50% predicted or need for home oxygen)
  • Severe renal dysfunction (eGFR <30 ml/min/1.73m2)
  • Frailty (Clinical Frailty Scale > 4)
  • Severe coronary disease (SYNTAX score >32)
  • Left ventricular ejection fraction ≤30%
  • Moderate-to-severe mitral regurgitation
  • Severe tricuspid regurgitation
  • Pulmonary systolic pressure >60 mmHg
  • STS-PROM >5%
  • Any disease leading to a life expectancy <5 years

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Modèles d'observation: COHORT
  • Perspectives temporelles: PROSPECTIVE

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Transvalvular gradient
Délai: 1-3 months

Residual (peak and mean) transvalvular gradient

1-3 months
Effective orifice area (EOA)
Délai: 1-3 months

EOA evaluated by echocardiography imaging

1-3 months
Prosthesis-patient mismatch
Délai: 1-3 months

Moderate or severe prothesis-patient mismatch (defines as an index aortic valve area 0.85-0.66 cm2/m2 (moderate), ≤0.65 cm2/m2 (severe) for patient with BMI ˂30km/m2 and 0.70-0.56 cm2/m2 (moderate), ≤0.55 cm2/m2 (severe) for patient with BMI ≥30km/m2 and/or moderate-severe aortic regurgitation (AR) (VARC-3 definition).

1-3 months
Paravalvular leaks
Délai: 1-3 months

Paravalvular leaks evaluated by echocardiography imaging

1-3 months

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Transvalvular gradient
Délai: 1-, 3-5-, 6-8-, and 9-10-year follow-up.

Residual (maximal and mean) transvalvular gradient

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Effective orifice area (EOA)
Délai: 1-, 3-5-, 6-8-, and 9-10-year follow-up.

EOA evaluated by echocardiography imaging

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Bioprosthetic valve dysfunction
Délai: 1-, 3-5-, 6-8-, and 9-10-year follow-up.

Bioprosthetic valve dysfunction evaluated by VARC3 criteria

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Paravalvular leaks
Délai: 1-, 3-5-, 6-8-, and 9-10-year follow-up.

Paravalvular leaks evaluated by echocardiography imaging

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Bioprosthetic valve dysfunction
Délai: yearly

Incidence rate (per 100 patient-years) of bioprosthetic valve dysfunction (stage 2 or 3)

yearly
Bioprosthetic valve failure
Délai: yearly

Incidence rate (per 100 patient-years) of bioprosthetic valve failure

yearly
Bioprosthetic valve failure
Délai: 1-, 3-5-, 6-8-, and 9-10-year follow-up.

Bioprosthetic valve failure evaluated by VARC3 criteria

1-, 3-5-, 6-8-, and 9-10-year follow-up.
Clinical events
Délai: 1month and yearly up to 10-year

Individual: mortality, stroke, bleeding type 2-4, cardiac rehospitalization, heart failure rehospitalization

1month and yearly up to 10-year
Valve thrombosis
Délai: 1-3 months and yearly up to 10-year

Number of patients with valve thrombosis

1-3 months and yearly up to 10-year
Valve endocarditis
Délai: 1-3 months and yearly up to 10-year

Number of patients with valve endocarditis

1-3 months and yearly up to 10-year

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Josep Rodés-Cabau, MD, IUCPQ-UL
  • Directeur d'études: Emilie Pelletier beaumont, MSc, Fondation IUCPQ

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

16 mai 2024

Achèvement primaire (Estimé)

1 octobre 2027

Achèvement de l'étude (Estimé)

1 septembre 2034

Dates d'inscription aux études

Première soumission

15 mai 2024

Première soumission répondant aux critères de contrôle qualité

15 mai 2024

Première publication (Réel)

20 mai 2024

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

4 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

2 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner