Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Studio di fattibilità iniziale di Impella ECP (ECP EFS)

17 settembre 2026 aggiornato da: Abiomed Inc.

Uso di Impella ECP in pazienti sottoposti a intervento coronarico percutaneo elettivo ad alto rischio: uno studio di fattibilità iniziale

The Impella ECP EFS is a prospective, multicenter, single-arm, feasibility study evaluating the safety of the Impella ECP device in adult patients undergoing an elective or urgent high-risk percutaneous coronary intervention.

Panoramica dello studio

Stato

Attivo, non reclutante

Intervento / Trattamento

Descrizione dettagliata

This is a prospective, multicenter, single-arm, feasibility study evaluating the safety of the Impella ECP device in adult patients undergoing an elective or urgent high-risk percutaneous coronary intervention (HRPCI). Additionally, this study will evaluate the feasibility of placing the ECP pump across the aortic valve without the use of a guidewire and assess the ability of the pump to provide sufficient hemodynamic support during a HRPCI. Investigational device products include: Impella ECP pump system (a percutaneous transvalvular micro-axial blood pump), 9Fr introducer sheath, and the automated Impella controller with revised console software to allow control of the Impella ECP.

Following informed consent, subjects eligible for a HRPCI that meet all of the inclusion and none of the exclusion criteria will be enrolled into the study. The intended coronary intervention is then carried out under mechanical circulatory support by the Investigational Device. This device is inserted through a sheath that has been deployed through a femoral puncture, following crimping of the Impella ECP. After proper placement and wireless passage of the aortic valve, the device pumps blood from the left ventricle into the aorta. Once the interventional procedure is completed, the device is weaned and removed. Subjects will be followed up until 30 days post intervention.

The primary and secondary end points will be summarized and presented without formal statistical testing. Safety will be assessed by the rate of composite Major Device-Related Adverse Events, evaluated at the end of the HRPCI procedure. Feasibility is defined as the successful delivery, initiation and maintenance of sufficient hemodynamic support to increase in or maintenance the MAP at physiologic levels (> 60 mmHg), evaluated up to the end of procedure.

Tipo di studio

Interventistico

Iscrizione (Stimato)

100

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Massachusetts
      • Boston, Massachusetts, Stati Uniti, 02111
        • Tufts Medical Center
    • Michigan
      • Detroit, Michigan, Stati Uniti, 48202
        • Henry Ford Hospital
      • Detroit, Michigan, Stati Uniti, 48236
        • Henry Ford Health St. John Hospital
    • New Jersey
      • Paramus, New Jersey, Stati Uniti, 07652
        • The Valley Hospital
    • Ohio
      • Cincinnati, Ohio, Stati Uniti, 45219
        • The Christ Hospital

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 90 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  1. Age ≥ 18 years and ≤ 90 years
  2. Subject has signed the informed consent
  3. Scheduled for an elective or urgent high risk percutaneous coronary intervention with hemodynamic support

Exclusion Criteria:

  1. Aortic valve disease that is anticipated to be prohibitive to Impella ECP crossing, including greater than mild aortic stenosis
  2. Previous aortic valve replacement or reconstruction
  3. Thrombus in left ventricle
  4. Subjects with known aortic vessel disease or with aortic dissection
  5. Any contraindication that precludes placing an Impella including aortic, iliac or femoral disease such as tortuosity, extensive atherosclerotic disease or stenosis
  6. Prior stroke with any permanent neurologic deficit or any prior intracranial hemorrhage or any prior subdural hematoma or known intracranial pathology pre-disposing to intracranial bleeding, such as an arteriovenous malformation or mass
  7. Cardiogenic shock or acutely decompensated pre-existing chronic heart failure. Cardiogenic shock is defined as: systemic hypotension (systolic BP <90 mmHg or the need for inotropes/pressors to maintain a systolic BP >90 mmHg) plus one of the following: any requirement for pressors/inotropes prior to arrival at the catheterization laboratory, clinical evidence of end-organ hypoperfusion or use of IABP or any other circulatory support device
  8. Infection of the proposed procedural access site or suspected systemic active infection, including any fever
  9. Subject has previously been symptomatic with or hospitalized for COVID-19 unless he/she has been discharged (if hospitalized) and asymptomatic for ≥8 weeks and has returned to his/her prior baseline (pre-COVID) clinical condition
  10. Known contraindication to heparin (i.e., heparin-induced thrombocytopenia), contrast media or Study-required medication(s) (i.e., aspirin)
  11. Platelet count <75k, bleeding diathesis, coagulopathy or unwilling to receive blood transfusions
  12. Subject is on dialysis
  13. Suspected or known pregnancy
  14. Subject has other medical, social or psychological problems that, in the opinion of the Investigator, compromises the subject's ability to give written informed consent and/or to comply with study procedures
  15. Participation in the active treatment or follow-up phase of another clinical study of an investigational drug or device which has not reached its primary endpoint
  16. Subject belongs to a vulnerable population [Vulnerable subject populations are defined as individuals with mental disability, persons in nursing homes, children, impoverished persons, homeless persons, nomads, refugees and those permanently incapable of giving informed consent. Vulnerable populations also may include members of a group with a hierarchical structure such as university students, subordinate hospital and laboratory personnel, employees of the Sponsor, members of the armed forces and persons kept in detention]

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Fattibilità del dispositivo
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Soggetti che ricevono Impella ECP

Subjects will receive the Impella ECP prior to high-risk percutaneous intervention. Device escalation or early termination of the study will be allowed for subjects as deemed necessary by the treating physician. Subjects will be followed until 30-days post-intervention.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Feasibility: successful hemodynamic support
Lasso di tempo: through end of procedure, 1 day

The feasibility assessment is defined as the successful delivery, initiation and maintenance of sufficient hemodynamic support to increase in or maintenance the MAP at physiologic levels (> 60 mmHg)

through end of procedure, 1 day
Safety: Major Device-Related Adverse Events
Lasso di tempo: through end of procedure, 1 day

The rate of composite Major Device-Related Adverse Events

through end of procedure, 1 day

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Technical Success
Lasso di tempo: through end of procedure, 1 day

The ability to complete the entire Impella ECP delivery procedure and pump initiation without device malfunction.

through end of procedure, 1 day
Procedural Success
Lasso di tempo: through end of procedure, 1 day

Technical success with a sufficient flow generation by the pump in order to increase or maintain MAP during the interventional procedure.

through end of procedure, 1 day
Rate of each individual Major Device-Related Adverse Event
Lasso di tempo: through end of study, 30 days

The rate of each individual Major Device-Related Adverse Event.

through end of study, 30 days
Rate of composite Major Device-Related Adverse Events
Lasso di tempo: through end of study, 30 days

The rate of composite Major Device-Related Adverse Events.

through end of study, 30 days

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Investigatori

  • Direttore dello studio: Seth Bilazarian, MD, Abiomed Inc.
  • Investigatore principale: Amir Kaki, MD, Ascension St. John Hospital
  • Direttore dello studio: Navin Kapur, MD, Abiomed Inc.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

9 ottobre 2020

Completamento primario (Stimato)

31 ottobre 2026

Completamento dello studio (Stimato)

31 ottobre 2026

Date di iscrizione allo studio

Primo inviato

13 luglio 2020

Primo inviato che soddisfa i criteri di controllo qualità

17 luglio 2020

Primo Inserito (Effettivo)

20 luglio 2020

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

21 settembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

17 settembre 2026

Ultimo verificato

1 luglio 2026

Maggiori informazioni

Termini relativi a questo studio

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Sì

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .