Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Säkerhet och effektivitet hos HIT Reverse HRS

19 november 2026 uppdaterad av: Hip Innovation Technology

Säkerhet och effektivitet hos höftledsinnovationsteknologin omvända höftproteser vid primär total höftprotesplastik: en pivotal studie

The purpose of this study is to determine if the use of the HIT Reverse Hip Replacement System is safe and effective in patients undergoing total hip replacement. We will determine whether it is safe and effective by comparing it to the control devices.

Studieöversikt

Detaljerad beskrivning

This is a randomized, controlled, multi-center clinical trial. Subjects meeting inclusion and exclusion criteria will be recruited from patients undergoing primary THA at up to 20 investigational sites. Subjects in the Experimental Arm will receive the Investigational Device. Subjects in the Control Arm will receive one of the already-marketed semi constrained uncemented hip systems using a metal on highly cross-linked polyethylene (XLPE) or ceramic-on-XLPE bearing combination. The following hip systems will be eligible for subjects in the Control Arm:

  • DePuy Synthes CORAIL® or DePuy Synthes ACTIS™ Total Hip System in combination with DePuy Synthes PINNACLE™ Complete Acetabular Hip System;
  • Zimmer Biomet Taperloc®, Zimmer Z1™ Cementless Femoral Hip Stem System or Zimmer Biomet AVENIR® Complete Hip System in combination with Zimmer Biomet G7® Acetabular System;
  • Stryker Accolade® II femoral stem in combination with Stryker Trident® II acetabular cup;
  • Smith & Nephew ANTHOLOGY® Total Hip System in combination with Smith & Nephew R3® Acetabular System.

Surgery, post-surgical care, and rehabilitation will be per standard of care (SOC) for both arms.

Studietyp

Interventionell

Inskrivning (Beräknad)

288

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

Studieorter

    • Florida
      • Miami, Florida, Förenta staterna, 33186
        • Rekrytering
        • Miami Institute for Joint Reconstruction
        • Huvudutredare:
          • Arturo Corces
        • Kontakt:
      • Tampa, Florida, Förenta staterna, 33614
        • Rekrytering
        • Advent Health Hospital, Carrollwood
        • Kontakt:
        • Huvudutredare:
          • Steven Lyons
      • Tampa, Florida, Förenta staterna, 33615
        • Rekrytering
        • Tampa General Health / Florida Orthopedic Institute
        • Kontakt:
        • Huvudutredare:
          • Michael Miranda, DO
    • Maryland
      • Baltimore, Maryland, Förenta staterna, 21215
        • Avslutad
        • LifeBridge Health Rubin Institute for Advanced Orthopedics
    • New Jersey
      • Somers Point, New Jersey, Förenta staterna, 08244
    • Ohio
      • New Albany, Ohio, Förenta staterna, 43054

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

50 år till 75 år (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Beskrivning

Inclusion Criteria:

  • Patient requires primary THA due to NIDJD or any of its composite diagnoses such as osteoarthritis, avascular necrosis, posttraumatic arthritis, slipped capital epiphysis, fracture of the pelvis, and diastrophic variant requiring unilateral primary THA.
  • Patient is between 50 (inclusive) and 75 (inclusive) years of age at the time of enrollment.
  • Patient has preoperative medical clearance and is free from or treated for medical conditions that would pose excessive operative risk.
  • Patient has a signed and dated Informed Consent Form (ICF).
  • Patient is willing and able to participate in required follow-up visits at the investigational site and to complete study procedures and questionnaires.

Exclusion Criteria:

  • Patient has received earlier THA, hemi-arthroplasty, or fusion in the contralateral hip in the last 24 months.
  • Patient has received earlier THA, hemi-arthroplasty, or fusion in the contralateral hip more than 24 months ago and has a contralateral hip-specific pain rating of ≥2 on a Numeric Rating Scale 0-10.
  • Patient needs bilateral hip replacement or has a planned THA on the contralateral hip joint in the next 24 months.
  • Patient needs knee arthroplasty or has a planned total knee arthroplasty in the next 24 months.
  • Patient has a known allergy to titanium and/or XLPE.
  • Patient has known metal sensitivities to cobalt chromium (CoCr).
  • Patient has a history of septic arthritis in the index joint.
  • Patient has insufficient acetabular or femoral bone stock in which good anchorage of the implants is unlikely or impossible.
  • Patient has total or partial absence of the muscular or ligamentous apparatus.
  • Patient has known moderate to severe renal insufficiency.
  • Patient has vascular insufficiency, muscular atrophy, or neuromuscular disease in either leg (based on the Investigator's judgment).
  • Patient has a deformity of the affected limb or significant anatomic variance of the affected hip.
  • Patient has an active malignancy or history of invasive malignancy within the last 5 years, except for superficial basal cell carcinoma or squamous cell carcinoma of the skin that has been definitively treated. Patients with carcinoma in situ of the uterine cervix definitively treated more than 1 year prior to enrollment may enter the study.
  • Patient has Paget's disease, Charcot-Marie-Tooth disease, or osteomalacia.
  • Patient has an inflammatory DJD including any of its composite diagnoses: rheumatoid arthritis, systemic lupus erythematosus, pigmented villonodular synovitis, juvenile rheumatoid arthritis, and other arthritic processes of inflammatory or autoimmune etiology.
  • Patient has any condition that would interfere with self-assessment of pain, function, or quality of life (QoL) required for patient-reported outcomes during the study (based on the Investigator's judgment).
  • Patient has a Body Mass Index (BMI) of 40 or higher.
  • Patient has an active infection (e.g., hepatitis, Acquired Immune Deficiency Syndrome (AIDS), AIDS-related Complex (ARC)) that is systemic or at the site of the intended surgery.
  • Patient is currently participating in any investigational study not related to this study's preoperative or postoperative care.
  • Patient is currently pregnant or is planning to become pregnant during the study.
  • Patient is a competitive or professional athlete.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Behandling
  • Tilldelning: Randomiserad
  • Interventionsmodell: Parallellt uppdrag
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Experimentell: Experimental Arm - HIT Reverse HRS

Subjects in the Experimental Arm will receive the HIT Reverse HRS Investigational Device. Implantation of the Investigational Device is performed using standard surgical procedures for THA, as described in the Instructions for Use (IFU). The control hip systems will be implanted in accordance with their respective IFU, which are also in line with standard surgical approaches for THA.

Implantation of the Investigational Device is performed using standard surgical procedures for THA, as described in the Instructions for Use (IFU). The control hip systems will be implanted in accordance with their respective IFU, which are also in line with standard surgical approaches for THA.

Andra namn:
  • TRYCK Reverse HRS
Aktiv komparator: Control Arm

Subjects in the Control Arm will receive one of the already-marketed semi- constrained uncemented hip systems using a metal-on-highly-cross-linked polyethylene (XLPE) or ceramic-on-XLPE bearing combination.

Control Arm subjects will receive one of the already-marketed semi-constrained uncemented hip systems using a metal-on-XLPE or ceramic-on-XLPE bearing combination.

  • DePuy Synthes CORAIL® or DePuy Synthes ACTIS™ Total Hip System in combination with DePuy Synthes PINNACLE™Complete Acetabular Hip System.
  • Zimmer Biomet Taperloc®, Zimmer Z1™ Cementless Femoral Hip Stem System or Zimmer Biomet AVENIR® Complete Hip System in combination with Zimmer Biomet G7® Acetabular System.
  • Stryker Accolade® II femoral stem in combination with Stryker Trident® II acetabular cup.
  • Smith & Nephew ANTHOLOGY® Total Hip System in combination with Smith & Nephew R3® Acetabular System
Andra namn:
  • Depuy Synthes Corail® eller DePuy Synthes Actis ™ Totalt höftsystem i kombination med DePuy Synthes Pinnacle ™ Komplett acetabulärt höftsystem
  • Zimmer Biomete Taperloc® eller Zimmer Biomet Avenir® Komplett höftsystem i kombination med Zimmer Biomet G7® Acetabular System
  • Stryker Accolade® II Femoral STEM i kombination med Stryker Trident® II Acetabular Cup
  • Smith & Nephew Anthology® Total Hip System i kombination med Smith & Nephew R3® Acetabular System
  • Zimmer Z1 ™ cementlöst femoral höftstamsystem

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
OHS of 36 or more at the 2-year follow-up visit
Tidsram: 24 months

The Oxford Hip Score (OHS) is a 12-item patient-reported outcome measure designed and developed to assess function and pain in patients undergoing hip replacement surgery. It ranges from 0 (poor) to 48 (best).

24 months
Change in OHS of 12 or more at the 2-year follow-up visit compared to baseline.
Tidsram: 24 months

The Oxford Hip Score (OHS) is a 12-item patient-reported outcome measure designed and developed to assess function and pain in patients undergoing hip replacement surgery. It ranges from 0 (poor) to 48 (best).

24 months
Radiologic success at the 2-year follow-up
Tidsram: 24 months

Defined as

  • No radiolucencies greater than 2 mm in 50% or more of the cup or stem zones;
  • No femoral or acetabular subsidence greater than or equal to 5 mm from baseline;
  • No acetabular cup inclination change greater than 4 degrees from baseline.
24 months
Absence of revision at the 2-year follow-up visit
Tidsram: 24 months

No reoperations that led to removal or replacement of any of the acetabular or femoral components.

24 months

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Change in OHS compared to baseline at all follow-up visits.
Tidsram: 24 months

The Oxford Hip Score (OHS) is a 12-item patient-reported outcome measure designed and developed to assess function and pain in patients undergoing hip replacement surgery. It ranges from 0 (poor) to 48 (best).

24 months
Change in HHS compared to baseline at all follow-up visits.
Tidsram: 24 months

The Harris Hip Score (HHS) is a clinician-based 10-item questionnaire used to evaluate the results of hip surgery. It is comprised of 4 sub-sections yielding a maximum possible score of 100 points collectively, including pain (44 points), function (47 points), absence of deformity (4 points), and range of motion (5 points).

Measured as Cohen's effect size, the improvements of THA are in the range of 3 and higher (Singh et al., 2016). The traditional categorization of HHS is: < 70, poor; 70-79, fair; 80-89, good; and 90-100, excellent.

24 months

Andra resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Exploratory Endpoints: OHS at all follow-up visits
Tidsram: 10 year

The Oxford Hip Score (OHS) is a 12-item patient-reported outcome measure designed and developed to assess function and pain in patients undergoing hip replacement surgery. It ranges from 0 (poor) to 48 (best).

10 year
Exploratory Endpoints: HHS sub-scores (Pain, Function, Absence of Deformity, Range of Motion) at all follow-up visits.
Tidsram: 10 year

The Harris Hip Score (HHS) is a clinician-based 10-item questionnaire used to evaluate the results of hip surgery. It is comprised of 4 sub-sections yielding a maximum possible score of 100 points collectively, including pain (44 points), function (47 points), absence of deformity (4 points), and range of motion (5 points).

Measured as Cohen's effect size, the improvements of THA are in the range of 3 and higher (Singh et al., 2016). The traditional categorization of HHS is: < 70, poor; 70-79, fair; 80-89, good; and 90-100, excellent.

10 year
Exploratory Endpoints: Device survivorship
Tidsram: 10 year

Device survivorship is measured as a cardinal event. Any reoperation in which the entire device or part of the device has been removed or replaced will be defined as a device revision.

10 year
Exploratory Endpoints: Radiographic evaluation of linear penetration of the femoral head at the 2-year follow-up visit.
Tidsram: 10 year

This study requires anteroposterior (AP)-pelvis and lateral (frog-leg or Lauenstein position) views obtained in the supine position on all subjects. An additional AP-hip image will be needed only if the AP-pelvis cannot provide a complete implant image. Radiographs will be obtained at the immediate postoperative follow-up (AP-pelvis only), and at the 6-week, 6-month, 1-year, 2-year, 3-year, 4-year, 5-year, and 10-year follow-up visits. Radiographs will be transferred to the Central Radiology Lab for processing and evaluation by an independent radiologist.

10 year
Exploratory Endpoints: Metal ion level assessment of titanium, cobalt, and chromium.
Tidsram: 10 year

All subjects will have baseline metal ion level (Ti, Co, and Cr) identified before study THA. Further, all subjects will be monitored for metal ions (Ti, Co, and Cr) at 1-, 2-, 3-, 4-, 5-, 7-, and 10-year follow-up visits.

10 year
Exploratory Endpoints: Subject Satisfaction with Outcome.
Tidsram: 10 year

Subject Satisfaction with Outcome will be evaluated at the 1, 2-, 3-, 4- 5-, 7- and 10-year follow-up visits using a 4-point ordinal scale. The questionnaire will ask subjects how satisfied they are with the outcome of the surgery. The available answers will include: Very Satisfied (4); Somewhat Satisfied (3); Somewhat Dissatisfied (2); and Very Dissatisfied (1).

10 year

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Publikationer och användbara länkar

Den som ansvarar för att lägga in information om studien tillhandahåller frivilligt dessa publikationer. Dessa kan handla om allt som har med studien att göra.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

15 juli 2022

Primärt slutförande (Beräknad)

16 september 2030

Avslutad studie (Beräknad)

16 september 2038

Studieregistreringsdatum

Först inskickad

20 april 2022

Först inskickad som uppfyllde QC-kriterierna

27 april 2022

Första postat (Faktisk)

2 maj 2022

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

24 november 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

19 november 2026

Senast verifierad

1 november 2026

Mer information

Termer relaterade till denna studie

Andra studie-ID-nummer

  • HIT-002

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Ja

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera