- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT04289870
Innoventric Trillium™ -stenttisiirteen ensimmäinen ihmisessä (FIH) -tutkimus
Tuleva, yksihaarainen, monikeskus, ensimmäinen ihmisessä (FIH) -tutkimus Innoventric Trillium™ -stenttisiirteen turvallisuuden ja suorituskyvyn arvioimiseksi vaikean kolmikulmaisen regurgitaation (TR) hoitoon
A prospective, single-arm, multi-center first-in-human (FIH) study to evaluate the safety and performance of the Innoventric Trillium™ Stent Graft System.
Twenty (20) patients in 8 investigational sites will be enrolled. All enrolled study patients will be assessed at baseline, during the procedure, at discharge, after 1 month, 3 months, 6 months, 1 year, 1.5 years, 2 years, and 3 years following the index procedure.
Tutkimuksen yleiskatsaus
Opintotyyppi
Ilmoittautuminen (Todellinen)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Aalst, Belgia
- OLVZ Aalst
-
Antwerp, Belgia
- ZNA
-
-
-
-
-
Barcelona, Espanja
- Hospital Clinic de Barcelona
-
Salamanca, Espanja
- Hospital Universitario de Salamanca
-
Vigo, Espanja
- Hospital Alvaro Cunqueiro, Hospital Universitario de Vigo
-
-
-
-
-
Petah Tikva, Israel, 4941492
- Rabin Medical Center
-
-
-
-
-
Bad Oeynhausen, Saksa, 32545
- Heart & Diabetes Center NRW
-
Berlin, Saksa
- Herzzentrum der Charité (DHZC)
-
Leipzig, Saksa
- Leipzig Heart Center
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
Enrolled patients must meet ALL the following criteria:
- Age >40 (no upper limit)
- Patient has clinically significant TR graded as severe based on the presence of systolic hepatic vein flow reversal, and VCW≥7mm or EROA≥40mm^2
- Symptomatic despite medical therapy; patient must be on diuretic therapy.
- Peak central venous pressure of ≥ 15mmHg
- The local site Heart Team determines that the patient is appropriate for transcatheter tricuspid intervention
- Patient is willing and able to comply with all specified study evaluations.
- Patient has NYHA functional classification of III or IV
- Patient is not eligible for standard-of-care surgical or interventional therapy assessed by the central heart team or has refused standard-of-care surgical and interventional therapy or has received standard-of-care TR therapy and remains symptomatic
- Patient understands the nature of the study and study requirements and is willing to provide written Informed Consent prior to any study-specific procedures.
Exclusion Criteria:
Patients will be excluded from participation if ANY of the following criteria apply:
-
Echocardiographic parameters (Any of the following):
I. LVEF < 20% II. Evidence of severe right ventricular dysfunction (e.g. right ventricular TAPSE < 13.0mm) III. IVC or SVC anatomy that precludes proper device deployment and function
-
Systolic Pulmonary Artery Pressure > 70mmHg
-
Severe aortic, mitral, and/or pulmonic valve stenosis and/or regurgitation
-
Active endocarditis within 90 days of the scheduled implant
-
Significant pericardial effusion
-
Intra-cardiac masses, thrombi, or vegetation
-
Thrombosis of the venous system
-
Space-consuming lesion in the heart or on the valves, thrombus, or microbial colonization of the valves
-
Untreated clinically significant coronary artery disease requiring immediate revascularization
-
MI or known unstable angina within 30 days prior to the index procedure
-
Any therapeutic invasive cardiac procedure within 30 days prior to the index procedure
-
Any prior cardiac surgery, within 3 months of the index procedure
-
Hemodynamic instability or treated with IV inotropes within 30 days of the index procedure
-
Severe uncontrolled hypertension (SBP ≥ 180 mmHg and/or DBP ≥ 110 mm Hg)
-
Severe uncontrolled hypotension (SBP≤80 mmHg and/or DBP≤40 mmHg)
-
Cerebrovascular Accident (CVA) within the past 90 days
-
Kidney dysfunction with estimated Glomerular Filtration Rate (eGFR) < 30 ml/min/1.73 m^2 or patient is on chronic dialysis
-
Significant frailty (i.e. Clinical Frailty Scale© (CFS) ≥ 7) within 90 days of the scheduled implant procedure
-
Chronic liver disease with a MELD score of 20 or greater
-
Chronic anemia (Hb < 9 g/L) not corrected by transfusion
-
Thrombocytopenia (Platelet count< 100,000/mm3) or thrombocytosis (Platelet count > 750,000/mm3)
-
Bleeding disorders or hypercoagulable state
-
Active peptic ulcer or active gastrointestinal (GI) bleeding within 90 days of the scheduled implant
-
Contraindication to anticoagulants or antiplatelet agents
-
Currently or history of IV drug use
-
Pregnant or lactating; or female of childbearing potential with a positive pregnancy test 24 hours before any study-related radiation exposure.
-
Inability to access the femoral vein with a 24 FR guide (e.g., DVT, occluded femoral veins).
-
Known allergy to stainless steel, nickel, titanium, PET or contrast agents that cannot be adequately pre-medicated.
-
Known hypersensitivity or contraindication to procedural medications which cannot be adequately managed medically
-
Impaired judgment
-
Undergoing emergent or urgent treatment for tricuspid insufficiency
-
Currently participating in another investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the endpoints of this study
-
Co-morbid condition(s) that, in the opinion of the Investigator, limit life expectancy to < 12 months
-
Cardiac cachexia
-
In the judgment of the Investigator, co-morbid condition(s) that could limit the patient's ability to participate in the study, including compliance with follow-up requirements, or that could impact the scientific integrity of the study
-
Patient is under guardianship
-
Presence of any prosthetic device in the SVC or IVC (excluding pace-maker, ICD and CRT leads)
-
Elevated inflammatory markers within 2 weeks of the scheduled procedure (e.g. CRP>1.5mg/dL).
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: Innoventric Trillium™ Stent Graft Single Arm
Single-arm, open label, multi-center study |
Trillium™ Stent Graft for Functional Tricuspid Valve Replacement |
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Safety Endpoint
Aikaikkuna: Evaluated immediately after intervention, discharge and 30 days
|
Rate of device or procedure-related MAEs and Freedom from unplanned surgery or re-intervention, due to life-threatening device or procedure failure |
Evaluated immediately after intervention, discharge and 30 days
|
|
Technical performance
Aikaikkuna: Evaluated immediately after intervention
|
Successful access, delivery, and retrieval of the Trillium delivery system, the device is anchored both in SVC and IVC. |
Evaluated immediately after intervention
|
|
Efficacy Endpoint
Aikaikkuna: Evaluated immediately after intervention
|
TR grade as measured on the device valves (Echocardiography), or by hepatic vein systolic backflow (Echocardiography), or reduction in peak central venous pressure (Invasive hemodynamic measurement). |
Evaluated immediately after intervention
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Safety Endpoint
Aikaikkuna: Assessment at 3-month, 6-month and 1-year
|
Composite of all device or procedure-related MAEs. |
Assessment at 3-month, 6-month and 1-year
|
|
Efficacy Endpoint
Aikaikkuna: Assessment at 30 days, 3-month, 6-month and 1-year
|
One or more of the following-
Or one or more of the following-
|
Assessment at 30 days, 3-month, 6-month and 1-year
|
Muut tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Other Endpoints
Aikaikkuna: Assessment at 30 days, 3-month, 6-month and 1-year
|
transthoracic echocardiography (TTE) will be performed to determine acceptable performance of the device defined as a reduction in hepatic vein systolic backflow to moderate (systolic blunting) or better. In addition, the tricuspid valve complex will be imaged to capture the following parameters for comparison to baseline: Page 46 of 118 -Confidential-
The following clinical and laboratory parameters will be captured for comparison to baseline values:
|
Assessment at 30 days, 3-month, 6-month and 1-year
|
Yhteistyökumppanit ja tutkijat
Sponsori
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- CLD-001
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .