Titration of Continuous Positive Airway Pressure Could Predict Success of Oral Appliance to Treat Sleep Apnea

25 ottobre 2011 aggiornato da: Prof. Dr. Lia Azeredo-Bittencourt, Associacao Fundo de Incentivo a Psicofarmcologia

Optimal Titration of Continuous Positive Airway Pressure Could Predict Success of Oral Appliance to Treat Obstructive Sleep Apnea Syndrome

Background: The oral appliances have been increasingly used in the treatment of primary snoring and in patients with mild obstructive sleep apnea syndrome besides being treatment options in adults with moderate to severe sleep apnea who did not accept or adapt to continuous positive airway pressure (CPAP). It is not well established yet in the literature, which patients with mild to moderate OSA will present a good response to treatment with oral appliances.

Objective: To determine a value of CPAP pressure that correlates with a favorable response to the use of oral appliance in patients with mild to moderate sleep apnea.

Patients and Methods: Two groups of 30 male patients (25-65 years, body mass index < 35 kg/m2) will be selected: the first group with an apnea-hypopnea index (AHI) between 5 and 15 events per hour of sleep and the second one with an AHI between 15 and 30 events per hour of sleep. Each patient will undergo three polysomnographic recordings (baseline, CPAP titration, after two months of treatment with oral appliance). Subjective (sleep disorders questionnaire, the Epworth Sleepiness Scale, and sleep diaries) and objective (polysomnography) parameters of sleep will be evaluated, besides the quality of life (SF-36), mood (POMS), and anthropometric measurements (neck circumference and craniofacial characteristic). Good response to treatment with the AIO will be considered as a 50% reduction in the baseline AHI index or AHI after treatment less than 5 events per hour of sleep.

Panoramica dello studio

Stato

Sconosciuto

Intervento / Trattamento

Tipo di studio

Interventistico

Iscrizione (Anticipato)

60

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • SP
      • São Paulo, SP, Brasile, 04023-062
        • Reclutamento
        • Instituto do Sono/ Associação Fundo de Incentivo a Psicofarmacologia
        • Investigatore principale:
          • Lia Rita A Bittencourt, MD, PhD
        • Contatto:
        • Contatto:
        • Sub-investigatore:
          • Thays CA Cunha

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 25 anni a 65 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Maschio

Descrizione

Inclusion Criteria:

  • Male subjects aged between 25 and 65 years old
  • Epworth sleepiness Scale > 9
  • Apnea-hypopnea index between 5 and 30

Exclusion Criteria:

  • Presence of clinical disease (chronic obstructive pulmonary disease, asthma) and other sleep disorders.
  • Presence of anatomical obstructive upper airway, tonsil grade III e IV, septal deviation and grade III that may affect the outcome of CPAP
  • Loss of posterior dental support to undermine the retention of oral appliance
  • Active of periodontal disease, compared Dental crow/dental root less than or equal to 1 (c/r ≤ 1) need primary dental care (cavities, root canal treatment or retreatment, dentures, i.e. outlying), open bite
  • Protrusive displacement lass then five millimeters
  • Limited mouth opening
  • Alcoholism
  • Use of sleep-inducing medications
  • Habits or occupation that lead to sleep deprivation or alteration of the sleep-wake cycle
  • Intolerance to CPAP
  • Obesity grade II (moderate) or III (severe)

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Separare

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Objective sleep parameters
Lasso di tempo: two months after the baseline recording
polysomnographic date of sleep stages percentages, sleep efficience, arousals, apnea-hypopnea index, oxyhemoglobin saturation
two months after the baseline recording

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Subjective sleep parameters
Lasso di tempo: two months after the baseline recording
Sleep disorders questionnaire, the Epworth Sleepiness Scale, and sleep diaries
two months after the baseline recording
Quality of life, mood, and anthropometric measurements
Lasso di tempo: two months after the baseline recording
SF-36, POMS, neck circumference and craniofacial characteristic
two months after the baseline recording

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Lia Rita A Bittencourt, MD, PhD, Federal University of São Paulo

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio

1 ottobre 2010

Completamento primario (Anticipato)

1 novembre 2011

Date di iscrizione allo studio

Primo inviato

14 aprile 2011

Primo inviato che soddisfa i criteri di controllo qualità

14 aprile 2011

Primo Inserito (Stima)

18 aprile 2011

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Stima)

26 ottobre 2011

Ultimo aggiornamento inviato che soddisfa i criteri QC

25 ottobre 2011

Ultimo verificato

1 ottobre 2011

Maggiori informazioni

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .