- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT05686915
MARS MRI in PTA di revisione con testa femorale in ceramica e manicotto in titanio
Sequenza RM di riduzione degli artefatti metallici nell'artroplastica totale dell'anca di revisione con testa femorale in ceramica e manicotto in titanio
Revision total hip replacement using a ceramic head utilizes a titanium sleeve which introduced another articulation into the system that may lead to a local soft tissue reaction. The purpose of this study is to determine the frequency, size and types of MRI documented local tissue reactions in individuals doing well after a revision total hip replacement and ceramic bearing surface that utilizes a titanium sleeve.
Panoramica dello studio
Stato
Condizioni
Descrizione dettagliata
Metal-on-metal total hip arthroplasty (THA) were heralded as a solution for two of the most common problems in hip arthroplasty in the last decade, instability and osteolysis. Unfortunately, their failures have led to diminished enthusiasm for this bearing surface. Adverse local tissue reactions (ATLRs) have been well documented as a means of pain and failure in this population. A recent report revealed that the most commonly used bearing surface in total hip arthroplasty, metal-on-polyethylene, may have up to a 28% incidence of MRI abnormalities in asymptomatic hips. Revision THA using a ceramic head utilizes a titanium sleeve which introduced another articulation into the system that may lead to a local soft tissue reaction. The purpose of this study is to determine the frequency, size and types of MRI documented local tissue reactions in asymptomatic individuals after a revision THA and ceramic bearing surface that utilizes a titanium sleeve. To our knowledge, this has not been studied previously and may provide important baseline features of this diagnostic tool with this particular bearing surface. We hypothesize that there will be fluid collections in a small but clinically significant portion of asymptomatic patients.
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
Colorado
-
Denver, Colorado, Stati Uniti, 80210
- Colorado Joint Replacement
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Patients who received a revision total hip surgery utilizing a ceramic femoral head with a titanium sleeve
Descrizione
Inclusion Criteria:
- Patients who received a revision total hip surgery utilizing a ceramic femoral head with a titanium sleeve
- Patient whose age ranges from 18-99
- Patients who are not experiencing groin pain, thigh pain, or pain with ROM of the hip
- Patients who are at least 2 years after a revision THA
- Acetabular implant (cup) was placed in the appropriate position
- Patients with a Harris Hip Score of >90
Exclusion Criteria:
- Patients who do not meet the above criteria
- Patients unable to have an MRI (i.e. pacemaker, metal implants or issues with claustrophobia requiring sedation)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: CASE_ONLY
- Prospettive temporali: PROSPECTIVE
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
Revision Total Hip Arthroplasty
Patients who received a revision total hip surgery utilizing a ceramic femoral head with a titanium sleeve |
metal artifact reduction sequence (MARS) MRI to assess for fluid collections, ATLRs or other abnormalities Labs to look at titanium levels in blood Labs to look at cobalt levels in blood Labs to look at chromium levels in blood |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
MARS MRI abnormalities
Lasso di tempo: 2 Years Post Revision Total Hip Replacement
|
Local Tissue Reactions or Fluid collections on the MARS MRI Scan |
2 Years Post Revision Total Hip Replacement
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Titanium Lab Value
Lasso di tempo: 2 Years Post Revision Total Hip Replacement
|
Titanium levels in blood |
2 Years Post Revision Total Hip Replacement
|
|
Chromium Lab Value
Lasso di tempo: 2 Years Post Revision Total Hip Replacement
|
Chromium levels in blood |
2 Years Post Revision Total Hip Replacement
|
|
Cobalt Lab Value
Lasso di tempo: 2 Years Post Revision Total Hip Replacement
|
Cobalt levels in blood |
2 Years Post Revision Total Hip Replacement
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Jason M Jennings, MD, Colorado Joint Replacement
Pubblicazioni e link utili
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- 1969400
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .