Evaluation of Glycemic Control and Quality of Life in Adults With Type 1 Diabetes During Continuous Glucose Monitoring When Switching to Insulin Glargine 300 U/mL (FUTURE-GLARE)
Evaluation of Glycemic Control and Quality of Life in Adults With Type 1 Diabetes During Continuous Glucose Monitoring When Switching to Insulin Glargine 300 U/mL: A FUTURE Substudy
Retrospective multicenter study analyzing data gathered during the FUTURE study (S59342) to assess the effect of using Insulin Glargine 300 U/mL (Gla-300) on measures of diabetes control and quality of life.
Of the FUTURE participants, data about the type of insulin the participants used will be gathered. On the basis of these data participants will be divided in two groups (control or investigational).
Change in glycemic control and quality of life from before to after the switch to Gla-300 (investigational group) will be compared to the change of glycemic control and quality of life of the FUTURE participants who did not switch to Gla-300 (control group).
The FUTURE study was a 24-month during multicenter observational cohort study analyzing data on the use of the Abbott Freestyle Libre in people with diabetes. Data were gathered during standard clinical follow-up, and from questionnaires that were presented to the participants at defined time points.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
-
Aalst, Belgique, 9300
- Onze Lieve Vrouw Ziekenhuis Aalst
-
Edegem, Belgique, 2650
- Universitair Ziekenhuis Antwerpen
-
Leuven, Belgique, 3000
- Universitaire Ziekenhuizen Leuven
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Investigational group
Inclusion Criteria:
- participant in the FUTURE study
- diagnosed with type 1 diabetes ≥3 months before start of the FUTURE study
- use of insulin pens for the entirety of the FUTURE study
- used Insulin Detemir (Levemir®), Insulin Glargine 100 U/mL (Lantus®) or an equivalent as basal insulin before switch to Gla-300 (Toujeo®)
- switched to Gla-300 (Toujeo®) during the FUTURE study for a sufficient amount of time (at least two consecutive diabetes consultations = 8 months)
Exclusion Criteria:
- use of Fast-acting insulin aspart (Fiasp®) before or after switch to Gla-300
- not using bolus insulin (only basal insulin)
- for women: pregnant or planning pregnancy during the FUTURE study
- Control group
Inclusion Criteria:
- participant in the FUTURE study for at least 18 months
- diagnosed with type 1 diabetes ≥3 months before start of the FUTURE study
- use of insulin pens for the entirety of the FUTURE study
- use Insulin Detemir (Levemir®), Insulin Glargine 100 U/mL (Lantus®) or an equivalent as basal insulin during the entirety of the FUTURE study
Exclusion Criteria:
- use of Fast-acting insulin aspart (Fiasp®)
- not using bolus insulin (only basal insulin)
- for women: pregnant or planning pregnancy during the FUTURE study
- switch to Gla-300 (Toujeo®) or Insulin Degludec (Tresiba®) before 18 months in FUTURE study (if switched after 18 months, only data up to switch to Gla-300 [Toujeo®] or Insulin Degludec [Tresiba®] will be used for this control participant)
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: Cas-témoins
- Perspectives temporelles: Rétrospective
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
---|---|
investigational group
Participants of the FUTURE study who switched during the study to Gla-300
|
Switch during standard routine care to Gla-300.
|
control group
Participants of the FUTURE study who did not switch to Insulin Gla-300
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
Time in range (TIR, 70-180 mg/dL)
Délai: maximum 24 months
|
The difference in evolution of TIR (70-180 mg/dL, averaged per month) over 24 hours since switch to Gla-300
|
maximum 24 months
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
HbA1c
Délai: maximum 24 months
|
difference in HbA1c
|
maximum 24 months
|
Time in range (TIR, 70-180 mg/dL)
Délai: maximum 24 months
|
difference in TIR (70-180 mg/dL, averaged per month) from 6 am to 10 pm, and from 10 pm to 6 am
|
maximum 24 months
|
Hypoglycemia
Délai: maximum 24 months
|
difference in time in hypoglycemia (<54 mg/dL, <70 mg/dL, ≥54-<70 mg/dL; averaged per month) over 24 hours, from 6 am to 10 pm, and from 10 pm to 6 am
|
maximum 24 months
|
Hyperglycemia
Délai: maximum 24 months
|
difference in time in hyperglycemia (>180 mg/dL, >250 mg/dL, >180-≤250 mg/dL; averaged per month) over 24 hours, from 6 am to 10 pm, and from 10 pm to 6 am
|
maximum 24 months
|
Mean glycemia
Délai: maximum 24 months
|
difference in mean glucose (averaged per month) over 24 hours, from 6 am to 10 pm, and from 10 pm to 6 am
|
maximum 24 months
|
Glycemic variability
Délai: maximum 24 months
|
difference in glycemic variability (standard deviation, coefficient of variation; averaged per month) over 24 hours, from 6 am to 10 pm, and from 10 pm to 6 am
|
maximum 24 months
|
Quality of life measured by the Short Form Health Survey 36-item (SF-36) version 2 questionnaire
Délai: maximum 24 months
|
Quality of life measured by the Short Form Health Survey 36-item (SF-36) version 2 questionnaire (scale: 0 (low quality of life) - 100 (high quality of life))
|
maximum 24 months
|
Fear of hypoglycemia measured by the Hypoglycemia Fear Survey, version II (HFS-II) questionnaire, worry
Délai: maximum 24 months
|
Fear of hypoglycemia measured by the Hypoglycemia Fear Survey, version II (HFS-II) questionnaire, worry (scale: 0 (not worried) - 72 (very worried))
|
maximum 24 months
|
Distress due to diabetes measured by the Problem Areas In Diabetes survey, short form (PAID-SF) questionnaire
Délai: maximum 24 months
|
Distress due to diabetes measured by the Problem Areas In Diabetes survey, short form (PAID-SF) questionnaire (scale: 0 (no distress) - 20 (very distressed))
|
maximum 24 months
|
Treatment satisfaction measured by the Diabetes Treatment Satisfaction Questionnaire, status (DTSQs)
Délai: maximum 24 months
|
Treatment satisfaction measured by the Diabetes Treatment Satisfaction Questionnaire, status (DTSQs) (scale: 0 (low satisfaction) - 36 (high satisfaction))
|
maximum 24 months
|
Autres mesures de résultats
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
Insulin dose
Délai: maximum 24 months
|
difference in insulin dose (basal, bolus and total)
|
maximum 24 months
|
Body mass index
Délai: maximum 24 months
|
difference in body mass index (BMI)
|
maximum 24 months
|
Severe hypoglycemia rate
Délai: maximum 24 months
|
difference in self-reported severe hypoglycemic events
|
maximum 24 months
|
Hypoglycemic coma rate
Délai: maximum 24 months
|
difference in self-reported hypoglycemic comas
|
maximum 24 months
|
Hospitalization
Délai: maximum 24 months
|
difference in hospitalizations due to hypoglycemia or ketoacidosis
|
maximum 24 months
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Pieter Gillard, MD, PhD, Universitaire Ziekenhuizen KU Leuven
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- S65399
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .
Essais cliniques sur Diabète de type 1
-
Eledon PharmaceuticalsRetiréDiabète sucré de type 1 fragileÉtats-Unis
-
Ain Shams UniversityInconnueDiabète sucré de type 1 avec hypoglycémie | diabète de type 1Egypte
-
National Institute of Allergy and Infectious Diseases...PPD; Rho Federal Systems Division, Inc.; Immune Tolerance Network (ITN)ComplétéDiabète sucré de type 1 | DT1 | DT1 | Diabète sucré de type 1 d'apparition récenteÉtats-Unis, Australie
-
Medical College of WisconsinRecrutementDiabète de type 1 | Diabète sucré de type 1 | diabète de type 1États-Unis
-
Spiden AGDCB Research AGRecrutementDiabète sucré de type 1 | Diabète sucré de type 1 avec hypoglycémie | Diabète sucré de type 1 avec hyperglycémieSuisse
-
Shanghai Changzheng HospitalRecrutementDiabète sucré de type 1 fragileChine
-
Instytut Diabetologii Sp. z o.o.National Center for Research and Development, Poland; Nalecz Institute of...InconnueDiabète sucré de type 1 avec hyperglycémie | Diabète sucré de type 1 avec hypoglycémiePologne
-
Capillary Biomedical, Inc.ComplétéDiabète sucré, type 1 | Diabète de type 1 | Diabète sucré de type 1 | Diabète sucré, dépendant de l'insuline, 1Australie
-
Poznan University of Medical SciencesInconnueDiabète sucré de type 1 | Rémission du diabète de type 1 | Complications chroniques du diabètePologne
-
Capillary Biomedical, Inc.RésiliéDiabète de type 1 | Diabète sucré de type 1 | Diabète sucré, type I | Diabète sucré, dépendant de l'insuline, 1 | IDDML'Autriche
Essais cliniques sur Insulin Glargine 300 UNT/ML [Toujeo]
-
Changhua Christian HospitalRecrutementAcidocétose diabétique | Crise hyperglycémique dans le diabète sucré | Syndrome hyperglycémique hyperosmolaire non cétosiqueTaïwan
-
Mira ZuidgeestSanofi; Innovative Medicines Initiative; IMI Trials@Home consortiumRecrutementDiabète sucré, Type 2Royaume-Uni, Danemark, Allemagne
-
SanofiRésiliéDiabète sucré de type 2 | Insuffisance rénaleÉtats-Unis, Tchéquie, Hongrie, Pologne, Serbie
-
SanofiComplétéDiabète sucré de type 1France, Tchéquie, Chili, Israël, Espagne, Hongrie, Mexique, Serbie, Japon, Canada, Brésil, Suède, Danemark, Argentine, États-Unis, Bulgarie, Allemagne, Italie, Lettonie, Macédoine du Nord, Pologne, Roumanie, Fédération Russe, Royaume-Uni
-
SanofiComplétéDiabète sucré de type 1États-Unis, Porto Rico
-
SanofiComplétéDiabète sucré, Type 2États-Unis, Canada
-
SanofiComplétéDiabète sucré de type 1Turquie, Pays-Bas, Brésil, États-Unis, Allemagne, Hongrie, Royaume-Uni
-
SanofiRésilié